Retrofit strategies towards Net Zero Energy Educational Buildings: A case study at the University of the Basque Country

2017 ◽  
Vol 144 ◽  
pp. 387-400 ◽  
Author(s):  
O. Irulegi ◽  
A. Ruiz-Pardo ◽  
A. Serra ◽  
J.M. Salmerón ◽  
R. Vega
Author(s):  
Benjamin P. Barnes ◽  
Luis A. Martinez ◽  
Trishan Esram ◽  
Ty A. Newell ◽  
Patrick L. Chapman

This paper describes the mechanical systems, the DC-coupled electrical system, the simulation approach and the preliminary results of the University of Illinois entry in the 2007 Department of Energy Solar Decathlon competition. The competition showcased twenty net-zero energy solar powered houses. The University of Illinois entry was the only one that featured an all-electric design. No solar thermal collectors were used; space and water heating was accomplished primarily through heat pumps. Each of three house modules is sensibly conditioned with autonomous, custom mini-split heat pumps using all radiant and natural convection heat exchange for the interior side. Simulation methods are described and assumptions of wall and window properties, mechanical system performance and electrical system performance are disclosed. Details are provided on the theoretical analysis of internal heat transfer and the basic design of the custom mechanical system. The electrical system topology and equipment choices are presented and initial performance results are shown. Additionally, preliminary analysis is carried out on the data taken during the Solar Decathlon competition and on the observations of post-competition winter performance. The success in being awarded comfort conditioning points during the competition is discussed along with drawbacks not represented in the competition results.


Author(s):  
Caroline Hachem-vermette ◽  
Chinyere Dara ◽  
Rhys Kane

The paper summarizes an investigation of the performance of container based housing units developed by Ladacor Ltd, and compares this performance to traditional housing constructed according to existing standards and codes. The results indicate that the case study housing system can reduce thermal loads (heating and cooling) by about 57% as compared to the same house designed according to the code. Implementing additional efficiency measures and solar design strategies such as increased south window size, suitable shading devices, thermal mass, and more airtight construction, leads to improved performance. This enhanced scenario can reduce the thermal load by 72% as compared to the code scenario and by about 35% as compared to the original case study system. Achieving a net-zero energy status can be reached by integrating photovoltaics on the south roof of the single-family housing designed with Ladacor roof, assuming energy efficient appliances, lighting and domestic hot water. The optimal case can reach a net positive energy status, with a PV system integrated on the south facing roof surface. Results from this investigation can serve in developing innovative design concepts and guidelines for the design of low cost, self-sufficient modular housing.


2017 ◽  
Vol 12 (2) ◽  
pp. 38-55 ◽  
Author(s):  
Ming Hu

1.0. INTRODUCTION In the United States, K–12 school buildings spend more than $8 billion each year on energy—more than they spend on computers and textbooks combined [1]. Most occupied older buildings demonstrate poor operational performance—for instance, more than 30 percent of schools were built before 1960, and 53 percent of public schools need to spend money on repairs, renovations, and modernization to ensure that the schools' onsite buildings are in good overall condition. And among public schools with permanent buildings, the environmental factors in the permanent buildings have been rated as unsatisfactory or very unsatisfactory in 5 to 17 percent of them [2]. Indoor environment quality (IEQ) is one of the core issues addressed in the majority of sustainable building certification and design guidelines. Children spend a significant amount of time indoors in a school environment. And poor IEA can lead to sickness and absenteeism from school and eventually cause a decrease in student performance [3]. Different building types and their IEQ characteristics can be partly attributed to building age and construction materials. [4] Improving the energy performance of school buildings could result in the direct benefit of reduced utility costs and improving the indoor quality could improve the students' learning environment. Research also suggests that aging school facilities and inefficient equipment have a detrimental effect on academic performance that can be reversed when schools are upgraded. [5] Several studies have linked better lighting, thermal comfort, and air quality to higher test scores. [6, 7, 8] Another benefit of improving the energy efficiency of education buildings is the potential increase in market value through recognition of green building practice and labeling, such as that of a LEED or net zero energy building. In addition, because of their educational function, high-performance or energy-efficient buildings are particularly valuable for institution clients and local government. More and more high-performance buildings, net zero energy buildings, and positive energy buildings serve as living laboratories for educational purposes. Currently, educational/institutional buildings represent the largest portion of NZE (net zero energy) projects. Educational buildings comprise 36 percent of net zero buildings according to a 2014 National New Building Institute report. Of the 58 net zero energy educational buildings, 32 are used for kindergarten through grade 12 (K–12), 21 for higher education, and 5 for general education. [9] Finally, because educational buildings account for the third largest amount of building floor space in the United States, super energy-efficient educational buildings could provide other societal and economic benefits beyond the direct energy cost savings for three reasons: 1) educational buildings offer high visibility that can influence community members and the next generation of citizens, 2) success stories of the use of public funds that returns lower operating costs and healthier student learning environments provide documentation that can be used by others, and 3) this sector offers national and regional forums and associations to facilitate the transfer of best design and operational practices.


Author(s):  
Maurizio Cellura ◽  
Lucia Campanella ◽  
Giuseppina Ciulla ◽  
Mario Fontana ◽  
Valerio Lo Brano ◽  
...  