Dosimetric effects within target and organs at risk of interfractional patient mispositioning in left breast cancer radiotherapy

2004 ◽  
Vol 59 (3) ◽  
pp. 861-871 ◽  
Author(s):  
Guido Baroni ◽  
Cristina Garibaldi ◽  
Marco Scabini ◽  
Marco Riboldi ◽  
Gianpiero Catalano ◽  
...  
2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Kai J. Borm ◽  
Yannis Junker ◽  
Mathias Düsberg ◽  
Michal Devečka ◽  
Stefan Münch ◽  
...  

AbstractThe current study aims to assess the effect of cone beam computed tomography (CBCT) frequency during adjuvant breast cancer radiotherapy with simultaneous integrated boost (SIB) on target volume coverage and dose to the organs at risk (OAR). 50 breast cancer patients receiving either non-hypofractionated or hypofractionated radiotherapy after lumpectomy including a SIB to the tumor bed were selected for this study. All patients were treated in volumetric modulated arc therapy (VMAT) technique and underwent daily CBCT imaging. In order to estimate the delivered dose during the treatment, the applied fraction doses were recalculated on daily CBCT scans and accumulated using deformable image registration. Based on a total of 2440 dose recalculations, dose coverage in the clinical target volumes (CTV) and OAR was compared depending on the CBCT frequency. The estimated delivered dose (V95%) for breast-CTV and SIB-CTV was significantly lower than the planned dose distribution, irrespective of the CBCT-frequency. Between daily CBCT and CBCT on alternate days, no significant dose differences were found regarding V95% for both, breast-CTV and SIB-CTV. Dose distribution in the OAR was similar for both imaging protocols. Weekly CBCT though led to a significant decrease in dose coverage compared to daily CBCT and a small but significant dose increase in most OAR. Daily CBCT imaging might not be necessary to ensure adequate dose coverage in the target volumes while efficiently sparing the OAR during adjuvant breast cancer radiotherapy with SIB.


2018 ◽  
Vol 20 (11) ◽  
pp. 1430-1438 ◽  
Author(s):  
L. Darvish ◽  
M. Ghorbani ◽  
S. Hosseini Teshnizi ◽  
N. Roozbeh ◽  
F. Seif ◽  
...  

2016 ◽  
Vol 119 ◽  
pp. S795-S796
Author(s):  
A. Fozza ◽  
L. Berta ◽  
S. Aimonetto ◽  
F. Migliaccio ◽  
A. Peruzzo Cornetto ◽  
...  

2021 ◽  
Author(s):  
Samsun - ◽  
Muhammad Arif Arif ◽  
Gregorius Septayudha Septayudha

Abstract In terms of breast cancer radiation treatment, it has radiation using the 3D-Conformal Radiotherapy (3D-CRT) technique and the continuation of the 3D-CRT technique, namely the Intensity Modulated Radiation Therapy (IMRT) technique. This study aims to evaluate the dosage aspects of PTV and OAR between the 3D-CRT and IMRT techniques in cases of left breast cancer with hypofractionation using the Deep Inspiration Breath Hold (DIBH) method using the Conformity Index (CI) and Homogeneity Index (H.I.) and H.I. organ at risk uses tolerance limits. This type of research is comparative quantitative with ten samples with primary data conducted at Siloam T.B. Hospital. Simatupang from November 2019 to April 2020. The research was carried out in the form of radiation planning with 3D-CRT techniques and IMRT techniques, and the results of planning both techniques were evaluated between 3D-CRT techniques and IMRT techniques through PTV evaluations using CI and H.I. values. Furthermore, the organs at risk use tolerance limits on each organ. The results showed the assessment between 3D-CRT and IMRT on PTV and organs at risk received different doses. The PTV shows the CI value, which is almost the same as the difference of 0.034, and there is a slight difference in H.I. with an average value in the IMRT technique of 0.07 and 3D-CRT of 0.11, and it can be seen that the IMRT is slightly superior because the excellent H.I. value is the closest to 0. Then at the dose of organ at risk received by the sample, the 3D-CRT technique is slightly superior by obtaining a lower dose that obtains the difference in the heart by 0.53%, lung by 3.46%, spinal cord by 6.51 Gy, esophagus at 4.5 Gy, and larynx at 5.18 Gy.


2020 ◽  
Author(s):  
Nadia Pasinetti ◽  
Lilia Bardoscia ◽  
Luigi Spiazzi ◽  
Barbara Ghedi ◽  
Sara Pedretti ◽  
...  

Abstract Background: Radiotherapy (RT) improves local control and survival in breast cancer (BC) patients. However, risk of heart and lung side effects after post-operative left breast RT for breast cancer remain despite technological and technical RT advances. In a retrospective cohort we investigated if Active Breathing Coordinator (ABC) device can reduce risk of cardiopulmonary morbidity.Methods: we performed two different dosimetric analyses by Normal Tissue Complication Probability (NTCP) and Bio-Dose-Volume Histograms (Bio-DVH) in order to determine whether left breast RT using moderating deep inspiration breath-hold (mDIBH) with the Active Breathing Coordinator (ABC) device, may significantly reduce heart, left anterior descending coronary artery (LADCA) and lung radiation exposure during left breast RT performed with 3d-CRT technique.Results: Several dosimetric parameters were used in the present study to compare the treatment plans generated by FB and mDIBH images of sixty-nine consecutive patients treated between May 2012 and April 2016 at the Istituto del Radio Radiation Oncology Dept. All data derived by Bio-DVH and the heart NTCP calculation showed that ABC led to significant sparing of organs at risk compared with FB, expecially for the heart and LADCA. We also showed that the mDIBH technique significantly reduced left lung dose: in fact, through inflation, only low density lung tissue remains within the tangential field, thus avoiding its deterioration.Conclusions: Use of mDIBH gives a real advantage on breast cancer RT by reducing the radiation to the organs at risk (OARs) and consequently, the risk of cardiac and pulmonary late side effects.


Sign in / Sign up

Export Citation Format