scholarly journals Silicone elastomer formulations for improved performance of a multipurpose vaginal ring releasing dapivirine and levonorgestrel

Author(s):  
Yahya H. Dallal Bashi ◽  
Diarmaid J. Murphy ◽  
Clare F. McCoy ◽  
Peter Boyd ◽  
Leeanne Brown ◽  
...  
2013 ◽  
Vol 48 (3) ◽  
pp. 406-415 ◽  
Author(s):  
Susan M. Fetherston ◽  
Peter Boyd ◽  
Clare F. McCoy ◽  
Marcella C. McBride ◽  
Karen-Leigh Edwards ◽  
...  

2012 ◽  
Vol 68 (2) ◽  
pp. 394-403 ◽  
Author(s):  
S. M. Fetherston ◽  
L. Geer ◽  
R. S. Veazey ◽  
L. Goldman ◽  
D. J. Murphy ◽  
...  

PLoS ONE ◽  
2018 ◽  
Vol 13 (5) ◽  
pp. e0196904 ◽  
Author(s):  
Annaléne Nel ◽  
Janine Martins ◽  
Linda-Gail Bekker ◽  
Gita Ramjee ◽  
Gileard Masenga ◽  
...  

2013 ◽  
Vol 68 (6) ◽  
pp. 1451-1451
Author(s):  
S. M. Fetherston ◽  
L. Geer ◽  
R. S. Veazey ◽  
L. Goldman ◽  
D. J. Murphy ◽  
...  

2017 ◽  
Vol 106 (8) ◽  
pp. 2015-2025 ◽  
Author(s):  
Clare F. McCoy ◽  
Diarmaid J. Murphy ◽  
Peter Boyd ◽  
Tiffany Derrick ◽  
Patrick Spence ◽  
...  

2012 ◽  
Vol 67 (8) ◽  
pp. 2005-2012 ◽  
Author(s):  
M. J. Keller ◽  
A. M. Malone ◽  
C. A. Carpenter ◽  
Y. Lo ◽  
M. Huang ◽  
...  

2014 ◽  
Vol 30 (S1) ◽  
pp. A140-A140 ◽  
Author(s):  
Clare McCoy ◽  
Peter Boyd ◽  
Susan Fetherston ◽  
Ian Major ◽  
Diarmaid Murphy ◽  
...  

Author(s):  
Gertrude. F. Rempfer

Optimum performance in electron and ion imaging instruments, such as electron microscopes and probe-forming instruments, in most cases depends on a compromise either between imaging errors due to spherical and chromatic aberrations and the diffraction error or between the imaging errors and the current in the image. These compromises result in the use of very small angular apertures. Reducing the spherical and chromatic aberration coefficients would permit the use of larger apertures with resulting improved performance, granted that other problems such as incorrect operation of the instrument or spurious disturbances do not interfere. One approach to correcting aberrations which has been investigated extensively is through the use of multipole electric and magnetic fields. Another approach involves the use of foil windows. However, a practical system for correcting spherical and chromatic aberration is not yet available.Our approach to correction of spherical and chromatic aberration makes use of an electrostatic electron mirror. Early studies of the properties of electron mirrors were done by Recknagel. More recently my colleagues and I have studied the properties of the hyperbolic electron mirror as a function of the ratio of accelerating voltage to mirror voltage. The spherical and chromatic aberration coefficients of the mirror are of opposite sign (overcorrected) from those of electron lenses (undercorrected). This important property invites one to find a way to incorporate a correcting mirror in an electron microscope. Unfortunately, the parts of the beam heading toward and away from the mirror must be separated. A transverse magnetic field can separate the beams, but in general the deflection aberrations degrade the image. The key to avoiding the detrimental effects of deflection aberrations is to have deflections take place at image planes. Our separating system is shown in Fig. 1. Deflections take place at the separating magnet and also at two additional magnetic deflectors. The uncorrected magnified image formed by the objective lens is focused in the first deflector, and relay lenses transfer the image to the separating magnet. The interface lens and the hyperbolic mirror acting in zoom fashion return the corrected image to the separating magnet, and the second set of relay lenses transfers the image to the final deflector, where the beam is deflected onto the projection axis.


Sign in / Sign up

Export Citation Format

Share Document