scholarly journals Quenching distance, wall heat flux and CO/NO thermochemical states in the wall vicinity of laminar premixed biogas-hydrogen impinging flame

Fuel ◽  
2022 ◽  
Vol 307 ◽  
pp. 121849
Author(s):  
Zhilong Wei ◽  
Hu Liu ◽  
Zhenbin Chen ◽  
Zihao Liu ◽  
Haisheng Zhen
2008 ◽  
Vol 130 (12) ◽  
Author(s):  
David T. W. Lin ◽  
Hung Yi Li ◽  
Wei Mon Yan

An inverse solution scheme based on the conjugate gradient method with the minimization of the object function is presented for estimating the unknown wall heat flux of conjugated forced convection flows between two corotating disks from temperature measurements acquired within the flow field. The validity of the proposed approach is demonstrated via the estimation of three time- and space-dependent heat flux profiles. A good agreement is observed between the estimated results and the exact solution in every case. In general, the accuracy of the estimated results is found to improve as the temperature sensors are moved closer to the unknown boundary surface and the error in the measured temperature data is reduced.


Author(s):  
Arif Hussain ◽  
Muhammad Yousaf Malik ◽  
Mair Khan ◽  
Taimoor Salahuddin

Purpose The purpose of current flow configuration is to spotlights the thermophysical aspects of magnetohydrodynamics (MHD) viscoinelastic fluid flow over a stretching surface. Design/methodology/approach The fluid momentum problem is mathematically formulated by using the Prandtl–Eyring constitutive law. Also, the non-Fourier heat flux model is considered to disclose the heat transfer characteristics. The governing problem contains the nonlinear partial differential equations with appropriate boundary conditions. To facilitate the computation process, the governing problem is transmuted into dimensionless form via appropriate group of scaling transforms. The numerical technique shooting method is used to solve dimensionless boundary value problem. Findings The expressions for dimensionless velocity and temperature are found and investigated under different parametric conditions. The important features of fluid flow near the wall, i.e. wall friction factor and wall heat flux, are deliberated by altering the pertinent parameters. The impacts of governing parameters are highlighted in graphical as well as tabular manner against focused physical quantities (velocity, temperature, wall friction factor and wall heat flux). A comparison is presented to justify the computed results, it can be noticed that present results have quite resemblance with previous literature which led to confidence on the present computations. Originality/value The computed results are quite useful for researchers working in theoretical physics. Additionally, computed results are very useful in industry and daily-use processes.


1966 ◽  
Vol 88 (2) ◽  
pp. 214-222 ◽  
Author(s):  
W. T. Lawrence ◽  
J. C. Chato

A numerical method was developed for the calculation of entrance flows in vertical tubes for the cases of upflow or downflow and constant wall heat flux or constant wall temperature. The solutions were in excellent agreement with experimental data obtained with water flowing upward in a vertical heated tube. The results show that both the density and the viscosity have to be treated as nonlinear functions of temperature. Consequently, for the constant heat flux condition, the velocity and temperature profiles constantly change and never reach “fully developed” states. The transition to turbulent flow was also studied. The experimental measurements demonstrated that the transition process depends on the developing velocity profiles. For the constant heat flux case, transition will always occur at some axial position. For a given entrance condition, the distance to transition is fixed by the fluid flow rate and the wall heat flux. For the experimental results, a tentative transition criterion was obtained, which depends only on the velocity profile shape, fluid viscosity, and the entrance Reynolds number.


Author(s):  
Tânia S. Cação Ferreira ◽  
Tony Arts

An investigation of thermal effects on bypass transition was conducted on the highly-loaded turbine guide vane LS89 in the short-duration isentropic Compression Tube (CT-2) facility at the von Karman Institute for Fluid Dynamics (VKI). Measurements from high response surface-mounted thin films coupled with analog circuits provided the time-resolved wall heat flux history whereas pneumatic probes, differential pressure transducers and thermocouples allowed the accurate definition of the inlet and outlet flow conditions. The gas-to-wall temperature ratio, ranging from 1.11 to 1.55, was varied by changing the inlet total temperature. The isentropic exit Mach number ranged from 0.90 to 1.00 and the global freestream turbulence intensity value was set at 0.8, 3.9 and 5.3%. The isentropic exit Reynolds number was kept at 106. The onset of transition was tracked through the wall heat flux signal fluctuations. Within the present operating conditions, no significant effect of the gas/wall temperature ratio was put in evidence. At the present (design) transonic exit conditions, the local free-stream pressure gradient appears to remain the main driver of the onset of transition. A wider range of operating conditions must be considered to draw final conclusions.