2193 To Review Informed Patient Decisions Regarding Morcellation of Fibroids Since the FDA Guidance Statement of November 2014.Michael L Moore M.D., Advanced Womens Health Institute, Denver, CO

2019 ◽  
Vol 26 (7) ◽  
pp. S115
Author(s):  
ML Moore
2011 ◽  
Vol 42 (10) ◽  
pp. 1-10
Author(s):  
ELIZABETH MECHCATIE
Keyword(s):  

2006 ◽  
Vol 36 (8) ◽  
pp. 86
Author(s):  
MARY ELLEN SCHNEIDER

2019 ◽  
Vol 1 (1) ◽  
pp. 31
Author(s):  
Fernando Ledesma Perez ◽  
Maria Caycho Avalos ◽  
Juana Cruz Montero ◽  
Andrea Ayala Sandoval

Citizenship is the exercise of the fundamental rights of people in spaces of participation, opinion and commitments, which can not be violated by any health condition in which the individual is. This research aims to interpret the process of construction of citizenship in hospitalized children, was developed through the qualitative approach, ethnomethodological method, synchronous design, with a sample of three students hospitalized in a health institute specializing in childhood, was used Observation technique and a semi-structured interview guide were obtained as results that hospitalized children carry out their citizenship construction in an incipient way, through the communication interaction they make with other people in the environment where they grow up.


Molecules ◽  
2021 ◽  
Vol 26 (13) ◽  
pp. 3789
Author(s):  
Mohammad Hailat ◽  
Israa Al-Ani ◽  
Mohammed Hamad ◽  
Zainab Zakareia ◽  
Wael Abu Dayyih

In the current work, a simple, economical, accurate, and precise HPLC method with UV detection was developed to quantify Favipiravir (FVIR) in spiked human plasma using acyclovir (ACVR) as an internal standard in the COVID-19 pandemic time. Both FVIR and ACVR were well separated and resolved on the C18 column using the mobile phase blend of methanol:acetonitrile:20 mM phosphate buffer (pH 3.1) in an isocratic mode flow rate of 1 mL/min with a proportion of 30:10:60 %, v/v/v. The detector wavelength was set at 242 nm. Maximum recovery of FVIR and ACVR from plasma was obtained with dichloromethane (DCM) as extracting solvent. The calibration curve was found to be linear in the range of 3.1–60.0 µg/mL with regression coefficient (r2) = 0.9976. However, with acceptable r2, the calibration data’s heteroscedasticity was observed, which was further reduced using weighted linear regression with weighting factor 1/x. Finally, the method was validated concerning sensitivity, accuracy (Inter and Intraday’s % RE and RSD were 0.28, 0.65 and 1.00, 0.12 respectively), precision, recovery (89.99%, 89.09%, and 90.81% for LQC, MQC, and HQC, respectively), stability (% RSD for 30-day were 3.04 and 1.71 for LQC and HQC, respectively at −20 °C), and carry-over US-FDA guidance for Bioanalytical Method Validation for researchers in the COVID-19 pandemic crisis. Furthermore, there was no significant difference for selectivity when evaluated at LLOQ concentration of 3 µg/mL of FVIR and relative to the blank.


Sign in / Sign up

Export Citation Format

Share Document