Natural convection heat transfer from a heat sink with hollow/perforated circular pin fins

Energy ◽  
2010 ◽  
Vol 35 (7) ◽  
pp. 2870-2877 ◽  
Author(s):  
E.A.M. Elshafei
Author(s):  
Sunil V. Dingare ◽  
Narayan K. Sane ◽  
Ratnakar R. Kulkarni

Abstract Fins are commonly employed for cooling of electronic equipment, compressors, Internal Combustion engines and for heat exchange in various heat exchangers. In short fin (length to height ratio, L/H = 5) arrays used for natural convection cooling, a stagnation zone forms at the central portion and that portion is not effective for carrying away heat. An attempt is made to modify plate fin heat sink geometry (PFHS) by inserting pin fins in the channels formed between plate fins and a plate fin pin fin heat sink (PFPFHS) is constructed to address this issue. An experimental setup is developed to validate numerical model of PFPFHS. The three-dimensional elliptic governing equations were solved using a finite volume based computational fluid dynamics (CFD) code. Fluent 6.3.26, a finite volume flow solver is used for solving the set of governing equations for the present geometry. Cell count based on grid independence and extended domain is used to obtain numerical results. Initially, the numerical model is validated for PFHS cases reported in the literature. After obtaining a good agreement with results from the literature, the numerical model for PFHS is modified for PFPFHS and used to carry out systematic parametric study of PFPFHS to analyze the effects of parameters like fin spacing, fin height, pin fin diameter, number of pin fins and temperature difference between fin array and surroundings on natural convection heat transfer from PFPFHS. It is observed that it is impossible to obtain optimum performance in terms of overall heat transfer by only concentrating on one or two parameters. The interactions among all the design parameters must be considered. This thesis presents Experimental and Numerical study of natural convection heat transfer from horizontal rectangular plate fin and plate fin pin fin arrays. The parameters of study are fin spacing, temperature difference between the fin surface and ambient air, fin height, pin fin diameter, number of pin fins and method of positioning pin fins in the fin channel. Experimental set up is validated with horizontal plate standard correlations. Results are generated in the form of variation in average heat transfer coefficient (ha), base heat transfer coefficient (hb), average Nusselt number (Nua) and base Nusselt number (Nub). Total 512 cases are studied numerically and finally an attempt is made to correlate the Nusselt Number (Nu), Rayleigh Number (Ra), increase in percentage by inserting pin fins (% Area), ratios like spacing to height (S/H) and L/H obtained in the present study.


2011 ◽  
Vol 383-390 ◽  
pp. 6834-6839 ◽  
Author(s):  
Xiang Rui Meng ◽  
Xin Ling Ma ◽  
Ji Fu Lu ◽  
Xin Li Wei

In this paper the natural convection heat transfer performance of horizontal heat sink was studied by numerical simulation and experiment. The numerical simulation results show that there are some interesting features in the flow field of heat sink model. 1) Among the fins, the air vertically flows only through the fins in the symmetry center of heat sink while it horizontally flows through the fins in other area. 2) There is an air stagnation zone located at the fin root in the symmetry center of heat sink. These features both caused the decrease in heat transfer temperature difference and heat transfer area in fact. The natural convection heat transfer performance of heat sink is affected at last. In order to eliminate the air stagnation zone and change in the flow way of air, some holes were perforated at the fin root. These holes play its role. In this test, the heat transfer power of heat sink with seven holes has increased by 16.7% compared with the prototype.With the increase in the number of holes, the natural convection heat transfer power of heat sink also increases. But when the number of holes reaches to a value, the increase in the number of holes will not function properly.


2013 ◽  
Vol 284-287 ◽  
pp. 844-848
Author(s):  
Sheng Chung Tzeng ◽  
Tzer Ming Jeng ◽  
Zhi Ting Yeh

This study used metal porous medium heat sink to replace traditional cooling fins to form a high performance LED cooling system. The metal foamed material has high permeability and cooling area as large as several times of that of traditional fins. With a proper configuration design, it can improve the heat transfer capability of natural convection effectively. This study experimentally investigated the natural convection heat transfer characteristics of the annular metal foamed material, and determined the optimal configuration. The experimental results showed that 1) the heat transfer coefficient (h) increased with ΔT; 2) the (h) decreased as PPI (pores per inch) increased when the thickness (t) of the annular metal foams equaled 5 mm, but the (h) increased as PPI increased when t=11 and 14.5 mm; 3) the (h) increased and then decreased as (t) increased, and there was better heat transfer effect when t=11 mm as shown in the experimental data.