An interactive interface for seizure focus localization using SPECT image analysis

2006 ◽  
Vol 36 (1) ◽  
pp. 70-88 ◽  
Author(s):  
Mark Rossman ◽  
Malek Adjouadi ◽  
Melvin Ayala ◽  
Ilker Yaylali
2017 ◽  
Vol 28 (3) ◽  
pp. 77
Author(s):  
Moo-Sub Kim ◽  
Han-Back Shin ◽  
Sunmi Kim ◽  
Jae Goo Shim ◽  
Do-Kun Yoon ◽  
...  
Keyword(s):  

Epilepsia ◽  
2007 ◽  
Vol 48 (7) ◽  
pp. 1409-1413 ◽  
Author(s):  
Michael Feichtinger ◽  
Hans Eder ◽  
Alexander Holl ◽  
Eva Körner ◽  
Gerda Zmugg ◽  
...  

2001 ◽  
Vol 1 (1) ◽  
Author(s):  
Tetsuro Naruo ◽  
Yoshiaki Nakabeppu ◽  
Daisuke Deguchi ◽  
Nobuatsu Nagai ◽  
Junko Tsutsui ◽  
...  

1989 ◽  
Vol 2 (3) ◽  
pp. 129-135 ◽  
Author(s):  
Thomas Jay Rosenbaum ◽  
Kenneth D. Laxer

2000 ◽  
Vol 75 (6) ◽  
pp. 615-624 ◽  
Author(s):  
Benjamin H. Brinkmann ◽  
Terence J. O'Brien ◽  
Brian P. Mullan ◽  
Michael K. O'Connor ◽  
Richard A. Robb ◽  
...  

Neurosurgery ◽  
1986 ◽  
Vol 19 (1) ◽  
pp. 73-81 ◽  
Author(s):  
Thomas J. Rosenbaum ◽  
Kenneth D. Laxer ◽  
Michael Vessely ◽  
W. Brewster Smith

Abstract Fifty patients with medically refractory partial seizure disorders have undergone subdural electrode placement for seizure focus localization. Standard scalp telemetry recordings of ictal events had failed to demonstrate accurately the site of seizure onset, and these patients were considered candidates for telemetry with intracerebral depth electrodes. Excellent recordings of interictal and ictal events were obtained, and localization of the epileptogenic focus was derived from recordings made during spontaneously occurring seizures. Electrocorticograms were monitored for up to 21 days. The recordings enabled a surgical decision to be made in 43 of 50 cases (86%). Thirty patients have subsequently undergone cortical excision of their foci with good results. Subdural electrode recordings are a significant addition to the armamentarium of the neurosurgeon attempting to localize surgical seizure foci, offering a low morbidity procedure as an alternative to depth electrode implantation.


2011 ◽  
Vol 95 (1-2) ◽  
pp. 35-50 ◽  
Author(s):  
Kourosh Jafari-Khouzani ◽  
Kost Elisevich ◽  
Kastytis C. Karvelis ◽  
Hamid Soltanian-Zadeh

Neurosurgery ◽  
1986 ◽  
Vol 19 (1) ◽  
pp. 73???81 ◽  
Author(s):  
T J Rosenbaum ◽  
K D Laxer ◽  
M Vessely ◽  
W B Smith

2007 ◽  
Vol 22 (2) ◽  
pp. 1-3 ◽  
Author(s):  
Medina C. Kushen ◽  
David Frim

✓Subdural electrode arrays are placed to localize seizure foci for possible resection. The procedure is usually straightforward when an electrode grid array is placed on the brain convexity but can become complicated if the surface on which the grids are applied is not convex. Arachnoid cysts can be associated with seizures, but their topography presents a challenge to standard techniques for the placement of subdural grids. The authors report on a technique for electrode grid placement that successfully localized seizure foci in the depths of arachnoid cysts in two patients. Subdural grids were placed to conform to the concave cyst cavity. They were held in place with rolled gelatin foam padding, which filled the arachnoid cyst. The padding was removed before removing the electrode grids and resecting the seizure focus. Although arachnoid cysts present a technical challenge when seizure foci are located within the cyst cavity, the technique of packing the cyst cavity with gelatin foam provides good electrode contact on the concave cyst wall, allowing adequate seizure focus localization.


Sign in / Sign up

Export Citation Format

Share Document