An analytical psychometric function for the dual reference duo-trio (DRDT) method

2021 ◽  
pp. 104418
Author(s):  
Jian Bi ◽  
Hye-Seong Lee ◽  
Michael O'Mahony
1998 ◽  
Vol 21 ◽  
pp. 755
Author(s):  
Lynne A. Werner ◽  
Julianne M. Siebens

2012 ◽  
pp. 141-166
Author(s):  
Kenneth Knoblauch ◽  
Laurence T. Maloney

2012 ◽  
pp. 107-139
Author(s):  
Kenneth Knoblauch ◽  
Laurence T. Maloney

2010 ◽  
Vol 9 (8) ◽  
pp. 30-30 ◽  
Author(s):  
D. H. Foster ◽  
K. Zychaluk

2019 ◽  
Author(s):  
Ignacio Serrano-Pedraza ◽  
Kathleen Vancleef ◽  
William Herbert ◽  
Nicola Goodship ◽  
Maeve Woodhouse ◽  
...  

Bayesian staircases are widely used in psychophysics to estimate detection thresholds. Simulations have revealed the importance of the parameters selected for the assumed subject’s psychometric function in enabling thresholds to be estimated with small bias and high precision. One important parameter is the slope of the psychometric function, or equivalently its spread. This is often held fixed, rather than estimated for individual subjects, because much larger numbers of trials are required to estimate the spread as well as the threshold. However, if this fixed value is wrong, the threshold estimate can be biased. Here we determine the optimal slope to minimize bias and maximize precision when measuring stereoacuity with Bayesian staircases. We performed 2- and 4AFC disparity detection stereo experiments in order to measure the spread of the disparity psychometric function in human observers assuming a Logistic function. We found a wide range, between 0.03 and 3.5 log10 arcsec, with little change with age. We then ran simulations to examine the optimal spread using the real data. From our simulations and for three different experiments, we recommend selecting assumed spread values between the percentiles 60-80% of the population distribution of spreads (these percentiles can be extended to other type of thresholds). For stereo thresholds, we recommend a spread σ=1.7 log10 arcsec for 2AFC (slope 𝛽 = 4.3/log10 arcsec), and σ=1.5 log10 arcsec for 4AFC (𝛽 = 4.9/log10 arcsec). Finally, we compared a Bayesian procedure (ZEST using the optimal σ) with five Bayesian procedures that are versions of ZEST-2D, Psi, and Psi-marginal. In general, our recommended procedure showed the lowest threshold bias and highest precision.


1986 ◽  
Vol 29 (3) ◽  
pp. 400-406 ◽  
Author(s):  
M. J. Penner

For 7 patients with sensorineural hearing loss and tinnitus, pitch and loudness matches were made to the tinnitus. These matches were followed by measurement of three psychometric functions (probability of a correct response as a function of signal level) for pure tones, one in the presumed tinnitus region (i.e., at the average frequency matching the pitch of the tinnitus), one below the minimum frequency of the matches, and one above the maximum frequency of the matches. The data reveal (a) that pitch-loudness matches are usually quite variable and (b) that the slope of the psychometric function is flattest in the presumed tinnitus region. The first result is consistent with the idea that tinnitus is an unstable signal. The second result is consistent with the notion that the unstable tinnitus acts as a source of "internal" noise.


Sign in / Sign up

Export Citation Format

Share Document