defocus curve
Recently Published Documents


TOTAL DOCUMENTS

36
(FIVE YEARS 25)

H-INDEX

5
(FIVE YEARS 2)

2021 ◽  
Vol 2021 ◽  
pp. 1-8
Author(s):  
Francisco Poyales ◽  
Ricardo Pérez ◽  
Israel López-Brea ◽  
Ying Zhou ◽  
Nuria Garzón

Purpose. To compare postcataract surgery visual and optical performance between two trifocal intraocular lenses (IOLs) with the same optical design: a hydrophobic acrylic glistening-free IOL and a hydrophilic acrylic IOL. Methods. Patients were bilaterally implanted with either the hydrophobic or the hydrophilic IOL. The data of the patients’ right eyes were evaluated. Visual quality assessments included refractive outcomes, monocular visual acuity (VA) at far, intermediate, and near distances, defocus curve, aberrations (spherical aberration (SA)), root mean square (RMS) of corneal, internal, and total higher-order aberrations (HOAs)), and tilt of IOL. Results. Fifty-one patients were included in the analysis: 26 patients implanted with the hydrophobic IOL and 25 patients implanted with the hydrophilic IOL. At 1 month, no statistically significant differences were found for monocular uncorrected and corrected VA at distance, distance-corrected VA at intermediate and near, defocus curve, manifest spherical equivalent, total SA, and RMS of the total, internal, and corneal HOA. The defocus curve of both groups showed a visual acuity of 0.3 logMAR or better in the intermediate range from 0.5 to −2.5 D of vergence level with no significant differences between the groups. Compared to the hydrophilic group, y-direction tilt was significantly higher in the hydrophobic group ( p = 0.027 ). The total tilt and x-axis tilt did not differ between the groups. Conclusion. Both IOLs demonstrated an excellent quality of vision and provided the patient with a wide range of vision.


2021 ◽  
pp. 112067212110676
Author(s):  
Cem Ozturkmen ◽  
Cem Kesim ◽  
Pinar Gunel Karadeniz ◽  
Afsun Sahin

Purpose To compare visual acuity, defocus curve and visual quality of life performances of a new hybrid refractive-diffractive intraocular lens (IOL) and a trifocal diffractive IOL. Methods Patients who underwent cataract surgery with bilateral implantation of ZFR00V or TFNT00 IOLs were enrolled in this study. The main outcomes were defined as uncorrected distant, intermediate and near visual acuities (UDVA, UIVA and UNVA, respectively), defocus curve and VF-14 questionnaire aimed for visual performance. Results Fifty patients, of whom 30 had bilateral ZFR00V implantation, were enrolled in the study. Patients with ZFR00V had significantly better UIVA than patients with TFNT00 (0.05 ± 0.03 vs. 0.07 ± 0.04 logMAR, P = 0.02). Defocus curve showed significantly higher visual acuity in intermediate range for ZFR00V IOL between −1.00 and −1.50 dioptres (all P < 0.05). All patients had good visual performance with mean VF-14 scores above 3 points with no significant difference between two IOL models. Spectacle independence was 100% for both distant and near vision in both group of patients. Conclusion Bilateral implantation of ZFR00V in cataract patients shows better intermediate visual acuity scores and similar daily visual performance when compared with trifocal TFNT00 IOL.


2021 ◽  
Author(s):  
Karolina Podboraczynska-Jodko ◽  
Wojciech Lubiński

Abstract PurposeTo study visual outcomes after implantation of Versario intraocular lenses (IOLs) Patients and MethodsIn 20 selected patients (40 eyes) uneventful, bilateral cataract surgeries with implantation of trifocal Versario (IOLs) were performed. Designprospective case series. Six months after surgery the following parameters were analysed: binocular uncorrected visual acuities (log MAR): for distance (UDVA) at 4 m, for intermediate (UIVA) at 60, 70, 80 cm and for near (UNVA) at 40 cm, photopic defocus curve, mesopic and photopic contrast sensitivities (CSs), spectacle independence, visual function test questionnaire (modified VFQ-25), subjective symptoms and postoperative complications. ResultsSix months after surgery, the mean of binocular visual acuities were as follows: UDVA: -0.12 ± 0.08; UIVA (60 cm): +0.07 ± 0.10, (70 cm): +0.05 ± 0.11, (80cm): +0.07 ± 0.09; UNVA (40cm): +0.12 ± 0.08. CSs in mesopic and scotopic conditions for distance and photopic for near were between normal range of age- match healthy control. All patients were spectacle independent. General satisfaction was high and equal 9.37±0.83. No severe glare and halo were detected. There were no postoperative complications. ConclusionsThe bimanual MICS with the Versario lenses implantation was a safe and effective method for patients who want to be spectacle independent at different distances.


