Rotational stability of a toric intraocular lens: Influence of axial length and alignment in the capsular bag

2012 ◽  
Vol 38 (1) ◽  
pp. 54-59 ◽  
Author(s):  
Gauri D. Shah ◽  
Mamidipudi R. Praveen ◽  
Abhay R. Vasavada ◽  
Viraj A. Vasavada ◽  
Gauri Rampal ◽  
...  
2014 ◽  
Vol 40 (9) ◽  
pp. 1479-1487 ◽  
Author(s):  
Rita Mencucci ◽  
Eleonora Favuzza ◽  
Francesca Guerra ◽  
Giovanni Giacomelli ◽  
Ugo Menchini

2016 ◽  
Vol 32 (7) ◽  
pp. 444-450 ◽  
Author(s):  
Eduardo F. Marques ◽  
Tiago B. Ferreira ◽  
Pedro Simões

2020 ◽  
Vol 36 (3) ◽  
pp. 186-192 ◽  
Author(s):  
Magdaléna Vokrojová ◽  
Lenka Havlíčková ◽  
Markéta Brožková ◽  
Zuzana Hlinomazová

2020 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Koh Sasaki ◽  
Shuichiro Eguchi ◽  
Akira Miyata ◽  
Tomohisa Nishimura ◽  
Kazunori Miyata ◽  
...  

2020 ◽  
Vol Volume 14 ◽  
pp. 2405-2410
Author(s):  
Helga P Sandoval ◽  
Stephen Lane ◽  
Stephen Slade ◽  
Eric D Donnenfeld ◽  
Richard Potvin ◽  
...  

2020 ◽  
Author(s):  
Zhe Zhang ◽  
Hui Li ◽  
Jing Zhou ◽  
Yaqin Zhang ◽  
Suhua Zhang

Abstract Background: There was no standard technique for measuring corneal astigmatism. The iTrace wavefront aberrometry of cornea calculated steep power and axis based on the best Zernike mathematical fit from all topo data within 4 mm circle. It was supposed to be more accurate than iTrace simulated keratometry which was calculated based on only 4 points on the circle of 3 mm. This study evaluated visual outcomes, rotational stability after performing toric intraocular lens (IOL) implantation planning based on the wavefront aberrometry of the cornea with iTrace. Setting: Single site in China, Shanxi Eye Hospital, Shanxi, China.Design: Prospective case series.Methods: The study included 85 eyes of 63 patients undergoing phacoemulsification and toric IOL implantation. The IOL power and cylinders were chosen with the help of the iTrace toric planning program using wavefront keratometric astigmatism. Over a 3-month follow-up period, astigmatic changes were assessed using the Alpins vector method. Results: Preoperative mean corneal topographic astigmatism was 1.91 diopters (D) ± 0.69 (standard deviation). Postoperative mean refractive astigmatism decreased significantly to 0.48 D ± 0.34. Surgical induced astigmatism was 1.73 D ± 0.77 and the mean correction index was 0.89 ± 0.22, showing a slight undercorrection. The proportion of astigmatism ≤ 0.50 D increased from 0 to 71.8% postoperatively.Conclusions: This is the first study evaluating the clinical outcomes of using iTrace wavefront keratometric readings to plan a toric IOL implantation. The findings show that the iTrace built-in toric calculator with wavefront keratometric astigmatism for toric IOL planning is safe and effective.Trial registration: Current Controlled Trials ISRCTN94956424, Retrospectively registered (Date of registration: 05 February 2020). http://www.isrctn.com/ISRCTN94956424.


2022 ◽  
Vol 22 (1) ◽  
Author(s):  
Iichiro Sugita ◽  
Tomoichiro Ogawa ◽  
Kazuo Ichikawa ◽  
Takahide Okita ◽  
Kazuno Negishi ◽  
...  

