scholarly journals CURRENT CLINICAL PRACTICE OF THE USE OF TRANSESOPHAGEAL ECHOCARDIOGRAPHY AND CARDIAC COMPUTED TOMOGRAPHY SCAN PRIOR TO PULMONARY VEIN ISOLATION FOR ATRIAL FIBRILLATION IN CANADIAN CENTERS

2014 ◽  
Vol 30 (10) ◽  
pp. S292
Author(s):  
S. Awad ◽  
K. Mohajer ◽  
A. Baranchuk ◽  
R. Pal
2019 ◽  
Vol 8 (1) ◽  
pp. 60-64 ◽  
Author(s):  
Shinsuke Miyazaki ◽  
Hiroshi Tada

Since the cryoballoon (CB) was introduced into clinical practice, more than 400,000 patients have undergone a pulmonary vein (PV) isolation with a CB throughout the world. Although the efficacy of the first-generation CB was limited, the recently introduced secondgeneration CB has achieved a greater uniformity in cooling, which has facilitated a shorter time to PV isolation, shorter procedural times, higher rates of freedom from atrial fibrillation and low rates of PV reconnections. Currently, a single short freeze strategy with a single 28 mm balloon has become the standard technique based on the balance of procedural efficacy and safety. However, enhanced cooling characteristics may also result in a greater potential for collateral damage to non-cardiac structures. Knowledge about the potential complications is essential when performing the procedure. In this article, we describe the important complications that should be noted during a CB procedure, and how to minimise the risk of complications based on our experience.


Author(s):  
Tauseef Akhtar ◽  
Ryan Wallace ◽  
Usama Daimee ◽  
Erica Hart ◽  
Armin Arbab-Zadeh ◽  
...  

Background Transesophageal echocardiography (TEE) is variably performed before atrial fibrillation (AF) ablation to evaluate left atrial appendage (LAA) thrombus. We describe our experience with transitioning to the pre-ablation cardiac computed tomography (CT) approach for the assessment of LAA thrombus during the COVID-19 pandemic. Methods We studied consecutive patients undergoing AF ablation at our center. The study cohort was divided into pre- vs. post-COVID groups. The pre-COVID cohort included ablations performed during 1 year before the COVID-19 pandemic; pre-ablation TEE was used routinely to evaluate LAA thrombus in high-risk patients. Post-COVID cohort included ablations performed during the 1 year after the COVID-19 pandemic; pre-ablation CT was performed in all patients, with TEE performed only in patients with LAA thrombus by CT imaging. The demographics, clinical history, imaging, and ablation characteristics, and peri-procedural cerebrovascular events (CVE) were recorded. Results A total of 637 patients (pre-COVID n=424, post-COVID n=213) were studied. The mean age was 65.6  10.1 years in the total cohort, and the majority were men. There was a significant increase in pre-ablation CT imaging from pre to post-COVID cohort (74.8 vs. 93.9%, p=<0.01), with a significant reduction in TEEs (34.6 vs. 3.7%, p=<0.01). One patient in the post-COVID cohort developed CVE following negative pre-ablation CT. However, the incidence of peri-procedural CVE between both cohorts remained statistically unchanged (0 vs. 0.4%, p=0.33). Conclusion Implementation of pre ablation CT-only imaging strategy with selective use of TEE for LAA thrombus evaluation is not associated with increased CVE risk during the COVID- 19 pandemic.


Sign in / Sign up

Export Citation Format

Share Document