Evaluation of optimal implant alignment in total hip arthroplasty based on postoperative range of motion simulation

2022 ◽  
pp. 105555
Author(s):  
Satoru Harada ◽  
Satoshi Hamai ◽  
Goro Motomura ◽  
Satoshi Ikemura ◽  
Masanori Fujii ◽  
...  
2009 ◽  
Vol 24 (4) ◽  
pp. 646-651 ◽  
Author(s):  
Akinobu Matsushita ◽  
Yasuharu Nakashima ◽  
Seiya Jingushi ◽  
Takuaki Yamamoto ◽  
Akio Kuraoka ◽  
...  

2021 ◽  
pp. 112070002110448
Author(s):  
Ryo Mitsutake ◽  
Hiromasa Tanino ◽  
Hiroshi Ito

Background: Dislocation continues to be a common complication following total hip arthroplasty (THA). Although previous studies of computed simulation analysis investigated the range of motion (ROM), it is unclear whether the ROM before impingement simulated using computed tomography-based 3-dimensional simulation analysis (simulated ROM) is related to dislocation after THA. It is also unclear what angles are required in computed simulation analyses for stable hips after THA. In this study, we compared the simulated ROM in patients with and without dislocation. Methods: 16 patients with posterior dislocation were compared with 48 matched patients without dislocation. Risk factors including preoperative bone morphology of the hip, implant position, change of femoral offset, change of leg length, anterior aspect of the greater trochanter (GTa) length, and anterior inferior iliac spine length were also compared. Results: The mean flexion angle, internal-rotation at 90° flexion (IR) angle, cup anteversion based on the anterior pelvic plane (APP), tilt-adjusted cup anteversion and GTa length were significantly different between patients with dislocation and patients without dislocation ( p = 0.033, 0.002, 0.010, 0.047, 0.046). A receiver-operating characteristic curve analysis suggested cutoff points for flexion angle, IR angle, cup anteversion based on the APP, tilt-adjusted cup anteversion and GTa length, of 114.5°, 45.5°, 19.5°, 12.0° and 15.3 mm. Conclusions: This study suggests that preoperative planning to achieve a larger simulated ROM, flexion angle and IR angle, may reduce the risk of posterior dislocation. This study also suggests that fine-tuning of cup anteversion and/or trimming of the overhanging GTa during preoperative planning may reduce the risk of posterior dislocation.


2013 ◽  
Vol 37 (7) ◽  
pp. 1233-1237 ◽  
Author(s):  
Shinya Hayashi ◽  
Takayuki Nishiyama ◽  
Takaaki Fujishiro ◽  
Shingo Hashimoto ◽  
Noriyuki Kanzaki ◽  
...  

2016 ◽  
Vol 136 (7) ◽  
pp. 1015-1020 ◽  
Author(s):  
Michael Woerner ◽  
Markus Weber ◽  
Ernst Sendtner ◽  
Robert Springorum ◽  
Michael Worlicek ◽  
...  

2017 ◽  
Vol 19 (5) ◽  
pp. 0-0 ◽  
Author(s):  
Anna Świtoń ◽  
Ewa Wodka-Natkaniec ◽  
Łukasz Niedźwiedzki ◽  
Tadeusz Gaździk ◽  
Tadeusz Niedźwiedzki

Background. Coxarthrosis is a chronic musculoskeletal condition that causes severe pain and considerable limi­tation of the patient’s motor performance. Total hip arthroplasty is one of the most common and effective methods used in the treatment of advanced degenerative changes. The aim of the present study was to evaluate the activity and quality of life of patients after unilateral total hip arthroplasty. Material and methods. The study was conducted in a group of 189 patients who had undergone unilateral total hip arthroplasty. Goniometry was used to determine the range of motion of both hip joints. Patients’ physical ability and pain severity were assessed based on the Harris Hip Score (HHS) questionnaire. Results. The examination of the range of motion in the lower extremities revealed statistically significant diffe­rences in flexion (p<0.01), abduction (p=<0.01), adduction (p<0.01) and external rotation (p<0.01) between the operated and the healthy extremity. The greatest limitation of motion was demonstrated for external rotation (<14°). Approximately 14% of the patients were not able to perform this motion in their healthy hip joint, while 17.5% of them could not do so in the affected hip joint. Analysis of HHS results (mean = 79 pts) revealed that more than 50% of the patients described their functional ability and quality of life as good and excellent. It was demonstrated that 54% of patients did not suffer from pain, whereas minor or mild pain was noted in 35%. Conclusions: 1. A subjective clinical assessment of patients after total hip arthroplasty showed that their quality of life had improved. 2. It is necessary to perform physiotherapy after total hip arthroplasty, on both the operated and healthy side. 3. Exacerbation of pain and impaired activity in patients after total hip arthroplasty were associated with the female sex to a considerable extent.


2007 ◽  
Vol 26 (4) ◽  
pp. 443-452 ◽  
Author(s):  
Oliver Kessler ◽  
Shantanu Patil ◽  
Wirth Stefan ◽  
Eckart Mayr ◽  
Clifford W. Colwell ◽  
...  

2014 ◽  
Vol 39 (4) ◽  
pp. 645-651 ◽  
Author(s):  
Masanobu Hirata ◽  
Yasuharu Nakashima ◽  
Daisuke Hara ◽  
Masayuki Kanazawa ◽  
Yusuke Kohno ◽  
...  

2021 ◽  
Author(s):  
Ryo Hidaka ◽  
Kenta Matsuda ◽  
Masaki Nakamura ◽  
Shigeru Nakamura ◽  
Hirotaka Kawano

Abstract Background Obtaining a larger theoretical range of motion (ROM) is crucial to avoid prosthetic impingement after total hip arthroplasty (THA); however, no reports have examined the permissible range values of combined anteversion (CA) satisfying targeted ROM without prosthetic impingement. This retrospective study aimed to evaluate the possible postoperative CA extent that would allow meeting target ROM criteria according to Yoshimine’s theory using computed tomography (CT)-based three-dimensional motion analysis after THA. Methods This study included 114 patients (133 hips) who underwent cementless primary THA using a CT-based navigation system and implants (oscillation angle ≥ 135°). Implant positions were determined using Yoshimine's CA formula. Postoperative evaluation was conducted using a three-dimensional templating software for CT data. The postoperative Yoshimine’s and Widmer’s CA was calculated, and the difference between the target and postoperative values was defined as the error of Yoshimine’s CA and Widmer’s CA. Prosthetic ROM was assessed by Yoshimine’s stringent criteria for activities of daily living. Based on fulfilling these criteria, all patients were divided into the ROM (+) and ROM (-) groups. Evaluation items were compared between the two groups. Results There were 111 and 22 hips in the ROM (+) and ROM (-) groups, respectively. A significant difference was noted in the absolute error of Yoshimine’s and Widmer’s CA between the two groups. Using receiver operating characteristic analysis, threshold values of 6.0 (higher values indicate greater disability; sensitivity 90.9%, specificity 72.1%) for the absolute Yoshimine’s CA difference (area under the curve [AUC] 0.87, P < 0.01) and 6.9 (higher values indicate greater disability; sensitivity 68.2%, specificity 88.3%) for the absolute Widmer’s CA difference (AUC 0.83, P < 0.01) were predictors in the ROM (-) group. Conclusions The target range of Yoshimine’s CA (90.8°±6.0°) and Widmer’s CA values (37.3°±6.9°) was crucial in implant orientation for obtaining theoretical ROM without prosthetic impingement after THA.


Sign in / Sign up

Export Citation Format

Share Document