2021 ◽  
pp. 112067212110573
Author(s):  
Cem Ozturkmen ◽  
Cem Kesim ◽  
Pinar Gunel Karadeniz ◽  
Afsun Sahin

Purpose: To evaluate the visual acuity, defocus curve and visual quality of life following bilateral implantation of a new hybrid extended depth of focus (EDOF)-multifocal diffractive intraocular lens (IOL). Methods: Patients who underwent cataract surgery with bilateral implantation of Tecnis Synergy IOL were enrolled in this study. The main outcomes were defined as uncorrected distant, intermediate and near visual acuities (UDVA, UIVA and UNVA, respectively), defocus curve and VF-14 questionnaire aimed for visual performance. Results: The mean ± SD values for binocular UDVA, UIVA and UNVA were −0.01 ± 0.04, 0.05 ± 0.03 and 0.03 ± 0.05 logMAR, respectively. Defocus curve showed a continuous vision above 0.16 logMAR between +0.50 D and −2.50 D. Patients had good visual performance with mean VF-14 scores above 3 points. Driving at night (3.47 ± 0.64) was found to be the most difficult task to perform. Spectacle independence was 100% for both distant and near vision. Conclusion: Bilateral implantation of Tecnis Synergy IOL in cataract patients shows good visual acuity and performance, covering a good visual range without any need of spectacles.


2021 ◽  
Vol 2021 ◽  
pp. 1-9
Author(s):  
Ji Eun Song ◽  
So Young Han ◽  
Ramin Khoramnia ◽  
Tamer Tandogan ◽  
Gerd U. Auffarth ◽  
...  

Purpose. To evaluate monocular and binocular visual performance and patient-reported outcomes following combined implantation of a diffractive extended depth of focus (EDoF) IOL (Carl Zeiss AT LARA 829MP) and a diffractive trifocal IOL (Carl Zeiss AT LISA tri 839MP). Methods. This prospective study enrolled consecutive patients undergoing lens phacoemulsification of cataract and combined implantation of an EDoF IOL in the dominant eye and a trifocal IOL in the nondominant eye. Assessment included uncorrected visual acuity at near distances (UNVA), intermediate distances (UIVA), and far distances (UDVA), uncorrected defocus curve, contrast sensitivity (CS), reading speed, and patient satisfaction, evaluated six months after the surgery with the Visual Function Questionnaire (VFQ-25). Results. A total of 25 patients were enrolled. At six months postoperatively, outcomes of binocular UNVA, UIVA, and UDVA were superior to those of monocular outcomes. The binocular defocus curve showed significantly better results in comparison with the AT LISA tri IOL eyes at defocus levels of −1.0 D and −1.5 D ( P = 0.008 and P = 0.002 , respectively) and compared to the AT LARA IOL eyes at defocus levels of −3.0, −3.5 D, and −4.0 D ( P = 0.019 , P = 0.019 , and P = 0.035 , respectively). All of the patients were spectacle-free at far and intermediate distances, while 4% of patients needed spectacles at the near distance. Reading speed showed a rather high and gentle slope curve between 0.1 logMAR and 0.4 logMAR, and optical phenomena were improved after combined implantation of IOLs except halos. There were no significant differences in CS between the binocular and monocular results of each IOL. Conclusions. The combined implantation of an EDoF IOL and a trifocal IOL seems to be a good option for patients with demands for spectacle independence in their daily life, with minimal photic phenomena.


