Effect of implant abutment connection designs, and implant diameters on screw loosening before and after cyclic loading: In-vitro study

2019 ◽  
Vol 35 (11) ◽  
pp. e265-e271 ◽  
Author(s):  
Sara Reda Sammour ◽  
Mohamed Maamoun El-Sheikh ◽  
Attiah Aly El-Gendy
2015 ◽  
Vol 25 (3) ◽  
pp. 216-223 ◽  
Author(s):  
Helios A. Zeno ◽  
Renan L. Buitrago ◽  
Sidney S. Sternberger ◽  
Marisa E. Patt ◽  
Nick Tovar ◽  
...  

2020 ◽  
Vol 11 (3) ◽  
pp. 229
Author(s):  
Hariharan Ramakrishnan ◽  
Maniamuthu Ragupathi ◽  
Vallabh Mahadevan ◽  
NS Azhagarasan ◽  
S Jayakrishnakumar

2015 ◽  
Vol 13 (3) ◽  
pp. 0-0 ◽  
Author(s):  
Antonio Scarano ◽  
Vittoria Perrotti ◽  
Adriano Piattelli ◽  
Flavia Iaculli ◽  
Giovanna Iezzi

Author(s):  
Yonggang Liu ◽  
Shanshan Gao ◽  
Yongsheng Han ◽  
Qixiang Yang ◽  
Dwayne Arola ◽  
...  

2017 ◽  
Vol 32 (4) ◽  
pp. 822-829 ◽  
Author(s):  
Sergio Gehrke ◽  
Rafael Delgado-Ruiz ◽  
Juan Frutos ◽  
María Prados-Privado ◽  
Berenice Dedavid ◽  
...  

Materials ◽  
2021 ◽  
Vol 14 (2) ◽  
pp. 385
Author(s):  
Igor Smojver ◽  
Marko Vuletić ◽  
Dražena Gerbl ◽  
Ana Budimir ◽  
Mato Sušić ◽  
...  

The microenvironment of the oral cavity is altered when an implant, a biocompatible foreign body, is inserted into the mouth. Bacteria settle in the tissues in and around the implant due to the passage of microorganisms through the microgap at the connection of the implant and prosthetic abutment. To prevent colonization of the implant by microorganisms, one idea is to use sealing and antimicrobial materials to decontaminate the implant–abutment interface and close the microgap. The purpose of this study is to evaluate the antimicrobial efficacy and permeability of different types of sealing materials at the implant–abutment interface, under static conditions. Three different sealing material (GapSeal gel, Oxysafe gel and Flow.sil) were used for sealing the implant–abutment interfaces in 60 titanium dental implants, which were first contaminated with a solution containing Staphylococcus aureus and Candida albicans for 14 days under an aerobic condition. Results showed that a complete seal against bacterial infection was not formed at the implant–abutment interface, while for fungal infections, only GapSeal material helped to prevent microleakage. Findings of this in vitro study reported that application of sealing material before abutment connection may reduce peri-implant bacterial and fungal population compared with the interface without sealing material.


Sign in / Sign up

Export Citation Format

Share Document