Effect of external post-tensioning on steel–concrete composite beams with partial connection

2021 ◽  
Vol 247 ◽  
pp. 113130
Author(s):  
Alaa A. El-Sisi ◽  
Ahmed I. Hassanin ◽  
Hesham F. Shabaan ◽  
Ahmed I. Elsheikh
2018 ◽  
Author(s):  
◽  
Ayman Elzohairy

[ACCESS RESTRICTED TO THE UNIVERSITY OF MISSOURI AT AUTHOR'S REQUEST.] The steel-concrete composite beam represents a structural system widely employed in both buildings and girder bridges. The coupling between steel beams and concrete flanges assures both economic and structural benefits because of quick construction of steel structures and large increase in stiffness due to the presence of concrete. Strengthening with external post-tensioning (PT) force is particularly effective and economical for long-span steel-concrete composite beams and has been employed with great success to increase the bending and shear resistance and correct excessive deflections. Applying external PT force to the steel-concrete composite beam is considered an active strengthening technique that can create permanent internal straining action in the beam which is opposite to the existing straining action due to the applied service loads. The most benefits of using this system of strengthening are an elastic performance to higher loads, higher ultimate capacity, and reduction in deformation under the applied loads. Under service loads, bridge superstructures are subjected to cyclic loads which may cause a premature failure due to fatigue. Therefore, fatigue testing is critical to evaluate existing design methods of steel-concrete composite beams. ... This research presents static and fatigue tests on four steel-concrete composite specimens to evaluate the effect of externally post-tensioned tendons on the ultimate strength and fatigue behavior of composite beams. Fatigue tests are conducted to a million cycles under a four-point bending test. In addition, final static tests are performed on fatigued specimens to evaluate the residual strength of the strengthened specimen. A numerical model is described to predict the fatigue response of the composite beam by considering the fatigue damage in the concrete flange. The accuracy of the developed numerical model is validated using the existing test data. The static test results indicate that the external post-tensioning force improves the flexural behavior of the strengthened specimen by increasing the beam capacity and reducing the tensile stress in the bottom flange of the steel beam. The fatigue results demonstrate that the external post-tensioning significantly decreases the strains in the shear connectors, concrete flange, and steel beam. The tendons demonstrated an excellent fatigue performance, with no indication of distress at the anchors.


2017 ◽  
Vol 20 (10) ◽  
pp. 1433-1450 ◽  
Author(s):  
Ayman El-Zohairy ◽  
Hani Salim

Strengthening of bridge superstructures composite beams with external post-tensioned tendons is a good technique for strengthening the existing structures. In this study, a numerical model is illustrated to study the nonlinear simulation of composite beams stiffened with externally post-tensioned tendons. The accuracy of the developed numerical model is validated using comparisons between the numerical and existing test data. The influence of various strengthening parameters is investigated, which include draped versus straight tendons, tendon length, the effect of post-tensioning on reinstating the flexural behavior of an overloaded beam, tendon eccentricity, and the degree of shear connection. A good agreement between the proposed model and the test data is obtained. The results demonstrate that at the same tendon eccentricity, the trapezoidal profile shows better behavior for the strengthened beams. However, more ductility is obtained when using the straight tendon profile. Applying post-tensioning through the beam of full length helps to reduce the creation of fatigue cracks, which always start at stress raisers, and subsequently increases the fatigue life of the composite beam. Also, the external post-tensioning effectively maintains the flexural behavior of the overloaded strengthened beam after unloading in comparison to the un-strengthened beam. It is observed that 80% degree of shear connection or higher is recommended to obtain the desired performance of the external post-tensioning force for strengthening composite beams.


Structures ◽  
2021 ◽  
Vol 29 ◽  
pp. 1119-1136
Author(s):  
Ahmed Ibrahim Hassanin ◽  
Hesham Fawzy Shabaan ◽  
Ahmed Ibrahim Elsheikh

2019 ◽  
Vol 7 (12) ◽  
pp. 1295-1307
Author(s):  
Xizhi Wu ◽  
Xueyou Huang ◽  
Xianjun Li ◽  
Yiqiang Wu

Sign in / Sign up

Export Citation Format

Share Document