2021 ◽  
Vol 10 (9) ◽  
pp. 2009
Author(s):  
Joaquín Fernández ◽  
Manuel Rodríguez-Vallejo ◽  
Javier Martinez ◽  
Noemi Burguera ◽  
David P. Piñero

(1) Background: To evaluate the efficacy at 6 years postoperative after the implantation of a trifocal intraocular lens (IOL) AT Lisa Tri 839MP. The secondary objective was to evaluate the contrast sensitivity defocus curve (CSDC), light distortion analysis (LDA), and patient reported outcomes (PROs). (2) Methods: Sixty-two subjects participated in phone call interviews to collect data regarding a visual function questionnaire (VF-14), a patient reported spectacle independence questionnaire (PRSIQ), and questions related to satisfaction and decision to be implanted with the same IOL. Thirty-seven of these subjects were consecutively invited to a study visit for measurement of their visual acuity (VA), CSDC, and LDA. (3) Results: The mean monocular distance corrected VA was −0.05, 0.08, and 0.05 logMAR at far and distances of 67 cm and 40 cm, respectively. These VAs were significantly superior to those reported in previous literature (p < 0.05). The total area under the CSDC was 2.29 logCS/m−1 and the light distortion index 18.82%. The mean VF-14 score was 94.73, with 19.4% of subjects requiring spectacles occasionally for near distances, and 88.9% considering the decision of being operated again; (4) Conclusions: Long-term AT LISA Tri 839MP IOL efficacy results were equal or better than those reported 12 months postoperatively in previous studies. The spectacle independence and satisfaction rates were comparable to those reported in short-term studies.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Ahmed A. Zein El-Dein ◽  
Ahmed Elmassry ◽  
Hazem M. El-Hennawi ◽  
Ehab F. Mossallam

Abstract Background This study aimed to assess visual outcomes, quality of vision and patients’ satisfaction of a trifocal diffractive intraocular lens after cataract surgery with phacoemulsification. Results The study included 36 eyes that underwent implantation of trifocal diffractive intraocular lens (IOL). The residual mean postoperative spherical equivalent was − 0.40 ± 0.29 diopters. Mean Uncorrected distance visual acuity was 0.80 ± 0.16 decimal (snellen equivalent 25 ft) while mean Uncorrected intermediate visual acuity was 0.82 ± 0.31 decimal (snellen equivalent 25 ft) and mean Uncorrected near visual acuity (UCNVA) was 0.87 ± 0.20 decimal (snellen equivalent 23 ft). In defocus curve, there was infinitesimal gradual change between the three foci. Contrast sensitivity was just below the inferior limit of normal. Conclusion Trifocal diffractive IOL created a true intermediate focus proved by VA and defocus curve and better quality of vision assessed by contrast sensitivity and high order aberration. Moreover, it was safe and effective for correcting distance and near vision in these patients. Most of the patients were very satisfied and achieved spectacle independence. Trial registration Registration number and date: NCT04465279 on July 10, 2020.


2021 ◽  
Author(s):  
Ahmed A. Zein El-Dein ◽  
Ahmed Elmassry ◽  
Hazem M. El Hennawi ◽  
Ehab F. Mossallam

Abstract Background: This study aimed to assess visual outcomes, quality of vision and patients’ satisfaction of a trifocal diffractive intraocular lens after cataract surgery with phacoemulsification.Results: The study included 36 eyes that underwent implantation of trifocal diffractive intraocular lens (IOL). The residual mean postoperative spherical equivalent was –0.40 ± 0.29 diopters. Mean Uncorrected distance visual acuity was 0.80 ± 0.16 decimal (snellen equivalent 25 feet) while mean Uncorrected intermediate visual acuity was 0.82 ± 0.31 decimal (snellen equivalent 25 feet) and mean Uncorrected near visual acuity (UCNVA)was 0.87 ± 0.20 decimal (snellen equivalent 23 feet). In defocus curve, there was infinitesimal gradual change between the three foci. Contrast sensitivity was just below the inferior limit of normal. Conclusion: Trifocal diffractive IOL created a true intermediate focus proved by VA and defocus curve and better quality of vision assessed by contrast sensitivity and high order aberration. Moreover, it was safe and effective for correcting distance and near vision in these patients. Most of the patients were very satisfied and achieved spectacle independence.


2021 ◽  
Vol 69 (5) ◽  
pp. 1348
Author(s):  
Sonam Yangzes ◽  
Neha Kamble ◽  
Sartaj Grewal ◽  
SatinderPal Singh Grewal

Sign in / Sign up

Export Citation Format

Share Document