scholarly journals Impact of Solar Photovoltaic System on Transformer Tap Changer in Low Voltage Distribution Networks

2016 ◽  
Vol 103 ◽  
pp. 58-63 ◽  
Author(s):  
Cheiw Yun Lau ◽  
Chin Kim Gan ◽  
Zainal Salam ◽  
Mohamad Fani Sulaima
Energies ◽  
2020 ◽  
Vol 13 (18) ◽  
pp. 4887
Author(s):  
Meysam Shamshiri ◽  
Chin Kim Gan ◽  
Junainah Sardi ◽  
Mau Teng Au ◽  
Wei Hown Tee

The recent proliferation of residential solar photovoltaic systems has prompted several technical challenges to the operation of low voltage (LV) distribution networks. More specifically, the mismatch of the solar generation and demand profiles, particularly during the midday when the demand is low and solar generation is high, can lead to network overvoltages and increased network losses. In addition, the solar photovoltaic system is not able to reduce the system’s maximum demand, given the residential LV network would normally have an evening peak when the sun goes down. In this regard, this paper examines two different control strategies in designing the battery energy storage system. One aims to eliminate reverse flow caused by the surplus solar energy and the other aims for peak demand reduction.


Author(s):  
Thomas Degner ◽  
Thorsten Reimann ◽  
Gunter Arnold ◽  
Philipp Strauß ◽  
Michael Breede ◽  
...  

2021 ◽  
Vol 3 (1) ◽  
Author(s):  
Varaprasad Janamala

AbstractA new meta-heuristic Pathfinder Algorithm (PFA) is adopted in this paper for optimal allocation and simultaneous integration of a solar photovoltaic system among multi-laterals, called interline-photovoltaic (I-PV) system. At first, the performance of PFA is evaluated by solving the optimal allocation of distribution generation problem in IEEE 33- and 69-bus systems for loss minimization. The obtained results show that the performance of proposed PFA is superior to PSO, TLBO, CSA, and GOA and other approaches cited in literature. The comparison of different performance measures of 50 independent trail runs predominantly shows the effectiveness of PFA and its efficiency for global optima. Subsequently, PFA is implemented for determining the optimal I-PV configuration considering the resilience without compromising the various operational and radiality constraints. Different case studies are simulated and the impact of the I-PV system is analyzed in terms of voltage profile and voltage stability. The proposed optimal I-PV configuration resulted in loss reduction of 77.87% and 98.33% in IEEE 33- and 69-bus systems, respectively. Further, the reduced average voltage deviation index and increased voltage stability index result in an improved voltage profile and enhanced voltage stability margin in radial distribution systems and its suitability for practical applications.


Sign in / Sign up

Export Citation Format

Share Document