scholarly journals Mo1293 USEFULNESS OF HISTOLOGICAL ASSESSMENT WITH EUS-GUIDED FINE NEEDLE BIOPSY USING A NEW CORE NEEDLE IN PANCREATIC DISEASES

2018 ◽  
Vol 87 (6) ◽  
pp. AB432-AB433 ◽  
Author(s):  
Takuya Ishikawa ◽  
Yoshiki Hirooka ◽  
Hiroki Kawashima ◽  
Eizaburo Ohno ◽  
Hiroki Suhara ◽  
...  
2019 ◽  
Vol 2019 ◽  
pp. 1-8 ◽  
Author(s):  
Takuya Ishikawa ◽  
Hiroki Kawashima ◽  
Eizaburo Ohno ◽  
Hiroyuki Tanaka ◽  
Daisuke Sakai ◽  
...  

Background and Aims. Several studies have shown the benefits of endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) using a Franseen needle for histological assessment. However, studies focusing on pancreatic diseases are limited and the safety of this method has not been well assessed. We aimed to assess the current status and issues of EUS-FNB in the diagnosis of pancreatic diseases. Materials and Methods. We retrospectively reviewed 87 consecutive EUS-FNB specimens using either a 22-gauge Franseen needle (Group A, N = 51) or a conventional 22-gauge fine-needle aspiration needle (Group B, N = 36) for pancreatic diseases, and the diagnostic accuracy and safety were compared. Final diagnoses were obtained based on surgical pathology or a minimum six-month clinical follow-up. Results. Although the diagnostic accuracy for malignancy was 96.1% in Group A versus 88.9% in Group B, with no statistically significant difference (P = 0.19), the median sample area was significantly larger in Group A (4.07 versus 1.31mm2, P < 0.0001). There were no differences between the two needles in the locations from which the specimens were obtained. Adverse events occurred in one case (2%) in Group A (mild pancreatitis) and none in Group B with no statistical significance (P = 0.586). Although there was no case of bleeding defined as adverse events, 2 cases in Group A showed active bleeding during the procedure with increase in the echo-free space, which required CT scanning to rule out extravasation. Eventually, the bleeding stopped spontaneously. Conclusions. Given its guaranteed ability to obtain core specimens and comparable safety, and although the risk of bleeding should be kept in mind, EUS-FNB using a Franseen needle is likely to become a standard procedure for obtaining pancreatic tissue in the near future.


2015 ◽  
Vol 54 (03) ◽  
pp. 101-105 ◽  
Author(s):  
F. A. Verburg

SummaryThyroid surgery is one of the more common surgical procedures in Germany. This is in contrast with the situation in some other countries, where this procedure is performed comparatively rarely. In this paper the number of thyroid surgeries in Germany is compared with other western countries (Netherlands, USA, England). In contrast to e. g. the USA and England the number of thyroid surgeries in Germany is declining, however with approximately 109/100 000/year in 2012 is still elevated (Netherlands: 16/100 000/year, USA: at least 42/100 000/year, England: at least 27/100 000/year).Possible contributing factors to this higher number of thyroid surgeries in Germany are explored. These factors include iodine deficiency, the frequent use of advanced diagnostics such as ultrasound, insufficient use of preoperative diagnostic measures such as fine needle biopsy and the practice of “defensive medicine”. How much each of these factors contributes is however unclear.


Sign in / Sign up

Export Citation Format

Share Document