A novel Pb-poly aminophenol glassy carbon electrode for determination of tetracycline by adsorptive differential pulse cathodic stripping voltammetry

2017 ◽  
Vol 227 ◽  
pp. 345-356 ◽  
Author(s):  
Zeinab Rajab Dizavandi ◽  
Alireza Aliakbar ◽  
Mehdi Sheykhan
2019 ◽  
Vol 63 (1) ◽  
Author(s):  
Mehdi Jalali ◽  
Zeinab Deris Falahieh ◽  
Mohammad Alimoradi ◽  
Jalal Albadi ◽  
Ali Niazi

The electrochemical behavior of Bi+3 ions on the surface of a glassy carbon electrode, in acidic media and in the presence of tamoxifen, was investigated. Cyclic voltammetry, chronoamperometry, differential pulse voltammetry, electrochemical impedance spectroscopy, and scanning electron microscopy with energy-dispersive X-ray spectroscopy were used to find the probable mechanism contributing to the reduction of the peak height of bismuth oxidation with an increase in the concentration of tamoxifen. The obtained results show a slight interaction between the bismuth species and tamoxifen which co-deposit on the surface of glassy carbon electrode. Therefore, the reduction in the peak height of bismuth oxidation as a function of tamoxifen concentration was used to develop a new differential pulse anodic striping voltammetry method for determination of trace amount of tamoxifen. The effects of experimental parameters on the in situ DPASV of Bi+3 ions in the presence of tamoxifen shown the optimal conditions as: 2 mol L-1 H2SO4 (1% v v-1 MeOH), a deposition potential of -0.5 V, a deposition time of 60 s, and a glassy carbon electrode rotation rate of 300 rpm. The calibration curve was plotted in the range of 0.5 to 6 µg mL-1 and the limits of detection and quantitation were calculated to be 3.1 × 10-5 µg mL-1 and 1.0 × 10-4 µg mL-1, respectively. The mean, RSD, and relative bias for 0.5 µg mL-1 (n=5) were found to be 0.49 µg mL-1, 0.3%, and 2%, respectively. Finally, the proposed method was successfully used for the determination of tamoxifen in serum and pharmaceutical samples.


Molecules ◽  
2021 ◽  
Vol 26 (10) ◽  
pp. 2958
Author(s):  
Waree Boonmee ◽  
Kritsada Samoson ◽  
Janjira Yodrak ◽  
Adul Thiagchanya ◽  
Apichai Phonchai ◽  
...  

A simple and highly sensitive electrochemical sensor was developed for adsorptive cathodic stripping voltammetry of alprazolam. Based on an electrochemically pretreated glassy carbon electrode, the sensor demonstrated good adsorption and electrochemical reduction of alprazolam. The morphology of the glassy carbon electrode and the electrochemically pretreated glassy carbon electrode were characterized by scanning electron microscopy/energy dispersive X-ray spectroscopy, Fourier transform infrared spectroscopy, cyclic voltammetry, and electrochemical impedance spectroscopy. The electrochemical behaviors of alprazolam were determined by cyclic voltammetry, and the analytical measurements were studied by adsorptive cathodic stripping voltammetry. Optimized operational conditions included the concentration and deposition time of sulfuric acid in the electrochemical pretreatment, preconcentration potential, and preconcentration time. Under optimal conditions, the developed alprazolam sensor displayed a quantification limit of 0.1 mg L−1, a detection limit of 0.03 mg L−1, a sensitivity of 67 µA mg−1 L cm−2 and two linear ranges: 0.1 to 4 and 4 to 20 mg L−1. Sensor selectivity was excellent, and repeatability (%RSD < 4.24%) and recovery (82.0 ± 0.2 to 109.0 ± 0.3%) were good. The results of determining alprazolam in beverages with the developed system were in good agreement with results from the gas chromatography–mass spectrometric method.


2018 ◽  
Vol 10 (24) ◽  
pp. 2917-2923 ◽  
Author(s):  
Zorica Stojanović ◽  
Zuzana Koudelkova ◽  
Eliska Sedlackova ◽  
David Hynek ◽  
Lukas Richtera ◽  
...  

In this work, differential pulse anodic stripping voltammetry (DP-ASV) for the determination of trace amounts of hexavalent chromium (Cr(vi)) at a silver plated glassy carbon electrode (Ag plated-GCE) is described in detail.


Sign in / Sign up

Export Citation Format

Share Document