scholarly journals A Septin Double Ring Controls the Spatiotemporal Organization of the ESCRT Machinery in Cytokinetic Abscission

2019 ◽  
Vol 29 (13) ◽  
pp. 2174-2182.e7 ◽  
Author(s):  
Eva P. Karasmanis ◽  
Daniel Hwang ◽  
Konstantinos Nakos ◽  
Jonathan R. Bowen ◽  
Dimitrios Angelis ◽  
...  
2018 ◽  
Author(s):  
Eva P. Karasmanis ◽  
Daniel Hwang ◽  
Konstantinos Nakos ◽  
Jonathan R. Bowen ◽  
Dimitrios Angelis ◽  
...  

Author(s):  
Birgit Meindl ◽  
Katharina Pfennigbauer ◽  
Berthold Stöger ◽  
Martin Heeney ◽  
Florian Glöcklhofer

Anthracene derivatives have been used for a wide range of applications and many different synthetic methods for their preparation have been developed. However, despite continued synthetic efforts, introducing substituents in some positions has remained difficult. Here we present a method for the synthesis of 2,3,6,7-substituted anthracene derivatives, one of the most challenging anthracene substitution patterns to obtain. The method is exemplified by the preparation of 2,3,6,7-anthracenetetracarbonitrile and employs a newly developed, stable protected 1,2,4,5-benzenetetracarbaldehyde as the precursor. The precursor can be obtained in two scalable synthetic steps from 2,5-dibromoterephthalaldehyde and is converted into the anthracene derivative by a double intermolecular Wittig reaction under very mild conditions followed by a deprotection and intramolecular double ring-closing condensation reaction. Further modification of the precursor is expected to enable the introduction of additional substituents in other positions and may even enable the synthesis of fully substituted anthracene derivatives by the presented approach.<br>


Radiocarbon ◽  
1967 ◽  
Vol 9 ◽  
pp. 257-260
Author(s):  
H. Willkomm ◽  
H. Erlenkeuser

Most of the measurements reported here have been obtained with the 4.5-L CO2 counter previously described (Kiel I; Erlenkeuser, 1965). A few samples have been dated with a 3-L proportional counter. The copper counter is surrounded by 28 GM counters in the form of a double ring. The total assembly is shielded by 10 cm of old lead. Neither an inner lead shield between counter and anticoincidence ring nor screening of sensitive volume by a quartz tube-as in the 4.5-L counter-has been used. Background of the small counter is 17.20 cpm or The 0.95 x NBS value is 9.5 cpm at 400 torr. Within statistical error background does not depend on atmospheric pressure. The 3-L counter is placed under a concrete wall, 2.5 m in length and 9.4 m in height.


Sign in / Sign up

Export Citation Format

Share Document