Immunodevice for simultaneous detection of two relevant tumor markers based on separation of different microparticles by dielectrophoresis

2011 ◽  
Vol 28 (1) ◽  
pp. 443-449 ◽  
Author(s):  
Javier Ramón-Azcón ◽  
Tomoyuki Yasukawa ◽  
Fumio Mizutani
2007 ◽  
Vol 53 (7) ◽  
pp. 1323-1329 ◽  
Author(s):  
Dianping Tang ◽  
Ruo Yuan ◽  
Yaqin Chai

Abstract Background: Methods based on magnetic bead probes have been developed for immunoassay, but most involve complicated labeling or stripping procedures and are unsuitable for routine use. Methods: We synthesized magnet core/shell NiFe2O4/SiO2 nanoparticles and fabricated an electrochemical magnetic controlled microfluidic device for the detection of 4 tumor markers. The immunoassay system consisted of 5 working electrodes and an Ag/AgCl reference electrode integrated on a glass substrate. Each working electrode contained a different antibody immobilized on the NiFe2O4/SiO2 nanoparticle surface and was capable of measuring a specific tumor marker using noncompetitive electrochemical immunoassay. Results: Under optimal conditions, the multiplex immunoassay enabled the simultaneous detection of 4 tumor markers. The sensor detection limit was <0.5 μg/L (or <0.5 kunits/L) for most analytes. Intra- and interassay imprecisions (CVs) were <4.5% and 8.7% for analyte concentrations >5 μg/L (or >5 kunits/L), respectively. No nonspecific adsorption was observed during a series of procedures to detect target proteins, and electrochemical cross-talk (CV) between neighboring sites was <10%. Conclusion: This immunoassay system offers promise for label-free, rapid, simple, cost-effective analysis of biological samples. Importantly, the chip-based immunosensor could be suitable for use in the mass production of miniaturized lab-on-a-chip devices and open new opportunities for protein diagnostics and biosecurity.


Nanoscale ◽  
2019 ◽  
Vol 11 (17) ◽  
pp. 8119-8123 ◽  
Author(s):  
Yiting Jiang ◽  
Yuguo Tang ◽  
Peng Miao

An innovative fluorescence method is developed for simultaneous detection of multiplex tumor markers based on a polydopamine nanosphere@silver nanocluster system.


2007 ◽  
Vol 53 (8) ◽  
pp. 1495-1502 ◽  
Author(s):  
Jie Wu ◽  
Feng Yan ◽  
Jinhai Tang ◽  
Chun Zhai ◽  
Huangxian Ju

Abstract Background: Automated and convenient multianalyte detection with high throughput is increasingly needed in clinical diagnosis. We developed a disposable 4-by-2 array for programmed simultaneous amperometric immunoassay of 4 tumor markers. Methods: We used a screen-printed technique, 1-step immobilization method, and flow injection technique. We immobilized carcinoembryonic antigen, α-fetoprotein, β-human choriogonadotropin, and carcinoma antigen 125 as model analytes in a redox mediator–grafted, biopolymer-modified, screen-printed carbon electrode array to capture corresponding horseradish peroxidase-labeled antibodies in competitive immunoreactions. The simultaneous multianalyte immunoassay was automatically carried out to amperometrically monitor the mediator-catalyzed enzymatic response to hydrogen peroxide, which decreased in proportion to the concentrations of analytes in samples. Results: The multianalyte immunosensor array had a throughput of 60 samples/h and allowed simultaneous detection of carcinoembryonic antigen, α-fetoprotein, β-human choriogonadotropin, and carcinoma antigen 125 in clinical serum samples with concentrations up to 188 μg/L, 250 μg/L, 266 IU/L, and 334 kIU/L, respectively. The detection limits (limits of the blank, mean of blank plus 3 SD) were 1.1 μg/L, 1.7 μg/L, 1.2 IU/L, and 1.7 kIU/L. The inter- and intraassay imprecision (CVs) of the immunosensor arrays were <7.8% and <9.0%, respectively. The immunosensor arrays were stable for 28 days. Conclusions: This newly constructed immunosensor array provides a simple, automated, simultaneous multianalyte immunoassay with high throughput, short analytical time, and sufficiently low detection limits for clinical application. This method offers the capability of miniaturizing the multianalyte detection device.


Nanoscale ◽  
2021 ◽  
Author(s):  
Yingying Zhong ◽  
xian Wang ◽  
Ruyan Zha ◽  
Chen Wang ◽  
Huijuan Zhang ◽  
...  

A single tumor marker may correspond to a variety of diseases, and a specific disease requires the joint detection of multiple tumor markers for improving the accuracy of diagnoses. An...


RSC Advances ◽  
2015 ◽  
Vol 5 (128) ◽  
pp. 105992-105998 ◽  
Author(s):  
Lihua Li ◽  
Dexiang Feng ◽  
Junqing Zhao ◽  
Zilin Guo ◽  
Yuzhong Zhang

Fluoroimmunoassay for simultaneous detection of CEA and AFP.


The Analyst ◽  
2012 ◽  
Vol 137 (2) ◽  
pp. 393-399 ◽  
Author(s):  
Honglan Qi ◽  
Chen Ling ◽  
Qingyun Ma ◽  
Qiang Gao ◽  
Chengxiao Zhang

Talanta ◽  
2010 ◽  
Vol 81 (1-2) ◽  
pp. 657-663 ◽  
Author(s):  
Hyun Jung Lee ◽  
Sang Hyun Lee ◽  
Tomoyuki Yasukawa ◽  
Javier Ramón-Azcón ◽  
Fumio Mizutani ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document