Blue-light filtering intraocular lens in patients with diabetes: Contrast sensitivity and chromatic discrimination

2005 ◽  
Vol 31 (11) ◽  
pp. 2088-2092 ◽  
Author(s):  
Antonio Rodríguez-Galietero ◽  
Robert Montés-Micó ◽  
Gonzalo Muñoz ◽  
Cesar Albarrán-Diego
2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Ahmed A. Zein El-Dein ◽  
Ahmed Elmassry ◽  
Hazem M. El-Hennawi ◽  
Ehab F. Mossallam

Abstract Background This study aimed to assess visual outcomes, quality of vision and patients’ satisfaction of a trifocal diffractive intraocular lens after cataract surgery with phacoemulsification. Results The study included 36 eyes that underwent implantation of trifocal diffractive intraocular lens (IOL). The residual mean postoperative spherical equivalent was − 0.40 ± 0.29 diopters. Mean Uncorrected distance visual acuity was 0.80 ± 0.16 decimal (snellen equivalent 25 ft) while mean Uncorrected intermediate visual acuity was 0.82 ± 0.31 decimal (snellen equivalent 25 ft) and mean Uncorrected near visual acuity (UCNVA) was 0.87 ± 0.20 decimal (snellen equivalent 23 ft). In defocus curve, there was infinitesimal gradual change between the three foci. Contrast sensitivity was just below the inferior limit of normal. Conclusion Trifocal diffractive IOL created a true intermediate focus proved by VA and defocus curve and better quality of vision assessed by contrast sensitivity and high order aberration. Moreover, it was safe and effective for correcting distance and near vision in these patients. Most of the patients were very satisfied and achieved spectacle independence. Trial registration Registration number and date: NCT04465279 on July 10, 2020.


2016 ◽  
Vol 36 (6) ◽  
pp. 829-839
Author(s):  
Kumiko Mokuno ◽  
Tetsu Asami ◽  
Norie Nonobe ◽  
Hirotaka Ito ◽  
Kumi Fujiwara ◽  
...  

2010 ◽  
Vol 149 (3) ◽  
pp. 383-389.e2 ◽  
Author(s):  
Marcony R. Santhiago ◽  
Marcelo V. Netto ◽  
Jackson Barreto ◽  
Beatriz A.F. Gomes ◽  
Adriana Mukai ◽  
...  

2017 ◽  
Vol 6 (2) ◽  
pp. 301-312 ◽  
Author(s):  
Marcelo Fernandes da Costa ◽  
Augusto Paranhos Júnior ◽  
Claudio Luiz Lottenberg ◽  
Leonardo Cunha Castro ◽  
Dora Fix Ventura

2018 ◽  
Vol 28 (4) ◽  
pp. 419-424 ◽  
Author(s):  
Jorge L Alió ◽  
Ana B Plaza-Puche ◽  
Jorge L Alió del Barrio ◽  
Pedro Amat-Peral ◽  
Vicente Ortuño ◽  
...  

Purpose: To evaluate clinical and visual outcomes, quality of near vision, and intraocular optical quality of patients bilaterally implanted with a trifocal PanOptix intraocular lens. Methods: In this prospective consecutive case-series study, 52 eyes of 26 bilateral patients (mean age, 60.2 ± 7.4 years) were implanted with the AcrySof IQ Panoptix intraocular lens. Visual acuity, defocus curve, contrast sensitivity (Pelli-Robson test), near activity visual questionnaire, and internal aberrations with Osiris were evaluated. A prototype light-distortion analyzer was used to quantify the postoperative light-distortion indices. The follow-up was 6 months after surgery. Results: Uncorrected, corrected distance, and uncorrected near visual acuities improved with the surgery (p ≤ 0.02). Distance corrected near visual acuity was 0.13 ± 0.10, 0.13 ± 0.13, and 0.13 ± 0.08 at 1, 3, and 6 months after surgery, respectively (p = 0.82). Distance corrected intermediate visual acuities were 0.09 ± 0.13, 0.13 ± 0.15, and 0.12 ± 0.12 at 1, 3, and 6 months, postoperatively. Binocular contrast sensitivity was 1.86 ± 0.15 Log Units. Defocus curve provided a visual acuity equal or better to 0.30 LogMAR between defocus levels of +0.50 to −3.00 D. The near activity visual questionnaire scores improved significantly with the surgery (p < 0.01). Conclusion: The AcrySof IQ Panoptix intraocular lens is able to restore visual function with an acceptable intermediate and near vision after cataract surgery with good contrast sensitivity and an improvement in the near activity visual questionnaire.


2020 ◽  
Vol 36 (7) ◽  
Author(s):  
Huifang Lian ◽  
Weisong Ma ◽  
Qiuhong Wei ◽  
Xiaoyong Yuan

Objectives: To compare early subjective and objective vision quality of postoperative patients undergoing phacoemulsification cataract surgery combined with implantation of refractive segmental multifocal intraocular lens (MIOL) SBL-3 and apodized diffractive MIOL SN6AD1. Methods: As a prospective study, it enrolled 53 patients (53 eyes) to undergo phacoemulsification cataract surgery combined with MIOL implantation. According to differences in MIOL implanted, patients were divided into a SBL-3 group (25 eyes) and a SN6AD1 group (28 eyes). Ophthalmological evaluation included uncorrected (UDVA) and corrected (CDVA) distance visual acuities, uncorrected intermediate (UIVA) and near (UNVA) visual acuities, distance-corrected intermediate (DCIVA) and near (DCNVA)visual acuities and corrected near(CNVA) visual acuity, contrast sensitivity, modulation transfer function (MTF) and high order aberration (4 mm pupil diameter) at three months postoperatively. Moreover, a questionnaire survey was carried out to assess near spectacle independence, patient satisfaction and symptoms of visual disturbance. Results: At three months after surgery, UIVA and UNVA in the SBL-3 group are statistically significantly superior to those of the SN6AD1 group (P<0.05). There was statistical difference in contrast sensitivity at four spatial frequencies (3, 6, 12, 18cycles/degree) under mesopic conditions and mesopic conditions with glare (P<0.05). The total ocular high order aberration, coma and trefoil were statistically significantly larger in the SBL-3 group than in the SN6AD1 group with 4.0 mm pupil diameters (P<0.05). Statistical differences were found in the MTF at spatial frequencies of 5, 10 and 15 cycles/degree between the groups. There were no significant differences in spectacle independence, patient satisfaction and visual disturbance between the groups (P>0.05). Conclusions: Both the two multifocal intraocular lens provided an excellent level of quality of vision three months postoperatively. However, the application effect of SBL-3 MIOL is superior to that of SN6AD1 MIOL as far as intermediate vision, near vision and contrast sensitivity are concerned. doi: https://doi.org/10.12669/pjms.36.7.3364 How to cite this:Lian H, Ma W, Wei Q, Yuan X. A comparative study on early vision quality after implantation of refractive segmental and diffractive multifocal intraocular lens. Pak J Med Sci. 2020;36(7):---------. doi: https://doi.org/10.12669/pjms.36.7.3364 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.


Sign in / Sign up

Export Citation Format

Share Document