scholarly journals Evaluation of Two Commercial Real-Time PCR Kits for Aspergillus DNA Detection in Bronchoalveolar Lavage Fluid in Patients with Invasive Pulmonary Aspergillosis

2018 ◽  
Vol 20 (3) ◽  
pp. 298-306 ◽  
Author(s):  
Julie Denis ◽  
Faezeh Forouzanfar ◽  
Raoul Herbrecht ◽  
Elise Toussaint ◽  
Romain Kessler ◽  
...  
2006 ◽  
Vol 55 (9) ◽  
pp. 1229-1235 ◽  
Author(s):  
Catharina F. M. Linssen ◽  
Jan A. Jacobs ◽  
Pieter Beckers ◽  
Kate E. Templeton ◽  
Judith Bakkers ◽  
...  

Pneumocystis jiroveci pneumonia (PCP) is an opportunistic infection affecting immunocompromised patients. While conventional diagnosis of PCP by microscopy is cumbersome, the use of PCR to diagnose PCP has great potential. Nevertheless, inter-laboratory validation and standardization of PCR assays is lacking. The aim of this study was to evaluate the inter-laboratory agreement of three independently developed real-time PCR assays for the detection of P. jiroveci in bronchoalveolar lavage fluid samples. Therefore, 124 samples were collected in three tertiary care laboratories (Leiden University Medical Center, Maastricht Infection Center and Radboud University Nijmegen Medical Centre) and were tested by both microscopy and real-time PCR. Of 41 samples positive for P. jiroveci by microscopy, 40 were positive in all three PCR assays. The remaining sample was positive in a single assay only. Out of 83 microscopy-negative samples, 69 were negative in all three PCR assays. The other 14 samples were found positive, either in all three assays (n=5), in two (n=2) or in one of the assays (n=7). The data demonstrate high inter-laboratory agreement among real-time PCR assays for the detection of P. jiroveci.


2017 ◽  
Vol 2017 ◽  
pp. 1-7 ◽  
Author(s):  
Qidong Zhuang ◽  
Hongying Ma ◽  
Yun Zhang ◽  
Lei Chen ◽  
Li Wang ◽  
...  

Background. We evaluated the utility of galactomannan (GM) in bronchoalveolar lavage fluid (BALF) for the diagnosis of invasive pulmonary aspergillosis (IPA) in nonneutropenic patients. Methods. A total of 183 patients were included in the final analysis. Bronchoscopies and the detection of GM in BALF were all performed on them. Results. Ten cases of IPA were diagnosed. ROC data demonstrated that, for diagnosing IPA, an optimal cutoff value for GM in BALF of 0.76 yielded a sensitivity of 100.0% and a specificity of 76.2%. Symptoms and radiological findings had no significant difference between proven or probable IPA group and non-IPA group. In our case-control analysis, although nine patients with false-positive results received treatment with Piperacillin/tazobactam, there was no significant difference between case and control group. Conclusions. BALF GM detection is a valuable adjunctive diagnostic tool. Our retrospective study suggests that the optimal value of GM detection in BALF is 0.76 in nonneutropenic patients.


Sign in / Sign up

Export Citation Format

Share Document