proportional counter
Recently Published Documents


TOTAL DOCUMENTS

1167
(FIVE YEARS 46)

H-INDEX

40
(FIVE YEARS 3)

2021 ◽  
Vol 19 (11) ◽  
pp. 22-31
Author(s):  
Sawsan Sh. Fleifil ◽  
Zahraa A. Ismail AL-Sudani

In this study, assessment of levels natural radioactivity in drinking water samples of Misan Province of Iraq was carried out. A total of 33 (Tigris river, station and Tap) water samples collected from eleven places in Misan Province of Iraq. The beta and alpha gross radioactivity of the samples water was measured and an average annual effective dose derived of drinking-water ingestion was estimation utilizing new model a LB-4110 low background gas flow proportional counter. The data indicated that the Beta and Alpha gross activities and annual effective dose in samples did not exceed WHO recommended levels (0.5 Bq/L of Alpha gross, 1.0 Bq/L of Beta gross and 0.1 mSv/y for annual effective dose).


Radiocarbon ◽  
2021 ◽  
pp. 1-7
Author(s):  
Michel Fontugne ◽  
Christine Hatté ◽  
Michel Jaudon

ABSTRACT In 1991, a 14C ß-counting installation with four proportional CO2 gas counters was tested at the Modane underground laboratory, 1700 m below the summit of Pointe du Fréjus, reducing the muon flux to 4 muons per square meter and per day. With cosmic radiation attenuated by a factor of 2.106, the background level of the counters was reduced by 65 to 85% while its variability was reduced by a factor of 30–80 depending on the type of counter. The dating limit of these counters extends to well beyond 60,000 years.


Author(s):  
S. Pommé ◽  
T. Altzitzoglou ◽  
R. Van Ammel ◽  
G. Sibbens

AbstractThe JRC applied six measurement techniques to standardise the activity of an 241Am solution in the frame of the 2003 key comparison CCRI(II)-K2.Am-241. The methods used were alpha-particle counting at a defined small solid angle, high-efficiency particle and photon counting with a windowless 4π CsI(Tl) sandwich spectrometer, 4π alpha counting with a pressurised proportional counter, alpha-gamma coincidence counting and sum counting with a small pressurised proportional counter and a NaI(Tl) well detector, and 4π counting with a liquid scintillation counter. All results were consistent and an unusually low measurement uncertainty of 0.054% was achieved. An overview is presented of the outcome of the key comparison exercise, which demonstrates international equivalence.


2021 ◽  
Vol 42 (2) ◽  
Author(s):  
H. M. Antia ◽  
P. C. Agrawal ◽  
Dhiraj Dedhia ◽  
Tilak Katoch ◽  
R. K. Manchanda ◽  
...  

Author(s):  
Mohamed Fares ◽  
Adnane Messai ◽  
Samir Begaa ◽  
Maameri Salem ◽  
Kassida Negara ◽  
...  

AIP Advances ◽  
2021 ◽  
Vol 11 (3) ◽  
pp. 035118
Author(s):  
Min Zhu ◽  
Biao Li ◽  
Fei Wu ◽  
Shengao Wang ◽  
Shaohua Sun ◽  
...  

2021 ◽  
Vol 8 ◽  
Author(s):  
M. Missiaggia ◽  
E. Pierobon ◽  
M. Castelluzzo ◽  
A. Perinelli ◽  
F. Cordoni ◽  
...  

In microdosimetry, lineal energies y are calculated from energy depositions ϵ inside the microdosimeter divided by the mean chord length, whose value is based on geometrical assumptions on both the detector and the radiation field. This work presents an innovative two-stages hybrid detector (HDM: hybrid detector for microdosimetry) composed by a tissue equivalent proportional counter and a silicon tracker made of 4 low gain avalanche diode. This design provides a direct measurement of energy deposition in tissue as well as particles tracking with a submillimeter lateral spatial resolution. The data collected by the detector allow to obtain the real track length traversed by each particle in the tissue equivalent proportional counter and thus estimates microdosimetry spectra without the mean chord length approximation. Using Geant4 toolkit, we investigated HDM performances in terms of detection and tracking efficiencies when placed in water and exposed to protons and carbon ions in the therapeutic energy range. The results indicate that the mean chord length approximation underestimate particles with short track, which often are characterized by a high energy deposition and thus can be biologically relevant. Tracking efficiency depends on the low gain avalanche diode configurations: 34 strips sensors have a higher detection efficiency but lower spatial resolution than 71 strips sensors. Further studies will be performed both with Geant4 and experimentally to optimize the detector design on the bases of the radiation field of interest.The main purpose of HDM is to improve the assessment of the radiation biological effectiveness via microdosimetric measurements, exploiting a new definition of the lineal energy (yT), defined as the energy deposition ϵ inside the microdosimeter divided by the real track length of the particle.


Sign in / Sign up

Export Citation Format

Share Document