scholarly journals Single-Stage Anterior Cruciate Ligament Revision Reconstruction Using an Allograft Bone Dowel for a Malpositioned and Widened Femoral Tunnel

Author(s):  
Justin J. Ernat ◽  
Dylan R. Rakowski ◽  
Peter J. Millett
2016 ◽  
Vol 24 (3) ◽  
pp. 286-288
Author(s):  
Ravi Gupta ◽  
Anubhav Malhotra ◽  
Pawan Kumar ◽  
Gladson David Masih

Purpose To measure the femoral tunnel length created through a far medial portal and determine its correlation with body height, limb length, and thigh length in 404 Indian patients undergoing anterior cruciate ligament (ACL) reconstruction. Methods 364 male and 40 female Indian patients aged 18 to 51 (mean, 26.8) years underwent ACL reconstruction by a single surgeon using the hamstrings tendon autograft. Their body height, limb length, and thigh length were measured by a single assessor, as was the femoral tunnel length. Results The mean femoral tunnel length was 34.5 mm. It was <30 mm in 28 patients and <25 mm in 2 patients. The correlation coefficients of the femoral tunnel length with body height, limb length, and thigh length were 0.485 (p<0.0001), 0.426 (p<0.0001), and 0.304 (p<0.0001). No patient had posterior wall blowout fracture. Conclusion The femoral tunnel length positively correlated with body height, limb length, and thigh length in 404 Indian patients.


2014 ◽  
Vol 2 (11_suppl3) ◽  
pp. 2325967114S0027
Author(s):  
Osman Çiloğlu ◽  
Hakan Çiçek ◽  
Ahmet Yılmaz ◽  
Metin Özalay ◽  
Gökhan Söker ◽  
...  

Objectives: We investigated the effects anatomic or nonanatomic femoral tunnel positions and tunnel fixation methods obtained using two different surgery methods on tunnel widening and clinical results in anterior cruciate ligament (ACL) reconstructions. Methods: Patients with isolated anterior cruciate ligament rupture are included to study who don’t have intra-and extra-articular additional pathology of the knee, without previously a history of operations of both knees. 2 groups were created. Group 1 Aperfix implant were used which can be able to perform non anatomical femoral tunnel and intra tunnel fixation with transtibial technique. In Group 2 Endobutton CL implant were used which can make fixation from outside the cortex with anatomic femoral tunnel in use of anteromedial portal techniques. 27 patients (average age 29,33, range 18 to 55 years) in group 1 and 27 patients (average age 27,51, range 16 to 45 years) in group 2 totally 54 patients were performed surgery. All patients were assessed using the IKDC (International knee documentation committee), Tegner Activity Scala and Lysholm II Functional Scores. Muscle strength measurements in both groups compared to intact knee was measured with an isokinetic dynamometer Biodex System 3 Pro. The location of the femoral tunnel aperture and tunnel widening were imaged with 3D reconstructive computed tomography. All measurements were performed using the same software application by the same radiologist. Results: The two groups were similar with respect to age and sex distribution, operated side, the size of the tunnel created, and follow-up period (p>0.05). After surgery in both groups, the clinical scores showed significant improvement compared to preoperative (p=0,0001). However, postoperative clinical outcomes in the two groups did not show a difference significantly (p>0,005). Isokinetic muscle strength study showed significant differences between the two groups (p=0,0001). Location of femoral tunnel aperture on the medial wall of the lateral femoral condyle showed a significant differences in the two groups (p=0,0001). The expansion of proximal and distal femoral tunnel in two groups showed significant differences (p=0,0001). There was relationship between distal femoral tunnel widening and location of femoral tunnel aperture. Conclusion: Although there is no statistically significant difference between the two groups clinically, difference noticed in terms of isokinetic muscle strength may be due to differences in the degree of shift as a result of multiple loading depending on the biomechanical properties of materials. We thought that the difference seen in the widening of tunnel in the proximal or distal may be due to, the technique of graft fixation, the distance between the fixation point and the joint, and to the location of the femoral tunnel aperture on medial wall of lateral condyle from anatomical or non anatomical region. There is no golden standard in neither surgical technique nor material of fixation. Proper theoretical knowledge and extensive clinical experience are important in the light of an accurate surgical technique applied. We thought that information we have reached in our study should be supported by biomechanical studies


2021 ◽  
Author(s):  
Lifeng Yin ◽  
Hua Zhang ◽  
Junbo Liu ◽  
xingyu zhang ◽  
zhengxing wen ◽  
...  

Abstract Background: Cortical suspensory femoral fixation is commonly performed for graft fixation of the femur in anterior cruciate ligament (ACL) reconstruction using hamstring tendons. This study aimed to compare the morphology of femoral tunnel and graft insertion between fixed-length loop devices (FLD) and adjustable-length loop devices (ALD) using computed tomography (CT) images on the first day after hamstring ACL reconstruction. Methods: Overall, 94 patients who underwent ACL reconstruction from January 2016 to January 2021 were included. For femoral graft fixation, FLD (Smith & Nephew, ENDOBUTTON) and ALD (DePuy Synthes, Mitek sports medicine, RIGIDLOOP Adjustable cortical system) were used in 56 and 38 patients, respectively (FLD and ALD groups). For evaluation of the morphology of the humeral tunnel and graft depth, CT scans were performed immediately on the first postoperative day. The gap distance between the top of the graft and the socket tunnel end, the length of lateral bone preservation, and the depth of graft insertion were measured on the CT images. Results: The gap distance and bone preservation significantly differed between the two groups (1.90±1.81 mm and 14.35±4.67 mm in ALD groups; 7.08±2.63 mm and 7.35±3.62 mm in FLD groups, respectively; both P values < 0.01). The graft insertion depth did not significantly differ between the groups. Conclusion: The ALD group had a smaller gap distance, better bone preservation, and a similar graft insertion length in the femoral tunnel when compared to the FLD group. Based on these findings, ALD might be better for bone preservation and tunnel utilization in patients with short femoral tunnels. Trial registration: retrospectively registered


2021 ◽  
Vol 0 ◽  
pp. 1-4
Author(s):  
Raju Easwaran

This paper describes a simple, reproducible technique of placing the femoral guide wire perfectly in primary/ revision anterior cruciate ligament reconstruction using a bull’s eye outside-in jig. Technique pearls and pitfalls are also mentioned.


Sign in / Sign up

Export Citation Format

Share Document