Numerical simulation of the turbulent air flow in the narrow channel with a heated wall and a spherical dimple placed on it for vortex heat transfer enhancement depending on the dimple depth

Author(s):  
S.A. Isaev ◽  
A.V. Schelchkov ◽  
A.I. Leontiev ◽  
P.A. Baranov ◽  
M.E. Gulcova
Energies ◽  
2019 ◽  
Vol 12 (5) ◽  
pp. 813 ◽  
Author(s):  
Parkpoom Sriromreun ◽  
Paranee Sriromreun

This research was aimed at studying the numerical and experimental characteristics of the air flow impinging on a dimpled surface. Heat transfer enhancement between a hot surface and the air is supposed to be obtained from a dimple effect. In the experiment, 15 types of test plate were investigated at different distances between the jet and test plate (B), dimple diameter (d) and dimple distance (Er and Eθ). The testing fluid was air presented in an impinging jet flowing at Re = 1500 to 14,600. A comparison of the heat transfer coefficient was performed between the jet impingement on the dimpled surface and the flat plate. The velocity vector and the temperature contour showed the different air flow characteristics from different test plates. The highest thermal enhancement factor (TEF) was observed under the conditions of B = 2 d, d = 1 cm, Er= 2 d, Eθ = 1.5 d and Re = 1500. This TEF was obtained from the dimpled surface and was 5.5 times higher than that observed in the flat plate.


2019 ◽  
Vol 2019.68 (0) ◽  
pp. 416
Author(s):  
Shichao Yu ◽  
Tatsuya Tsuneyoshi ◽  
Yukinori Hamaji ◽  
Sachiko Yoshihashi ◽  
Takahiro Ito ◽  
...  

2017 ◽  
Vol 21 (2) ◽  
Author(s):  
Dong-Yang Li ◽  
Hongna Zhang ◽  
Jian-Ping Cheng ◽  
Xiao-Bin Li ◽  
Feng-Chen Li ◽  
...  

Author(s):  
Yi-Hsuan Huang ◽  
Chiao-Hsin Chen ◽  
Yao-Hsien Liu

Heat transfer of air/water mist flow in a single-side heated vertical duct was experimentally investigated. The mist flow was produced by introducing fine dispersed water droplets into the air stream, and the water–air mass flow ratios were up to 15%. The Reynolds numbers of the air flow were 7900, 16,000, and 24,000. The rib spacing-to-height ratios were 10 and 20 in the current study. Mist flow cooling achieved higher heat transfer rates mainly because of the droplet deposition and liquid film formation on the heated surface. The heat transfer enhancement on the smooth surface by the mist flow was 4–6 times as high as the air flow. On the ribbed surface, a smaller rib spacing of 10 was preferred for air cooling, since the heat transfer enhancement by the flow reattachment was better utilized. However, the rib-induced secondary flow blew away the liquid films on the surface, and the heat transfer enhancement was degraded near the reattachment region for the mist cooling. A larger rib spacing-to-height ratio of 20 thus achieved higher heat transfer because of the liquid film formation beyond the reattachment region. The heat transfer enhancement on the ribbed surface using mist flow was 2.5–3.5 times as high as the air flow. The friction factor of the mist flow was two times as high as the air flow in the ribbed duct.