High fidelity fluid-structure interaction by radial basis functions mesh adaption of moving walls: A workflow applied to an aortic valve

2021 ◽  
Vol 51 ◽  
pp. 101327
Author(s):  
Leonardo Geronzi ◽  
Emanuele Gasparotti ◽  
Katia Capellini ◽  
Ubaldo Cella ◽  
Corrado Groth ◽  
...  
Fluids ◽  
2021 ◽  
Vol 6 (9) ◽  
pp. 314
Author(s):  
Corrado Groth ◽  
Stefano Porziani ◽  
Marco Evangelos Biancolini

Fluid structure interaction (FSI) is a complex phenomenon that in several applications cannot be neglected. Given its complexity and multi-disciplinarity the solution of FSI problems is difficult and time consuming, requiring not only the solution of the structural and fluid domains, but also the use of expensive numerical methods to couple the two physics and to properly update the numerical grid. Advanced mesh morphing can be used to embed into the fluid grid the vector fields resulting from structural calculations. The main advantage is that such embedding and the related computational costs occur only at initialization of the computation. A proper combination of embedded vector fields can be used to tackle steady and transient FSI problems by structural modes superposition, for the case of linear structures, or to impose a full non-linear displacement time history. Radial basis functions interpolation, a powerful and precise meshless tool, is used in this work to combine the vector fields and propagate their effect to the full fluid domain of interest. A review of industrial high fidelity FSI problems tackled by means of the proposed method and RBF is given for steady, transient, and non-linear transient FSI problems.


Perfusion ◽  
2021 ◽  
pp. 026765912199854
Author(s):  
Mohammad Javad Ghasemi Pour ◽  
Kamran Hassani ◽  
Morteza Khayat ◽  
Shahram Etemadi Haghighi

Background and objectives: Fluid structure interaction (FSI) is defined as interaction of the structures with contacting fluids. The aortic valve experiences the interaction with blood flow in systolic phase. In this study, we have tried to predict the hemodynamics of blood flow through a normal and stenotic aortic valve in two relaxation and exercise conditions using a three-dimensional FSI method. Methods: The aorta valve was modeled as a three-dimensional geometry including a normal model and two others with 25% and 50% stenosis. The geometry of the aortic valve was extracted from CT images and the models were generated by MMIMCS software and then they were implemented in ANSYS software. The pulsatile flow rate was used for all cases and the numerical simulations were conducted based on a time-dependent domain. Results: The obtained results including the velocity, pressure, and shear stress contours in different systolic time sequences were explained and discussed. The maximum blood flow velocity in relaxation phase was obtained 1.62 m/s (normal valve), 3.78 m/s (25% stenosed valve), and 4.73 m/s (50% stenosed valve). In exercise condition, the maximum velocities are 2.86, 4.32, and 5.42 m/s respectively. The maximum blood pressure in relaxation phase was calculated 111.45 mmHg (normal), 148.66 mmHg (25% stenosed), and 164.21 mmHg (50% stenosed). However, the calculated values in exercise situation were 129.57, 163.58, and 191.26 mmHg. The validation of the predicted results was also conducted using existing literature. Conclusions: We believe that such model are useful tools for biomechanical experts. The further studies should be done using experimental data and the data are implemented on the boundary conditions for better comparison of the results.


2018 ◽  
Vol 9 (4) ◽  
pp. 739-751 ◽  
Author(s):  
Anna Maria Tango ◽  
Jacob Salmonsmith ◽  
Andrea Ducci ◽  
Gaetano Burriesci