scholarly journals SRF based versatile control technique for DVR to mitigate voltage sag problem in distribution system

2020 ◽  
Vol 11 (1) ◽  
pp. 99-108 ◽  
Author(s):  
Essam A. Al-Ammar ◽  
Azhar Ul-Haq ◽  
Ahsan Iqbal ◽  
Marium Jalal ◽  
Almas Anjum
2016 ◽  
Vol 818 ◽  
pp. 52-57 ◽  
Author(s):  
Faridullah Kakar ◽  
Abdullah Asuhaimi bin Mohd Zin ◽  
Mohd Hafiz bin Habibuddin

Voltage sag and harmonics are the most frequent power quality problems faced by industrial and commercial customers today. Situation has been aggravated by modern sensitive industrial equipments which introduce system harmonics due to their inherent V-I characteristics. In this paper, proportional integral (PI) control technique based dynamic voltage restorer (DVR) is implemented in power distribution system to suppress voltage sag and harmonics under linear, non-linear and induction motor load conditions. Real-time power distribution system and DVR test models are built in Matlab/Simulink software. Simulation results exhibit excellent PI control approach with effective performance yielding excellent voltage regulation.


2013 ◽  
Vol 341-342 ◽  
pp. 1363-1366
Author(s):  
Lang Bai ◽  
Le Yu

The evaluation results of power system are greatly influenced by the reliability parameters and uncertainty of system components. The connection number assessment model and an approach have been presented to assess the occurrence frequency due to voltage sags. The proposed method had been applied to a real distribution system. Compared with the interval number method, the simulation results have shown that this method is simple and flexible.


2012 ◽  
Vol 2012 ◽  
pp. 1-11 ◽  
Author(s):  
M. S. Ballal ◽  
H. M. Suryawanshi ◽  
T. Venkateswara Reddy

The basic power quality problems in the distribution network are voltage sag (dip), voltage flickering, and the service interruptions. STATCOM is a Flexible AC Transmission Systems (FACTS) technology device which can independently control the flow of reactive power. This paper presents the simulation and analysis of a STATCOM for voltage dip and voltage flickering mitigation. Simulations are carried out in MATLAB/Simulink to validate the performance of the STATCOM. A comparison between the six-pulse inverter and the five-level diode-clamped inverter is carried out for the performance of 66/11 KV distribution system.


Author(s):  
Wang Kexing ◽  
Song Zhengxiang ◽  
Chen Degui ◽  
Wang Jianhua ◽  
Geng Yingsan

Author(s):  
A. Sathik Basha ◽  
M. Ramasamy

Increased utilization of nonlinear loads in the power distribution system with profound integration of renewable energy requires improved power quality control. This paper proposes a Reformed Second Order Generalized Integrated (R-SOGI) control scheme for enhancing the output of the Dynamic Voltage Restorer (DVR) for the objective of achieving the desired sinusoidal voltage wave shape at the common point of services and harmonic reduction. The DVR incorporates a Solar Photovoltaic (SPV) system using the Z-source Inverter (ZSI), providing the necessary active power to mitigate the voltage sag/swell and power demand. ZSI offers step-down as well as step-up abilities, it makes the converters to operate in the conditions of shoot-through. Therefore, the application of ZSI-based DVR topology seems very promising. The compensating reference voltage is generated by the R-SOGI algorithm, which offers superior output under conditions for grid voltage irregularities, including voltage sag/swell and unbalanced and distorted utility grid voltages. In comparison to DVR based on the VSI voltage inverter (VSI), the response from ZSI-DVR to a reduction of voltage distortions and harmonics is investigated. An experimental SPV ZSI-DVR prototype is developed in the laboratory to check the effectiveness of the controller and is tested under balanced and unbalanced supply and dynamic load conditions.


Sign in / Sign up