scholarly journals First Egyptian experience of Transcatheter Aortic Valve Implantation: Immediate results and one year follow up

2014 ◽  
Vol 66 (1) ◽  
pp. 17-21 ◽  
Author(s):  
Ahmed A. Khashaba ◽  
Walaa Adel ◽  
Alaa Roshdi ◽  
Ahmed Gafar ◽  
Sherif Essam ◽  
...  
2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
T J Cahill ◽  
J Raby ◽  
P D Jewell ◽  
P F Brennan ◽  
A P Banning ◽  
...  

Abstract Introduction Infective endocarditis (IE) is a potentially fatal complication of prosthetic valve replacement and increasing use of transcatheter aortic valve implantation (TAVI) has resulted in a new elderly and frail population at increased risk of IE. The incidence of IE after TAVI and factors that influence the risk and subsequent outcome are relatively unknown. Purpose To describe the incidence, predictors, echocardiographic findings, microbiology and clinical outcomes of IE following TAVI in the United Kingdom (UK). Methods Patients who underwent TAVI between Jan 1 2007 and Dec 31 2016 were identified from the UK TAVI database held by the National Institute for Cardiovascular Outcomes Research. For this cohort, all hospital admissions with a primary diagnosis of IE were identified by linkage with the NHS Hospital Episode Statistics Admitted Patient Care database, or by contact with regional TAVI centres. Additional information concerning clinical presentation, imaging findings, microbiology, management and patient outcome were obtained where possible from the treating physician. Results A total of 16,014 patients underwent TAVI, of whom 157 developed IE over a median follow-up of 23.8 (IQR 7.8–52.4) months - an overall incidence of 0.98% (0.53% at one year post-TAVI). The mean age of patients with IE was 79.2±7.8 years, and 69% were male. The median time to IE following TAVI was 10.0 (IQR 4.0–22.3) months. On multivariate analysis, IE was significantly more common in men (HR 2.05, 95% CI 1.35–3.11, p=0.001) and in patients receiving mechanically-expandable (HR 2.15, 95% CI 1.16–4.01, p=0.015) or balloon-expandable valves (HR 1.60, 95% CI 1.01–2.52, p=0.045) compared to self-expanding valves. IE was also more common in those with an aortic valve peak gradient following TAVI deployment greater than median (HR 1.81, 95% CI 1.23–2.67, p=0.003). The most common presenting symptom was fever (present in 67.1%). The most frequent causal organisms were enterococci (25.9%), followed by oral streptococci (16.4%) and Staphylococcus aureus (11.8%). Transoesophageal echocardiography demonstrated vegetations in 72.5% of patients, most commonly on the TAVI valve leaflets (58.8%). Only 8.24% of patients underwent surgical valve intervention. Survival rates at hospital discharge and one year follow up were 61.4% and 54.4%, respectively. Specific factors associated with one-year mortality were cardiogenic shock (HR 4.6, 95% CI 2.1–10.3, p=0.0002), septic shock (HR 3.4, 95% CI 1.4–8.3, p=0.006) and stroke (HR 4.9, 95% CI 1.46–16.7, p=0.01). Conclusions The incidence of IE one year after TAVI was 0.53% and greater risk was associated with male sex, mechanically-expandable and balloon-expandable valves, and elevated post-deployment valve gradient. Enterococci were the most common causative organism. Overall survival at one year was 54.4%, with adverse outcome predicted by cardiogenic shock, septic shock or stroke.


2015 ◽  
Vol 63 (06) ◽  
pp. 493-500 ◽  
Author(s):  
Luca Koechlin ◽  
Beat Kaufmann ◽  
Arnheid Kessel-Schaefer ◽  
Brigitta Gahl ◽  
Friedrich Eckstein ◽  
...  

2015 ◽  
Vol 16 (4) ◽  
pp. 296-302 ◽  
Author(s):  
Stefano Salizzoni ◽  
Matteo Anselmino ◽  
Cristina Fornengo ◽  
Francesca Giordana ◽  
Michele La Torre ◽  
...  

2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
M Karmpalioti ◽  
G Benetos ◽  
M Drakopoulou ◽  
M Xanthopoulou ◽  
K Stathogiannis ◽  
...  