Abstract Background To evaluate the safety and efficacy of a new toric intraocular lens (IOL) with anchor-wing haptics. Methods The new toric IOL with anchor-wing haptics (NS60YT, NIDEK Co., Ltd.) was implanted in eligible patients with age-related cataracts with preoperative corneal astigmatism of 1.0 D or greater at a university hospital and two private hospitals in Japan. The following IOL cylinder powers were evaluated: 1.50 D (NS60YT3), 2.25 D (NS60YT4), 3.00 D (NS60YT5) and 4.50 D (NS60YT7). All patients were assessed out to 12 months postoperatively. The primary endpoint was visual acuity (VA) with spherical addition at 6 months postoperatively, and the primary analysis calculated the proportion of eyes with VA with spherical addition of 0.1 logMAR or better. The magnitude of rotation was compared to the intended axis of IOL implantation at each postoperative examination. Adverse events were evaluated for the safety analysis. Results This study enrolled 64 eyes of 53 patients. At 6 months postoperatively, for all IOL powers, VA with spherical addition of 0.1 logMAR or better was achieved in 90% [95% confidence interval (CI): 80–96] of eyes. The mean IOL rotation was 5.3 ± 4.3° at 12 months postoperatively. The mean magnitude of rotation ranged from 1.9° to 2.5° between each postoperative examination from 1 day to 12 months. There were no vision-threatening intraoperative or postoperative complications for the duration of the study. Conclusions The NS60YT IOL remained stable after implantation and was efficacious for treating 1.00 D or greater astigmatism in patients with senile cataracts. Trial registration This study was registered at ClinicalTrials.gov (NCT03242486) on August 8, 2017 - Retrospectively registered.


2020 ◽  
Author(s):  
Zhe Zhang ◽  
Hui Li ◽  
Jing Zhou ◽  
Yaqin Zhang ◽  
Suhua Zhang

Abstract Background: There was no standard technique for measuring corneal astigmatism. The iTrace wavefront aberrometry of cornea calculated steep power and axis based on the best Zernike mathematical fit from all topo data within 4 mm circle. It was supposed to be more accurate than iTrace simulated keratometry which was calculated based on only 4 points on the circle of 3 mm. This study evaluated visual outcomes, rotational stability after performing toric intraocular lens (IOL) implantation planning based on the wavefront aberrometry of the cornea with iTrace. Setting: Single site in China, Shanxi Eye Hospital, Shanxi, China. Design: Prospective case series. Methods : The study included 85 eyes of 63 patients undergoing phacoemulsification and toric IOL implantation. The IOL power and cylinders were chosen with the help of the iTrace toric planning program using wavefront keratometric astigmatism. Over a 3-month follow-up period, astigmatic changes were assessed using the Alpins vector method. Results : Preoperative mean corneal topographic astigmatism was 1.91 diopters (D) ± 0.69 (standard deviation). Postoperative mean refractive astigmatism decreased significantly to 0.48 D ± 0.34. Surgical induced astigmatism was 1.73 D ± 0.77 and the mean correction index was 0.89 ± 0.22, showing a slight undercorrection. The proportion of astigmatism ≤ 0.50 D increased from 0 to 71.8% postoperatively. Conclusions : This is the first study evaluating the clinical outcomes of using iTrace wavefront keratometric readings to plan a toric IOL implantation. The findings show that the iTrace built-in toric calculator with wavefront keratometric astigmatism for toric IOL planning is safe and effective.


2021 ◽  
pp. 112067212110464
Author(s):  
Oya Donmez ◽  
Bilgehan Sezgin Asena ◽  
Yonca Aydin Akova

Purpose: To evaluate the clinical outcomes and quality of life following implantation of PanOptix toric intraocular lens (IOL) and to compare the outcomes following femtosecond laser assisted cataract surgery (FLACS) and standard cataract surgery (SCS). Methods: This comparative retrospective study included 79 eyes of 55 patients underwent cataract or refractive lens exchange surgery between April 2017 and January 2020 in Bayindir Hospital and Kaskaloglu Eye Hospital. Corneal (CA) and refractive astigmatism (RA), uncorrected visual acuities for distant, intermediate, and near (UDVA, UIVA, and UNVA), low contrast distance visual acuity, rotational stability, defocus curves, photopic and mesopic contrast sensitivity (CS), visual function-14 (VF-14) test, presence of dysphotopsia, and need for spectacles were evaluated at postoperative third month. Outcomes were compared between FLACS and SCS group. Results: The mean UDVA, UIVA, and UNVA were 0.05 ± 0.07, 0.08 ± 0.08, and 0.06 ± 0.07 logMAR, respectively. All patients achieved ⩾0.3 logMAR uncorrected visual acuity for all distances. UDVA was found significantly better in FLACS group ( p = 0.03). All eyes had ⩽1 D of subjective postoperative RA. Defocus curve had two peaks at 0 and −1.50 D. Spectacle independence was achieved in 88.7% of patients. Photopic and mesopic CS was within normal range in all patients. The mean VF-14 score was 98 ± 2. The mean IOL axis rotation was 2.1° ± 2.3°. Only one patient reported seeing disturbing halos. Conclusions: This trifocal toric IOL effectively reduced refractive astigmatism and provided excellent visual outcomes with high spectacle independence, patients’ satisfaction, and good rotational stability. FLACS might have an impact on optimal postoperative results.