Structural performance of RC beams containing high-volume ground granulated blast furnace slag and recycled coarse aggregate with lime

2021 ◽  
Vol 307 ◽  
pp. 124907
Author(s):  
Rajib K. Majhi ◽  
Amar N. Nayak ◽  
Rama B. Swain
Materials ◽  
2020 ◽  
Vol 13 (4) ◽  
pp. 843
Author(s):  
Yuji Miyazaki ◽  
Takeshi Watanabe ◽  
Yuji Yamada ◽  
Chikanori Hashimoto

Since high quality natural aggregates are becoming scarce, it is important that industrial recycled products and by-products are used as aggregates for concrete. In Japan, the use of recycled aggregate (RG) is encouraged. Since, strength and durability of recycled aggregate concrete is lower than that of normal aggregate concrete, the use of recycled aggregate has not been significant. In order to improve physical properties of concrete using recycled coarse aggregate, blast furnace slag sand has been proposed. Recently, blast furnace slag sand is expected to improve durability, freezing, and thawing damage of concrete in Japan. Properties of fresh and hardened concrete bleeding, compressive strength, and resistance to freezing and thawing which are caused by the rapid freezing and thawing test using liquid nitrogen is a high loader than the JIS A 1148 A method that were investigated. As a result, concrete using treated low-class recycled coarse aggregate and 50% or 30% replacement of crushed sand with blast furnace slag sand showed the best results, in terms of bleeding, resistance to freezing and thawing.


Materials ◽  
2021 ◽  
Vol 14 (23) ◽  
pp. 7159
Author(s):  
Yong-Jun Lee ◽  
Hyeong-Gook Kim ◽  
Kil-Hee Kim

This study was conducted to investigate the effect of ground granulated blast furnace slag on the structural performance of precast concrete beams, evaluating the flexural, shear and bonding performance by using the replacement ratio of the ground granulated blast furnace slag as a variable. The design strength of the concrete was set at 45 MPa in consideration of the characteristics of precast concrete products, and the replacement ratio of the ground granulated blast furnace slag to replace cement was 30 to 70%. The experimental results showed that all specimens had similar behavioral characteristics regardless of the replacement ratio of the ground granulated blast furnace slag. Comparison of the prediction results obtained by ACI 318-19 and EC 2 showed that the mean flexural strength and shear strength were higher than 1.19 and 1.43, respectively, and the mean bond strength was 1.57, satisfying the required performance. Therefore, the experimental results showed that in using the ground granulated blast furnace slag as an admixture for precast concrete, the cement replacement ratio may be increased up to 70% without causing any problems in securing the structural performance. Summarizing the results of the present study, a ground granulated blast furnace slag replacement ratio of 50% or lower may be reasonably applied.


Sign in / Sign up

Export Citation Format

Share Document