Abstract Introduction Transcatheter aortic valve implantation (TAVI) has become the standard of care for high-risk and inoperable surgical patients and a valid alternative in intermediate-risk patients with severe aortic stenosis.The DIRECT trial (Predilatation in Transcatheter Aortic Valve Implantation Trial) was a multicenter, randomized, clinical trial designed to evaluate the safety and efficacy of TAVI with or without balloon aortic valvuloplasty (BAV) in patients with symptomatic, severe aortic valve stenosis. Purpose To compare the one year echocardiographic findings among patients, who underwent TAVI using a self-expanding valve with or without BAV. Methods A total of 171 patients with severe aortic stenosis were randomly assigned at 4 tertiary centers to undergo TAVI with the use of self-expanding prostheses with (pre-BAV) or without pre-dilatation (no-BAV). Follow up transthoracic echocardiography was performed 1 year after TAVI. Results Of 171 patients, 86 patients were randomized to pre-BAV group and 85 to no-BAV group. One year echocardiographic follow up was available in 146 patients. In one year follow up there was no significant difference between pre-BAV and no-BAV group in aortic valve area (1.84±0.39cm2 vs. 1.85±0.44cm2, p=0.79), peak aortic valve gradient (15.95±9.97 mmHg vs. 14.51±6.60 mmHg, p=0.35), mean aortic valve gradient (8.37±5.01 mmHg vs. 7.99±4.04 mmHg, p=0.64), aortic valve peak velocity (1.90±0.51 m/s vs. 1.80±0.42m/s, p=0.24), ejection fraction (54.19±8.36% vs. 53.19±9.58%, p=0.52) and pulmonary artery systolic pressure (41.86±14.34 mmHg vs. 40.71±12.40 mmHg, p=0.64). The incidence of moderate or severe paravalvular regurgitation (PVL) in 1 year follow up was 6.2% without significant difference between the 2 study groups (5.7% in the no-BAV group vs. 6.6% in the pre-BAV group, p=0.83). Conclusions Direct transcatheter aortic valve implantation has no impact on one-year prosthesis function and PVL in patients undergoing TAVI with self-expanding valve Funding Acknowledgement Type of funding source: Private company. Main funding source(s): Medtronic


Circulation ◽  
2020 ◽  
Vol 142 (Suppl_3) ◽  
Author(s):  
Vasiliki Gardikioti ◽  
Dimitrios Terentes-printzios ◽  
Konstantinos Aznaouridis ◽  
George Latsios ◽  
Gerasimos Siasos ◽  
...  

Introduction: Transcatheter aortic valve implantation (TAVI) is a procedure that alters dramatically the hemodynamics in patients with severe aortic valve stenosis who undergo this procedure. Hypothesis: We investigated the hypothesis that arterial properties and hemodynamics are affected immediately after TAVI as well as in the long-term. Methods: We enrolled 90 patients (mean age 80.2 ± 8.1 years, 50% males) with severe symptomatic aortic stenosis undergoing TAVI. Carotid-femoral and brachial-ankle pulse wave velocity (cfPWV and baPWV) were used for the assessment of arterial stiffness. Augmentation index corrected for heart rate (AIx@75) and subendocardial viability ratio (SEVR) were measured non-invasively. Measurements were conducted at baseline, after the procedure (during hospitalization) and at 1 year. Results: Acutely after TAVI we observed a statistically significant increase in arterial stiffness (7.5 ± 1.5 m/s vs 8.4 ± 1.9 m/s, p=0.001 for cfPWV and 1,773 ± 459 cm/s vs 2,383 ± 645 cm/s, p<0.001 for baPWV) without a concomitant change in systolic blood pressure (Figure). One year later, arterial stiffness was still increased compared to pre-TAVI measurements (7.5 ± 1.5 m/s vs 8.7 ± 1.7 m/s, p<0.001 for cfPWV and 1,773 ± 459 cm/s vs 2,286 ± 575 cm/s, p<0.001 for baPWV). We also found a decrease in AIx@75 (32.2 ± 12.9 % vs 27.9± 8.4 %, p=0.016) after TAVI that was attenuated at 1-year follow-up (32.2 ± 12.9 % vs 29.8± 9.1 %, p=0.38). SEVR displayed an increase acutely after TAVI (131.2 ± 30.0 % vs 148.4± 36.1 %, p=0.002) and remained improved 1 year after the procedure (131.2 ± 30.0 % vs 146± 32.2 %, p=0.01). Conclusions: In conclusion, shortly after TAVI the aorta exhibits a "stiffer" behavior in response to the acute change in hemodynamics, which settles in the long term. Our findings further elucidate the hemodynamic consequences of TAVI and may entail a prognostic role in this growing population.


Sign in / Sign up

Export Citation Format

Share Document