Posterior fascicular block obscuring the right bundle branch block pattern

2012 ◽  
Vol 159 (3) ◽  
pp. e51-e52
Author(s):  
Paolo Alboni ◽  
Lorella Gianfranchi ◽  
Sabrina Bressan
Circulation ◽  
1974 ◽  
Vol 50 (6) ◽  
pp. 1105-1113 ◽  
Author(s):  
EHUD KRONGRAD ◽  
STEPHEN E. HEFLER ◽  
FREDERICK O. BOWMAN ◽  
JAMES R. MALM ◽  
BRIAN F. HOFFMAN

2020 ◽  
Author(s):  
João Ferreira ◽  
Célia Marques Domingues ◽  
Susana Isabel Costa ◽  
Maria Fátima Franco Silva ◽  
Lino Manuel Martins Gonçalves

Abstract Background Implantable cardiac defibrillators (ICD) are a popular and effective option in heart failure with left ventricular systolic dysfunction patients. Although frequently underdiagnosed, inadvertent malposition can lead to endocardial damage and thrombotic events. As ICD implants tend to increase in the following years, the recognition of their complications is critical. Case presentation The authors present a case of a 64-year-old woman with advanced heart failure and ICD malposition. This accidental discovery was denounced by the presence of a right bundle branch block pattern and later confirmed by echocardiography which showed the lead tip in contact with the mid segment of the left ventricular antero-lateral wall. As the patient hospitalisation was complicated with refractory ascites and cardiogenic shock, she underwent cardiac transplantation, with no recurrence of heart failure symptoms. Conclusions An electrocardiogram showing a right bundle branch block pattern during VVI pacing should arise the suspicion of inadvertent placement of a pacing/ICD lead. The many facets of echocardiography should be used for the diagnosis of this complication, as they were paramount in this case, as highlighted.


2012 ◽  
Vol 34 (2) ◽  
pp. 86-88 ◽  
Author(s):  
I. Fernandez-Lozano ◽  
J. Brugada

Author(s):  
Ruohan Zhao ◽  
Feng Xiong ◽  
Xiaoqi Deng ◽  
Shuzhen Wang ◽  
Chunxia Liu ◽  
...  

Aim To evaluate ventricular synchronization and function in patients with right bundle-branch block after left bundle-branch-area pacing (LBBAP) by echocardiography. Methods Forty patients who successfully received LBBAP were selected and divided into the right bundle-branch block group (RBBB group) and the non-RBBB group by pre-operation ECG. Echocardiography and follow-up were performed 1 month after operation. Interventricular synchronization was evaluated by tissue Doppler (TDI), tissue mitral annular displacement (TMAD), and interventricular mechanical delay (IVMD). The ventricular longitudinal strain and the standard deviation of peak time of longitudinal strain were analyzed by two-dimensional speckle tracking imaging (2D-STI) to evaluate intraventricular synchronization and ventricular function. Results (1) The deviation of systolic time to the peak of the tricuspid and mitral valves, namely ΔPTTV-MV measured by TMAD and ΔTsTV-MV measured by TDI, were statistically different between the two groups (P < 0.05). (2) Compared with the non-RBBB group, there were no statistically significant differences in longitudinal strain (LS), peak strain time, standard deviation of peak strain time (SDt), and global longitudinal strain (GLS) in the right and left ventricle in the RBBB group (P > 0.05). Conclusion Echocardiography technology including 2D-STI, TDI, and TMAD can effectively analyze interventricular synchronization, intraventricular synchronization, and ventricular function. Although the movement of the right ventricular myocardium in the RBBB group treatment was slightly later than that of the left ventricular myocardium after LBBAP, LBBAP is still an effective pacing therapy for RBBB patients with pacing indication.


Heart India ◽  
2013 ◽  
Vol 1 (2) ◽  
pp. 57
Author(s):  
MangalachulliPottammal Ranjith ◽  
Kalathingathodika Sajeer ◽  
ChakanalilGovindan Sajeev ◽  
Cicy Bastian ◽  
Vellani Haridasan ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document