scholarly journals Radiation Dose in Percutaneous Coronary Intervention

2011 ◽  
Vol 4 (3) ◽  
pp. 344-346 ◽  
Author(s):  
Charles E. Chambers
2018 ◽  
Vol 183 (4) ◽  
pp. 475-482 ◽  
Author(s):  
M Maghbool ◽  
M A Hosseini

Abstract The stochastic and non-stochastic (deterministic) effects of radiation dose in patients undergoing primary percutaneous coronary intervention (PPCI) have been investigated using data recorded by an angiographic monitoring system. A total of 132 patients with acute myocardial infarction referred to the angiography department of Vali-Asr hospital, Fasa, Iran, during the second half of 2016 were recruited. Quantities like dose–area product (DAP), total air kerma (Ka,r) and fluoroscopy time (FT) were calculated and converted into effective dose (ED) and peak skin dose (PSD). The values for Ka,r, DAP and FT equaled 80 399.20 ± 63 312 mGy cm2, 1392.80 ± 1155.373 mGy and 524.11 ± 423.057 s, respectively, which were within the ranges reported in previous studies. After considering standard dose thresholds for Ka,r and PSD, it was revealed that only a small portion of patients had reached these thresholds and exceeded them (<3%). Moreover, ED < 20 mSv for the majority of patients was fairly consistent with results from a recent research in eight Belgian hospitals. It was shown that angiographic records are reliable for assessing radiation dose in patients.


2019 ◽  
Vol 2019 ◽  
pp. 1-5 ◽  
Author(s):  
Kfier Kuba ◽  
Diana Wolfe ◽  
Alan H. Schoenfeld ◽  
Anna E. Bortnick

There is a gap in the literature regarding fetal radiation exposure from interventional cardiac procedures. With an increasingly large and complex cohort of pregnant cardiac patients, it is necessary to evaluate the safety of invasive cardiac procedures and interventions in this population. Here we present a case of a patient with multiple medical comorbidities and non-ST elevation myocardial infarction (NSTEMI) at 15 weeks’ gestation, managed with percutaneous coronary intervention (PCI). We were able to minimize the maternal and estimated fetal absorbed radiation dose to <1 milliGray (mGy), significantly less than the threshold dose for fetal adverse effects at this gestational age.


2006 ◽  
Vol 19 (3) ◽  
pp. 237-244 ◽  
Author(s):  
VIRGINIA TSAPAKI ◽  
ATHANASSIOS MAGGINAS ◽  
ELISEO VANO ◽  
SOPHIA KOTTOU ◽  
EMMANOUIL PAPADAKIS ◽  
...  

2021 ◽  
Vol 10 (21) ◽  
pp. 5002
Author(s):  
Ricardo Rivera-López ◽  
Celia García-López ◽  
José M. Sánchez-Moreno ◽  
Rafael A. Rivera-López ◽  
Julio Almansa-López ◽  
...  

Development of cataracts is a well-known adverse effect of ionizing radiation, but little information is available on their incidence in patients after other medical procedures, such as cardiac catheterizations. The study objective was to determine the incidence of cataracts in a cohort of patients undergoing percutaneous coronary intervention (PCI) for chronic coronary total occlusion (CTO) and its association with radiation dose. The study analyzed the incidence of cataracts during the follow-up of 126 patients who underwent chronic total coronary PCI, using Cox regression to identify predictive factors of cataract development. The study included 126 patients, 86.9% male, with a mean age of 60.5 years (range, 55.0–68.0 years). Twenty-three (18.2% n = 23) developed cataracts during a mean follow-up of 49.5 months (range 37.3–64.5 months). A higher incidence was observed in patients who received more than 5 Gy (29.0% vs. 14.7%, Hazard ratio (HR = 2.84 [1.19–6.77]). Multivariate analysis revealed a relationship between cataract development during the follow-up and a receipt of radiation dose >5 Gy (HR = 2.60, 95% confidence interval [CI 1.03–6.61]; p = 0.03), presence or history of predisposing eye disease (HR = 4.42, CI:1.57–12.40), diabetes (HR = 3.33 [1.22–9.24]), and older age, as in >57 (HR, 6.40 [1.81–22.61]). An elevated incidence of cataracts was observed in patients after PCI for CTO. The onset of cataracts is related to the radiation dose during catheterization, which is a potentially avoidable effect of which operators should be aware.


Author(s):  
David E Winchester ◽  
Randy Jeffrey ◽  
Carsten Schmalfuss ◽  
David C Wymer ◽  
Vicente Taasan ◽  
...  

Introduction: Current guidelines for myocardial perfusion imaging (MPI) encourage facilities to adopt patient-centered risk mitigation strategies such as individualized radiotracer dosing and stress-first imaging. Reducing radiation exposure is also a key recommendation of multiple societies participating in the Choosing Wisely campaign. The stated goal is for over 50% of studies to be performed with <9 millisieverts (mSv) of radiation exposure. We hypothesized that adoption of a stress-first/stress-only imaging protocol would substantially reduce the median radiation dose administered in our nuclear lab. Methods: We switched the standard imaging protocol at the Malcom Randall VA Medical Center nuclear cardiology laboratory from rest-stress to stress-rest. To achieve this, a physician was required to review the stress images at the time they were obtained to determine if further imaging was indicated. Estimated effective radiation doses (in mSv) were calculated based on the radiotracer activity administered (in millicuries) used industry standards techniques. We compared 2 cohorts of patients: rest-stress studies consecutively done between 7/17/17 and 11/12/17 and stress-first studies consecutively done between 11/13/17 and 5/17/17. As a balancing measure, we compared the rate of normal studies between the cohorts. A normal MPI was defined as no evidence of ischemia or infarction with a preserved ejection fraction. Results: In the stress-first cohort, the median dose was 2.8 millisieverts (mSv) compared with 14.1 mSv in the rest-stress cohort (80.1% reduction, p<0.0001). During the observed period, we estimate that 4,780 mSv of effective dose were avoided. In the rest-stress cohort, 424 studies were performed. In the stress-first cohort, 716 tests were performed, 423 stress only studies (59.1%) and 293 stress-rest studies (40.1%). The rate of normal studies in the stress-first cohort was not different from the rest-stress cohort (stress-first: 73.5%, (526/716) versus rest-stress: 71.7%, p=0.54, odds ratio 0.92, 95% CI 0.69-1.21) In the rest-stress cohort, 3 patients (1.0%) underwent coronary angiography and 2 patients (0.7%) underwent percutaneous coronary intervention (PCI). In the stress-first cohort 8 patients (1.1%) underwent coronary angiography and 2 patient (0.3%) underwent percutaneous coronary intervention (PCI). Conclusion: By switching from a rest-stress to a stress-first imaging protocol, we reduced the median radiation dose in our lab by 80%. We observed no change in the proportion of normal tests, suggesting no potential for harm with this strategy.