Molecularly imprinted colloidal array with multi-boronic acid sites for glycoprotein detection under neutral pH

Author(s):  
Wei Chen ◽  
Zhiyang Guo ◽  
Hao Yu ◽  
Qingyun Liu ◽  
Min Fu
The Analyst ◽  
2019 ◽  
Vol 144 (21) ◽  
pp. 6432-6437 ◽  
Author(s):  
Yanli Zhou ◽  
Huijie Huangfu ◽  
Jie Yang ◽  
Hui Dong ◽  
Lantao liu ◽  
...  

A potentiometric sensor for sialic acid detection was designed based on a boronic acid-containing MIP modified carbon cloth electrode.


2017 ◽  
Vol 423 ◽  
pp. 810-816 ◽  
Author(s):  
Xi Zhou ◽  
Xuexia Gao ◽  
Fengyan Song ◽  
Chunpeng Wang ◽  
Fuxiang Chu ◽  
...  

2017 ◽  
Vol 960 ◽  
pp. 110-116 ◽  
Author(s):  
Jing-ru Wei ◽  
Yan-li Ni ◽  
Wei Zhang ◽  
Zhi-qi Zhang ◽  
Jing Zhang

2019 ◽  
Vol 44 (6) ◽  
pp. 738-744 ◽  
Author(s):  
Zihni Onur Uygun ◽  
Burcu Okutucu ◽  
Şükriye Hacikara ◽  
Ferhan Sağın

Abstract Background In this study, we synthesized molecularly imprinted copolymers for liquid chromatography columns as a separator for glycosaminoglycan (dermatan sulfate; DS and chondroitin sulfate; CS) in urine. Materials and methods Acrylamide and acrylamido phenylboronic acid were used as monomers, acrylamide was used for as base monomer to attract negatively charged groups and acrylamido phenylboronic acid (AAPBA) residues used to form diol bonds between sugar and boronic acid residues to strengthen the attraction. These monomers were synthesized by using precipitation polymerization to form uniform spheres, which are more durable for the pressurized chromatographic systems. Trimethylolpropane trimethacrylate and AIBN were used as crosslinker and starter, respectively. Results These GAG selective polymers were filled by pressurized flow into the steel (4.6 mm × 1.6 mm) columns, then imprinted GAGs were extracted and analyzed to calculate binding capacity of each milligram polymer. Calibration curves of the GAG selective columns were obtained 62.5–1000 ng/mL less than 5% coefficient variation, and lower matrix effect. Conclusion Our imprinted columns separated different GAGs from urine specifically and sensitively. Matrix effect was at an ignorable level thus the challenging use.


2017 ◽  
Vol 53 (53) ◽  
pp. 7290-7293 ◽  
Author(s):  
Takuya Kubo ◽  
Hayato Furuta ◽  
Toyohiro Naito ◽  
Tomoharu Sano ◽  
Koji Otsuka

Molecularly imprinted PEG-based hydrogels were prepared for carbohydrates and glycoproteins. Visible detection of fructose was achieved by the gels.


2014 ◽  
Vol 2 (6) ◽  
pp. 637-643 ◽  
Author(s):  
Zian Lin ◽  
Lixiang Sun ◽  
Wei Liu ◽  
Zhiwei Xia ◽  
Huanghao Yang ◽  
...  

2004 ◽  
Vol 14 (1) ◽  
pp. 25-27 ◽  
Author(s):  
Hormuzd R. Mulla ◽  
Nicholas J. Agard ◽  
Amit Basu

Sign in / Sign up

Export Citation Format

Share Document