Arthroscopic Capsulotomy, Capsular Repair, and Capsular Plication of the Hip: Relation to Atraumatic Instability

Author(s):  
Benjamin G. Domb ◽  
Marc J. Philippon ◽  
Brian D. Giordano
2021 ◽  
Vol 9 (10) ◽  
pp. 232596712110400
Author(s):  
Anthony F. De Giacomo ◽  
Young Lu ◽  
Dong Hun Suh ◽  
Michelle H. McGarry ◽  
Michael Banffy ◽  
...  

Background: In hip arthroscopy, the best capsular closure technique to prevent microinstability in some patients while preventing overconstraints in other patients has yet to be determined. Purpose: To evaluate the biomechanical effects of capsular repair, capsular shift, and combination capsular shift and capsular plication for closure of the hip capsule. Study Design: Controlled laboratory study. Methods: Eight cadaveric hips (4 male and 4 female hips; mean age, 55.7 years) were evaluated in 7 conditions: intact, vented, capsulotomy, side-to-side repair, side-to-side repair with capsular plication (interval closure between iliofemoral and ischiofemoral ligaments), capsular shift repair, and capsular shift repair with plication. Measurements, via a 360° goniometer, included internal and external rotation with 1.5 N·m of torque at 5° of extension and 0°, 30°, 60°, and 90° of flexion. In addition, the degree of maximum extension with 5 N·m of torque and the amount of femoral distraction with 40 N and 80 N of force were obtained. Repeated-measures analysis of variance and Tukey post hoc analyses were used to analyze differences between capsular conditions. Results: At lower hip positions (5° of extension, 0° and 30° of flexion), there was a significant increase in external rotation and total rotation after capsulotomy versus the intact state ( P < .05). At all hip flexion angles, there was a significant increase in external rotation, internal rotation, and total rotation as well as a significant increase in maximum extension after capsulotomy versus capsular shift with plication ( P < .05 for all). At all flexion angles, both capsular closure with side-to-side repair (with or without plication) and capsular shift without capsular plication were able to restore rotation, with no significant differences compared with the intact capsule ( P > .05). Among repair constructs, there were significant differences in range of motion between side-to-side repair and combined capsular shift with plication ( P < .05). Conclusion: At all positions, significantly increased rotational motion was seen after capsulotomy. Capsular closure was able to restore rotation similar to an intact capsule. Combined capsular shift and plication may provide more restrained rotation for conditions of hip microinstability but may overconstrain hips without laxity. Clinical Relevance: More advanced closure techniques or a combination of techniques may be needed for patients with hip laxity and microinstability. At the same time, simple repair may suffice for patients without these conditions.


2021 ◽  
Vol 9 (1) ◽  
pp. 232596712096964
Author(s):  
Sumit Raniga ◽  
Joseph Cadman ◽  
Danè Dabirrahmani ◽  
David Bui ◽  
Richard Appleyard ◽  
...  

Background: Suture pullout during rehabilitation may result in loss of tension in the inferior glenohumeral ligament (IGHL) and contribute to recurrent instability after capsular plication, performed with or without labral repair. To date, the suture pullout strength in the IGHL is not well-documented. This may contribute to recurrent instability. Purpose/Hypothesis: A cadaveric biomechanical study was designed to investigate the suture pullout strength of sutures in the IGHL. We hypothesized that there would be no significant variability of suture pullout strength between specimens and zones. Additionally, we sought to determine the impact of early mobilization on sutures in the IGHL at time zero. We hypothesized that capsular plication sutures would fail under low load. Study Design: Descriptive laboratory study. Methods: Seven fresh-frozen cadaveric shoulders were dissected to isolate the IGHL complex, which was then divided into 18 zones. Sutures in these zones were attached to a linear actuator, and the resistance to suture pullout was recorded. A suture pullout strength map of the IGHL was constructed. These loads were used to calculate the load applied at the hand that would initiate suture pullout in the IGHL. Results: Mean suture pullout strength for all specimens was 61.6 ± 26.1 N. The maximum load found to cause suture pullout through tissue was found to be low, regardless of zone of the IGHL. Calculations suggest that an external rotation force applied to the hand of only 9.6 N may be sufficient to tear capsular sutures at time zero. Conclusion: This study did not provide clear evidence of desirable locations for fixation in the IGHL. However, given the low magnitude of failure loads, the results suggest the timetable for initiation of range-of-motion exercises should be reconsidered to prevent suture pullout through the IGHL. Clinical Relevance: From this biomechanical study, the magnitude of force required to cause suture pullout through the IGHL is met or surpassed by normal postoperative early range-of-motion protocols.


2015 ◽  
Vol 24 (2) ◽  
pp. 489-495 ◽  
Author(s):  
Michael H. Abdulian ◽  
Curtis J. Kephart ◽  
Michelle H. McGarry ◽  
James E. Tibone ◽  
Thay Q. Lee

2021 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Dillon C. O’Neill ◽  
Kelly M. Tomasevich ◽  
Alexander J. Mortensen ◽  
Joseph Featherall ◽  
Suzanna M. Ohlsen ◽  
...  

2019 ◽  
Vol 8 (11) ◽  
pp. e1353-e1359
Author(s):  
Thomas Alter ◽  
Kelechi R. Okoroha ◽  
Kyle N. Kunze ◽  
Edward C. Beck ◽  
Shane J. Nho

Sign in / Sign up

Export Citation Format

Share Document