scholarly journals BuildingSync: A schema for commercial building energy audit data exchange

Author(s):  
Nicholas Long ◽  
Katherine Fleming ◽  
Chris CaraDonna ◽  
Cory Mosiman
2003 ◽  
Vol 125 (3) ◽  
pp. 251-257 ◽  
Author(s):  
Jongho Yoon ◽  
E. J. Lee ◽  
D. E. Claridge

Calibration of an energy simulation with actual data has generally been considered too difficult to be part of the energy audit procedure. The purpose of this paper is to develop a systematic method using a “base load analysis approach” to calibrate a building energy performance model with a combination of monthly utility billing data and sub-metered data such as is commonly available in large buildings in Korea. The calibration procedure was specifically developed to be suitable for use in both the audit and savings determination procedure within a retrofit process. The procedure has been visualized using a logical flow chart and demonstrated using the simulation of a 26-story commercial building located in Seoul as a case study. The results indicate that the approach developed provided a reliable and accurate simulation of the monthly and annual building energy requirements of the case study building.


2018 ◽  
Vol 150 ◽  
pp. 06040
Author(s):  
M. H. Amlus ◽  
Amlus Ibrahim ◽  
Ahmad Zaidi Abdullah ◽  
Nurhafiza Azizan ◽  
Ummi Naeimah Saraeh

Lately Malaysia energy consumption versus generation rapidly shows increasing due to increasing of load. This phenomenon happened following to advanced country development. Lacking on design and without energy management approach the energy consumption and monthly electrical bill will steadily increased and support the increasing of world carbon emission. Therefore the aim of this work is to approach the simplest innovation task-energy audit , which is load-apportioning strategy. This approach using matching the usage of equipment with fully utilized space and reschedules the time of usage. A one week data was collected by logged power meter at main switchboard at selected building using Fluke Power Recorder. From the data collected, current usage of every load can be determine, then load will be arrange into a group with same portion and same time of usage. The result shows clearly the energy consumption for every single day and indicates the highest and lowest peak. From this work the apportioning strategy implemented by rearrange the load following type of room application. After the arrangement, new measurement was taken and a very good result was established. This work also can be further apply for a huge load that can be save a lot of money for owner especially government by energy saving.


2015 ◽  
Vol 5 (2) ◽  
pp. 29-36 ◽  
Author(s):  
I. Giurca

Abstract The article presents aspects related to the calculation of heat loss through the pipes of the interior central heating system. The purpose of the article is to detail the local heat losses in case of central heating systems. Based on the conclusions of the article, we propose the modification of the calculation methodology related to the building energy audit.


Sign in / Sign up

Export Citation Format

Share Document