Fixation of Closed Transverse Patella Fracture with Cannulated Cancellous Screws and Anterior Tension Band Wiring- A Prospective Study

2020 ◽  
Vol 11 (4) ◽  
pp. 7985-7989
Author(s):  
Senthil Loganathan ◽  
Raghavendran B ◽  
Thiyagarajan U ◽  
Pradeep J

Patella fractures accounts for 1% of all skeletal injuries.  Patella fractures usually need to be treated with accurate reduction and fixation to obtain optimal knee function. Improper reduction of the articular fragments leads to complications like arthritis and quadriceps dysfunction. Tension band wiring and pasting are commonly performed fixation methods. Tension band wiring with K-wires is associated with wire prominence and soft tissue irritation. Cannulated cancellous screw fixation of the fracture and tension band wiring through the cannulated screws avoid the complication of wire migration and breakage.   In our study, we fixed these fractures with cannulated cancellous screws and tension band. This is a prospective study done in SRMC from 2012-2017. A total of 17 Patients with transverse patella fracture are taken into a study, 4mm cannulated cancellous screws with 18 mm stainless steel wire is used for anterior tension band wiring. Extensor retinaculum closure is done for all these patients. All patients had excellent knee function, according to KSS. There was no case of implant prominence or soft issue irritation in any of these patients. One patient had extensor lag. Cannulated cancellous screw with anterior tension band wiring is a reliable, effective and reproducible technique in treating transverse patella fractures.

Author(s):  
Ashutosh Parate ◽  
Vasant Gawande ◽  
Suvarn Gupta ◽  
Ankit Jaiwal ◽  
Ashwin Chavan ◽  
...  

Introduction: Olecranon fracture are some of the common injuries seen in emergency with commonest mode of trauma being fall on outstretched hand and road traffic accident. Methods: This prospective comparative study was carried out from May 2020 to May 2021 within a study period of 1 year in Datta Meghe Medical College. 20 patients of olecranon fractures were enrolled randomly. Results: According to the Mayo classification, the majority of the cases in our study were type II A fractures. The Mayo elbow performance score. In the K wire category, 5 patients (50%) had excellent results, 3 patients (30%) had decent results, and 2 patients (20%) had fair results. In both categories, there were no negative repercussions. In the cancellous screw category, excellent results were found in 8 patients (80%), nice in 1 patient (10%), and fair in 1 patient (10%). Conclusions: From this study, we came to the conclusion that for displaced olecranon fractures as per Mayo’s II A classification fixed by using cancellous screw with tension band wiring gives better clinical outcome When compared to tension band wiring, K-wire fixation keeps costs down, time, and the chance of implant removal complications.


Author(s):  
Santosh Reang ◽  
Pulak Saha ◽  
Tapan K. Das

<p class="abstract">Patella fracture consists of approximately 1% of all skeletal fractures. However bilateral patella fracture is even rarer (2-3% of all patella fractures) and is seen mostly in either dash board injuries or in different pathological conditions. A 21 year old male presented with bilateral patella fracture, where right patella was fractured due to RTA and the left one got fractured due to a fall while he was being helped for an X-ray for the first one. Bilateral tension band wiring was done and patient was being regularly followed up with good range of movement recovery. But again he had a fall in bathroom 3 month post-operative and on right side suffered a re-fracture. Modified tension band wiring was done. Patient gained full range of movement on both sides and returned to his normal activities at 9 months post op of index surgery. A case of bilateral patella fracture where mechanism of fracture for each patella fracture are different is unheard of. A case of bilateral patella fracture with re-fracture has not been reported yet in literature so far we know/ searched. Here we report and discuss the challenges in management of such a case and protocol we followed.</p>


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Puripun Jirangkul ◽  
Arkaphat Kosiyatrakul

Abstract Background Modified tension band fixation has become commonly used for transverse patella fractures. The conventional stainless steel wire provides sufficient stability but may be associated with complications. Objective The study aimed to evaluate the effectiveness of a new modified tension band fixation technique for transverse patella fractures using a nonabsorbable suture. Material and methods We present the result of a prospective series using a nonabsorbable suture (FiberWire) for transverse patella fractures. The mean follow-up period totaled 12 months. A total of 16 patients were evaluated by radiographic and clinical review. The postoperative clinical evaluation employed Lysholm and Böstman scores. Result All clinical results on follow-up were good to excellent. Minimal intra-articular joint stepping and further fracture displacement were recorded. No patient needed re-operation, and functional outcomes of the knee were satisfactory. No significant differences were found between the injured and contralateral knee range of motion. No symptomatic implants and skin complications were noted, and all fractures were completed heal within 15 weeks. Conclusion FiberWire provided sufficient stability and reduced postoperative complications. The results proved appropriate, and the technique has merit, as it obviates the need for re-operation.


Sign in / Sign up

Export Citation Format

Share Document