A validation study of a continuous automatic measurement of the mechanical power in ARDS patients

2022 ◽  
Vol 67 ◽  
pp. 21-25
Author(s):  
D. Chiumello ◽  
S. Coppola ◽  
P. Formenti ◽  
A. Ciabattoni ◽  
M. Lucenteforte ◽  
...  
2020 ◽  
Vol 56 ◽  
pp. 167-170
Author(s):  
Sinan Aşar ◽  
Özlem Acicbe ◽  
Zafer Çukurova ◽  
G. Oya Hergünsel ◽  
Emral Canan ◽  
...  

Author(s):  
J. C. Russ ◽  
T. Taguchi ◽  
P. M. Peters ◽  
E. Chatfield ◽  
J. C. Russ ◽  
...  

Conventional SAD patterns as obtained in the TEM present difficulties for identification of materials such as asbestiform minerals, although diffraction data is considered to be an important method for making this purpose. The preferred orientation of the fibers and the spotty patterns that are obtained do not readily lend themselves to measurement of the integrated intensity values for each d-spacing, and even the d-spacings may be hard to determine precisely because the true center location for the broken rings requires estimation. We have implemented an automatic method for diffraction pattern measurement to overcome these problems. It automatically locates the center of patterns with high precision, measures the radius of each ring of spots in the pattern, and integrates the density of spots in that ring. The resulting spectrum of intensity vs. radius is then used just as a conventional X-ray diffractometer scan would be, to locate peaks and produce a list of d,I values suitable for search/match comparison to known or expected phases.


2004 ◽  
Vol 171 (4S) ◽  
pp. 416-416
Author(s):  
Shai Sheji ◽  
Ruth Weissenberg ◽  
Gil Raviv ◽  
Igael Madgar

1999 ◽  
Vol 41 (2) ◽  
pp. 110-114 ◽  
Author(s):  
Svend Erik Mouridsen ◽  
Bente Rich ◽  
Torben Isager

VASA ◽  
2005 ◽  
Vol 34 (4) ◽  
pp. 255-261 ◽  
Author(s):  
Diehm ◽  
Baumgartner ◽  
Silvestro ◽  
Herrmann ◽  
Triller ◽  
...  

Background: Open surgical or endovascular abdominal aortic aneurysm (AAA) relies on precise preprocedual imaging. Purpose of this study was to assess inter- and intraobserver variation of software-supported automated and manual multi row detector CT angiography (MDCTA) in aortoiliac diameter measurements before AAA repair. Patients and methods: Thirty original MDCTA data sets (4 times 2mm collimation) of patients scheduled for endovascular AAA repair were studied on a dedicated software capable of creating two-dimensional reformatted planes orthogonal to the aortoiliac center-line. Measurements were performed twice with a four-week interval between readings. Data were analysed by two blinded readers at random order. Two different measurement methods were performed: reader-assisted freehand wall-to-wall measurement and semi-automatic measurement. Results: Aortoiliac diameters were significantly underestimated by the semi-automatic method as compared to reader-assisted measurements (p < 0.0031). Intraobserver variability of AAA diameter calculation was not significant (p > 0.15) for reader-assisted measurements except for the diameter of the left common iliac artery in reader 2 (p = 0.0045) and it was not significant (p > 0.14) using the semi-automatic method. Interobserver variability was not significant for AAA diameter measurements using the reader-assisted method and for proximal neck analysis with the semi-automatic method (p > 0.27). Relevant interobserver variation was observed for semi-automatic measurement of maximum AAA (p = 0.0007) and iliac artery diameters (p = 0.024). Conclusions: Dedicated MDCTA software provides a useful tool to minimize aortoiliac diameter measurement variation and to improve imaging precision before AAA repair. For reliable AAA diameter analysis the reader-assisted freehand measurement method is recommended to be applied to a set of reformatted CT data as provided by the software used in this study.


Sign in / Sign up

Export Citation Format

Share Document