Loop Anchor Tension Band Technique for Patella Fractures Lowers the Rate of Kirschner Migration

Injury ◽  
2020 ◽  
Author(s):  
Shu-Hsin Yao ◽  
Shu-Fan Lin ◽  
Chang-Hao Lin ◽  
Chun-Ho Chen
2010 ◽  
Vol 96 (5) ◽  
pp. 579-582 ◽  
Author(s):  
K.A. Lefaivre ◽  
P.J. O’Brien ◽  
H.M. Broekhuyse ◽  
P. Guy ◽  
P.A. Blachut

2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Puripun Jirangkul ◽  
Arkaphat Kosiyatrakul

Abstract Background Modified tension band fixation has become commonly used for transverse patella fractures. The conventional stainless steel wire provides sufficient stability but may be associated with complications. Objective The study aimed to evaluate the effectiveness of a new modified tension band fixation technique for transverse patella fractures using a nonabsorbable suture. Material and methods We present the result of a prospective series using a nonabsorbable suture (FiberWire) for transverse patella fractures. The mean follow-up period totaled 12 months. A total of 16 patients were evaluated by radiographic and clinical review. The postoperative clinical evaluation employed Lysholm and Böstman scores. Result All clinical results on follow-up were good to excellent. Minimal intra-articular joint stepping and further fracture displacement were recorded. No patient needed re-operation, and functional outcomes of the knee were satisfactory. No significant differences were found between the injured and contralateral knee range of motion. No symptomatic implants and skin complications were noted, and all fractures were completed heal within 15 weeks. Conclusion FiberWire provided sufficient stability and reduced postoperative complications. The results proved appropriate, and the technique has merit, as it obviates the need for re-operation.


2017 ◽  
Vol 26 (4) ◽  
pp. 615-619 ◽  
Author(s):  
quan-ming zhao ◽  
Xiao-feng Gu ◽  
Li Cheng ◽  
De-hong Feng

2020 ◽  
Vol 11 (4) ◽  
pp. 7985-7989
Author(s):  
Senthil Loganathan ◽  
Raghavendran B ◽  
Thiyagarajan U ◽  
Pradeep J

Patella fractures accounts for 1% of all skeletal injuries.  Patella fractures usually need to be treated with accurate reduction and fixation to obtain optimal knee function. Improper reduction of the articular fragments leads to complications like arthritis and quadriceps dysfunction. Tension band wiring and pasting are commonly performed fixation methods. Tension band wiring with K-wires is associated with wire prominence and soft tissue irritation. Cannulated cancellous screw fixation of the fracture and tension band wiring through the cannulated screws avoid the complication of wire migration and breakage.   In our study, we fixed these fractures with cannulated cancellous screws and tension band. This is a prospective study done in SRMC from 2012-2017. A total of 17 Patients with transverse patella fracture are taken into a study, 4mm cannulated cancellous screws with 18 mm stainless steel wire is used for anterior tension band wiring. Extensor retinaculum closure is done for all these patients. All patients had excellent knee function, according to KSS. There was no case of implant prominence or soft issue irritation in any of these patients. One patient had extensor lag. Cannulated cancellous screw with anterior tension band wiring is a reliable, effective and reproducible technique in treating transverse patella fractures.


2016 ◽  
Vol 22 ◽  
pp. 2736-2741 ◽  
Author(s):  
Zichao Xue ◽  
Hui Qin ◽  
Haoliang Ding ◽  
Haitao Xu ◽  
Zhiquan An

2019 ◽  
Vol 27 (3) ◽  
pp. 230949901987401
Author(s):  
Fasheng Wang ◽  
Tianyi David Luo ◽  
Chunyong Chen ◽  
Yun Xie ◽  
Zhangxiong Lin ◽  
...  

Purpose: The purpose of this study was to assess the outcomes in a series of patients, who underwent cerclage and figure-of-eight tension band wiring using a single titanium cable for comminuted patellar fractures. Methods: We describe a modified tension band technique using a single titanium cable to create an ellipsoidal cap structure that combines the circumferential and figure-of-eight wrapping in the fixation of closed Association for the Study of Internal Fixation/Orthopaedic Trauma Association 34C2 and 34C3 patellar fractures. We retrospectively reviewed 25 patients (16 males and 9 females, mean age 54 years) who underwent the described fixation technique between 2015 and 2017. Postoperative function was evaluated using the Böstman score. Results: At the mean follow-up of 25 months (range 17–39 months), the mean Böstman score was 27.3 ± 2.6 points (range 23–30). Eighteen patients (72%) had excellent results (score ≥28); seven patients (28%) had good results (score 20–27); and no patients had an unsatisfactory result (score < 20). All surgical incisions healed without major wound complications. Two patients reported minor complications (soft tissue irritation, cellulitis). No patients demonstrated loss of reduction or implant failure during the follow-up period. Conclusion: The modified anterior ellipsoidal cap tension band using a single titanium cable created an effective tension band structure in the treatment of comminuted patella fractures. It is a simple operative technique that produced a stable fixation construct, which allowed early functional rehabilitation and weight-bearing with a high rate of excellent outcomes at 2 years after surgery.


2019 ◽  
Vol 33 (4) ◽  
pp. e143-e150 ◽  
Author(s):  
Jae-Woo Cho ◽  
William T. Kent ◽  
Won-Tae Cho ◽  
Jin-Kak Kim ◽  
Ki-Ho Moon ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document