Performance assessment of a waste-heat driven CO2-based combined power and refrigeration cycle for dual-temperature refrigerated truck application

2021 ◽  
Vol 249 ◽  
pp. 114863
Author(s):  
Mingzhang Pan ◽  
Yan Zhu ◽  
Youcai Liang ◽  
Fulu Lu ◽  
Ruiping Zhi ◽  
...  
Energies ◽  
2021 ◽  
Vol 14 (23) ◽  
pp. 8192
Author(s):  
Alaa Attar ◽  
Mohamed Rady ◽  
Abdullah Abuhabaya ◽  
Faisal Albatati ◽  
Abdelkarim Hegab ◽  
...  

This article reports on an experimental analysis and performance assessment of using thermoelectric generators (TEGs) for waste heat recovery from residential vapor compression refrigeration systems. The analysis shows that there is a good opportunity for waste heat recovery using TEGs by de-superheating refrigerant after the compressor. Design and manufacturing of a de-superheater unit consisting of a tube and plate heat exchanger and thermoelectric generator modules (HE-TEGs) have been performed and integrated in an experimental test rig of R134a refrigeration cycle. Experimental assessment of the performance parameters, as compared to the basic refrigeration system, reveals that the overall coefficient of performance (COP) using HE-TEGs desuperheater unit increases by values ranging from 17% to 32% depending on the condenser and evaporator loads. Exergy analysis shows that the enhancement is attributed to reduction in the exergy destruction in the condenser and compressor due to lower values of condenser pressure and pressure ratio of the compressor. The output power of the HE-TEGs unit is found to be sufficient for driving the TEGs heat sinks air cooling fan, thus providing a passive de-superheating system without an additional external source of electricity. Further enhancement of the refrigeration cycle performance can be achieved by installation of additional HE-TEGs units.


Author(s):  
Ifeanyi Henry Njoku ◽  
Chika Oko ◽  
Joseph Ofodu

Abstract: This paper presents the thermodynamic performance analysis of an existing combined cycle power plant to be retrofitted with a waste heat driven aqua lithium bromide absorption refrigerator for cooling the inlet air streams to the compressor and air-cooled steam condenser. The power plant is located in the hot and humid tropical region of Nigeria, latitude 4°45′N and longitude 7°00′E. This was achieved by performing energy and exergy analysis of the integrated system. Using the operating data of the existing combined cycle power plant, the results of the analysis showed that by cooling the inlet air streams to 15oC at the compressors, and to 29oC at the air-cooled steam condenser, the net power output, thermal and exergy efficiencies of the combined cycle plant increased by 7.7%, 8.1% and 7.5% respectively while the plant total exergy destruction rate and specific fuel consumption dropped by 10.8% and 7.0% respectively. The stack flue gas exit temperature reduced from 126oC to 84oC in the absorption refrigerator, thus reducing the environmental thermal pollution. The COP and exergy efficiency of the refrigeration cycle was 0.60 and 27.0%, respectively. Results also show that the highest rate of exergy destruction in the combined cycle power plant occurred in the combustion chamber while the highest rate of exergy destruction in the absorption refrigeration cycle occurred in the evaporator followed by the absorber.


Sign in / Sign up

Export Citation Format

Share Document