Response to “Technical comments on “Oxic-settling-anoxic (OSA) process combined with 3,3′,4′,5-tetrachlorosalicylanilide (TCS) to reduce excess sludge production in the activated sludge system” by Fenxia Ye and Ying Li (doi:10.1016/j.bej.2010.01.001)”

2010 ◽  
Vol 50 (3) ◽  
pp. 152
Author(s):  
Fenxia Ye
2015 ◽  
Vol 73 (4) ◽  
pp. 734-739 ◽  
Author(s):  
C. L. Martins ◽  
V. F. Velho ◽  
S. R. A. Ramos ◽  
A. S. C. D. Pires ◽  
E. C. N. F. A. Duarte ◽  
...  

The aim of this study was to investigate the ability of the oxic-settling-anaerobic (OSA)-process and the folic acid addition applied in the activated sludge process to reduce the excess sludge production. The study was monitored during two distinct periods: activated sludge system with OSA-process, and activated sludge system with folic acid addition. The observed sludge yields (Yobs) were 0.30 and 0.08 kgTSS kg–1 chemical oxygen demand (COD), control phase and OSA-process (period 1); 0.33 and 0.18 kgTSS kg–1 COD, control phase and folic acid addition (period 2). The Yobs decreased by 73 and 45% in phases with the OSA-process and folic acid addition, respectively, compared with the control phases. The sludge minimization alternatives result in a decrease in excess sludge production, without negatively affecting the performance of the effluent treatment.


2004 ◽  
Vol 49 (10) ◽  
pp. 41-49 ◽  
Author(s):  
M. Böhler ◽  
H. Siegrist

Disposal of sewage sludge is forbidden and agricultural use of stabilized sludge will be banned in 2005 in Switzerland. The sludge has to be dewatered, dried, incinerated and the ashes disposed in landfills. These processes are cost intensive and lead also to the loss of valuable phosphate resources incorporated in the sludge ash. The implementation of processes that could reduce excess sludge production and recycle phosphate is therefore recommended. Partial ozonation of the return sludge of an activated sludge system reduces significantly excess sludge production, improves settling properties of the sludge and reduces bulking and scumming. The solubilized COD will also improve denitrification if the treated sludge is recycled to the anoxic zone. But ozonation will partly inhibit and kill nitrifiers and might therefore lead to a decrease of the effective solid retention time of the nitrifier, which reduces the safety of the nitrification. This paper discusses the effect of ozonation on sludge reduction, the operation stability of nitrification, improvement of denitrification and gives also an energy and cost evaluation.


2001 ◽  
Vol 44 (10) ◽  
pp. 203-208 ◽  
Author(s):  
G.-H. Chen ◽  
S. Saby ◽  
M. Djafer ◽  
H.-K. Mo

This paper presents three new approaches to reduce excess sludge production in activated sludge systems: 1) modification of conventional activated sludge process with insertion of a sludge holding tank in the sludge return line; 2) chlorination of excess sludge so as to minimize excess sludge production; and 3) utilization of a metabolic uncoupler, 3, 3′, 4′, 5-Tetrachlorosalicylanilide (TCS) to maximize futile activity of sludge microorganisms thereby leading to a reduction of sludge growth. Pilot study was carried out to evaluate this modified activated sludge process (OSA). It has been confirmed that the OSA process is effective in reducing excess sludge; particularly when the ORP level in the sludge holding tank was kept at -250 mV, more than 50% of the excess sludge was reduced. This process can maintain the effluent quality and even perform with a better sludge settleability than a conventional system. Experimental work on the second approach showed that chlorination treatment of excess sludge at a chlorine dose of 0.066 g Cl2/g MLSS reduced the excess sludge by 60%, while concentration of THMS was found below 200 ppb in the treated sludge. However, such sludge chlorination treatment sacrificed sludge settleability. Thus, it is not feasible to introduce the chlorination step to a conventional system. The third approach confirmed that addition of TCS could reduce sludge growth effectively if the TCS concentration is greater than 0.4 ppm. A 0.8-ppm concentration of TCS actually reduced excess sludge by 45%. It was also experimentally demonstrated that presence of TCS increases the portion of active sludge microorganisms over the entire microbial population.


2012 ◽  
Vol 2012 ◽  
pp. 1-8 ◽  
Author(s):  
B. Subha ◽  
M. Muthukumar

Sago industries effluent containing large amounts of organic content produced excess sludge which is a serious problem in wastewater treatment. In this study ozonation has been employed for the reduction of excess sludge production in activated sludge process. Central composite design is used to study the effect of ozone treatment for the reduction of excess sludge production in sago effluent and to optimise the variables such as pH, ozonation time, and retention time. ANOVA showed that the coefficient determination value (R2) of VSS and COD reduction were 0.9689 and 0.8838, respectively. VSS reduction (81%) was achieved at acidic pH 6.9, 12 minutes ozonation, and retention time of 10 days. COD reduction (87%) was achieved at acidic pH 6.7, 8 minutes of ozonation time, and retention time of 6 days. Low ozonation time and high retention time influence maximum sludge reduction, whereas low ozonation time with low retention time was effective for COD reduction.


Sign in / Sign up

Export Citation Format

Share Document