scholarly journals B-PO02-212 INTERVENTRICULAR SEPTAL HEMATOMA COMPLICATING LEFT BUNDLE BRANCH PACING LEAD IMPLANTATION

Heart Rhythm ◽  
2021 ◽  
Vol 18 (8) ◽  
pp. S185
Author(s):  
Weijian Huang ◽  
Rujie Zheng ◽  
Shengjie Wu
Keyword(s):  
2010 ◽  
Vol 6 (1) ◽  
pp. 83
Author(s):  
Jagmeet P Singh ◽  

Cardiac resynchronisation therapy (CRT) has gained widespread acceptance as a safe and effective therapeutic strategy for congestive heart failure (CHF) refractory to optimal medical therapy. The use of implantable devices has substantially altered the natural history of systolic heart failure. These devices exert their physiological impact through ventricular remodelling, associated with a reduction in left ventricular (LV) volumes and an improvement in ejection fraction (EF). Several prospective randomised studies have shown that this in turn translates into long-term clinical benefits such as improved quality of life, increased functional capacity and reduction in hospitalisation for heart failure and overall mortality. Despite these obvious benefits, there remain more than a few unresolved concerns, the most important being that up to one-third of patients treated with CRT do not derive any detectable benefit. There are several determinants of successful delivery and response to CRT, including selecting the appropriate patient, patient-specific optimal LV pacing lead placement and appropriate post-implant device care and follow-up. This article highlights the importance of collectively working on all of these aspects of CRT to enhance and maximise response.


2011 ◽  
Vol 3 (1) ◽  
pp. 74
Author(s):  
Kathy L Lee ◽  

Cardiac pacemakers have been the standard therapy for patients with bradyarrhythmias for several decades. The pacing lead is an integral part of the system, serving as a conduit for the delivery of energy pulses to stimulate the myocardium. However, it is also the Achilles’ heel of pacemakers, being the direct cause of most device complications both acutely during implant and chronically years afterwards. Leadless pacing with ultrasound-mediated energy has been demonstrated in animals and humans to be safe and feasible in acute studies. Implantable defibrillators revolutionised the treatment and prevention of sudden cardiac death. Subcutaneous implantable defibrillators have been under development for more than 10 years. A permanent implantable system has been shown to be feasible in treating induced and spontaneous ventricular tachyarrhythmias. These developments and recent advances in pacing and defibrillation will arouse further interest in the research and development of leadless cardiac implantable electronic devices.


2016 ◽  
Vol 32 (6) ◽  
pp. 830.e5-830.e6
Author(s):  
Pierre-Louis Nadeau ◽  
Jean Champagne ◽  
Franck Molin ◽  
Jean-François Sarrazin ◽  
Gilles O’Hara ◽  
...  

2021 ◽  
Vol 30 ◽  
pp. S256-S257
Author(s):  
R. O'Driscoll ◽  
Q. Yang ◽  
M. Zhu ◽  
G. McKay ◽  
R. Tan

Heart Rhythm ◽  
2021 ◽  
Vol 18 (8) ◽  
pp. S294-S295
Author(s):  
Martin C. Burke ◽  
Adrian Ebner ◽  
Michael Husby ◽  
DonE. Scheck ◽  
Angel Cardeno ◽  
...  

2021 ◽  
pp. 263246362097804
Author(s):  
Vanita Arora ◽  
Pawan Suri

Anatomy and physiology are the basis of human body functioning and as we have progressed in management of various diseases, we have understood that physiological intervention is always better than an anatomical one. For more than 50 years, a standard approach to permanent cardiac pacing has been an anatomical placement of transvenous pacing lead at the right ventricular apex with a proven benefit of restoring the rhythm. However, the resultant ventricular dyssynchrony on the long-term follow-up in patients requiring more than 40% ventricular pacing led to untoward side effects in the form of heart failure and arrhythmias. To counter such adverse side effects, a need for physiological cardiac pacing wherein the electrical impulse be transmitted directly through the normal conduction system was sought. His bundle pacing (HBP) with an intriguing alternative of left bundle branch pacing (LBBP) is aimed at restoring such physiological activation of ventricles. HBP is safe, efficacious, and feasible; however, localization and placement of a pacing lead at the His bundle is challenging with existing transvenous systems due to its small anatomic size, surrounding fibrous tissue, long-learning curve, and the concern remains about lead dislodgement and progressive electrical block distal to the HBP lead. In this article, we aim to take the reader through the challenging journey of HBP with focus upon the hardware and technique, selective versus nonselective HBP, indications and potential disadvantages, and finally the future prospects.


2021 ◽  
Vol 30 ◽  
pp. S164
Author(s):  
C. Chow ◽  
P. Crane ◽  
H. Lim ◽  
U. Mohamed

2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
K Miyajima ◽  
T Urushida ◽  
K Ito ◽  
F Kin ◽  
A Okazaki ◽  
...  

Abstract Background Right ventricular (RV) septal pacing is often selected to preserve a more physiologic ventricular activation. But the pacing leads are not always located in true septal wall, rather in hinge or free wall in some cases with the conventional stylet-guided lead implantation. In recent years, new guiding catheter systems has attracted attention as a solution to that problem. Objective The aim of this study is to investigate that true ventricular sepal pacing can be achieved by use of the new guiding catheter system for pacing lead. Methods We enrolled 198 patients who underwent RV septal lead implantation and computed tomography (CT) after pacemaker implantation. 16 cases were used delivery catheter (Delivery), and 182 cases were used stylet for targeting ventricular septum (Conventional). We analyzed the lead locations with CT, and evaluated capture thresholds, R-wave amplitudes, lead impedances and 12-lead electrocardiogram findings one month after implantation. Results All cases of delivery catheter group had true septal lead positions (Delivery; 100% vs Conventional; 44%, p<0.01). Capture thresholds and lead impedances had not significant differences between between two groups (0.65±0.15V vs 0.60±0.15V, p=0.21, 570±95Ω vs 595±107Ω, p=0.39, respectively). R-wave amplitudes were significantly higher in delivery catheter group (13.0±4.8mV vs 10±4.6mV, p<0.01). Paced QRS durations were shorter in delivery catheter group (128±16ms vs 150±21ms, p<0.01). Conclusions The delivery catheter system designated for pacing lead can contribute to select the true ventricular septal sites and to attain the more physiologic ventricular activation. Funding Acknowledgement Type of funding source: None