Improvement of clinical fracture healing – What can be learned from mechano-biological research?

2021 ◽  
Vol 115 ◽  
pp. 110148
Author(s):  
Lutz Claes
Bone ◽  
2009 ◽  
Vol 45 (5) ◽  
pp. 862-869 ◽  
Author(s):  
Sjoerd Rutten ◽  
Peter A. Nolte ◽  
Clara M. Korstjens ◽  
Jenneke Klein-Nulend

Author(s):  
Mircea Fotino

The use of thick specimens (0.5 μm to 5.0 μm or more) is one of the most resourceful applications of high-voltage electron microscopy in biological research. However, the energy loss experienced by the electron beam in the specimen results in chromatic aberration and thus in a deterioration of the effective resolving power. This sets a limit to the maximum usable specimen thickness when investigating structures requiring a certain resolution level.An experimental approach is here described in which the deterioration of the resolving power as a function of specimen thickness is determined. In a manner similar to the Rayleigh criterion in which two image points are considered resolved at the resolution limit when their profiles overlap such that the minimum of one coincides with the maximum of the other, the resolution attainable in thick sections can be measured by the distance from minimum to maximum (or, equivalently, from 10% to 90% maximum) of the broadened profile of a well-defined step-like object placed on the specimen.


Author(s):  
Zhifeng Shao ◽  
Ruoya Ho ◽  
Andrew P. Somlyo

Electron energy loss spectroscopy (EELS) has been a powerful tool for high resolution studies of elemental distribution, as well as electronic structure, in thin samples. Its foundation for biological research has been laid out nearly two decades ago, and in the subsequent years it has been subjected to rigorous, but by no means extensive research. In particular, some problems unique to EELS of biological samples, have not been fully resolved. In this article we present a brief summary of recent methodological developments, related to biological applications of EELS, in our laboratory. The main purpose of this work was to maximize the signal to noise ratio (S/N) for trace elemental analysis at a minimum dose, in order to reduce the electron dose and/or time required for the acquisition of high resolution elemental maps of radiation sensitive biological materials.Based on the simple assumption of Poisson distribution of independently scattered electrons, it had been generally assumed that the optimum specimen thickness, at which the S/N is a maximum, must be the total inelastic mean free path of the beam electron in the sample.


Sign in / Sign up

Export Citation Format

Share Document