Determination of relative response factors for chromatographic investigations using NMR spectrometry

2009 ◽  
Vol 49 (5) ◽  
pp. 1261-1265 ◽  
Author(s):  
Gregory K. Webster ◽  
Ian Marsden ◽  
Cynthia A. Pommerening ◽  
Christina M. Tyrakowski ◽  
Brian Tobias
2011 ◽  
Vol 57 ◽  
pp. 37-41
Author(s):  
Jelena Acevska ◽  
Gjoshe Stefkov ◽  
Natalija Nakov ◽  
Marija Karapandzova ◽  
Svetlana Kulevanova ◽  
...  

In this work, a convenient method for determination of relative UV response factors (RRFs) of morphine, codeine, thebaine, oripavine, noscapine and papaverine by high performance liquid chromatography (HPLC) equipped with a diode array detector (DAD) was presented. Pholcodine was selected as the reference compound for calculating the relative response factors of the alkaloids. The separation of all seven compounds was obtained with optimized gradient elution with high pH value of the mobile phase on a reversed phase column with bidentate C18-C18 bonding technology. The RRFs of the alkaloids were determinate by three different approaches: ‘regression analysis/mass concentration’, ‘regression analysis/molar concentration’and ‘detector sensitivity’ approaches. The ‘regression analysis/molar concentration’ approach gave the accurate approximation of the exact amount of the substance that enters in the detector and the statistically relevant calculation includes several points of different concentrations (at least five), which makes this approach most advantageous one. This method is suitable for quality assessment of the standardised opium dry extract, raw opium and standardised opium tincture by quantitative analysis of not only morphine and codeine as indicated in the respective European Pharmacopoeia monographs, but as well as the major impurities that originate from opium poppy Papaver somniferum L. (Papaveraceae).


2003 ◽  
Vol 81 (2) ◽  
pp. 307-312 ◽  
Author(s):  
Huafu Wang ◽  
Gordon J Provan ◽  
Keith Helliwell

2016 ◽  
Vol 18 (6) ◽  
pp. 1895-1900 ◽  
Author(s):  
Shuyu Liu ◽  
Shangchen Yao ◽  
Hailing Zhang ◽  
Changqin Hu

2011 ◽  
Vol 8 (4) ◽  
pp. 1504-1511 ◽  
Author(s):  
Dharmendra Kushwah ◽  
Haresh B. Patel ◽  
Praveen K. Sinha ◽  
Pijush K. Jana

For the determination of accurate quantity of impurities in the samples authentic impurity standards or response factors at a given wavelength must be known. In the presented work a convenient method for determination of relative response factors of impurities has been described without using an authentic impurities standard. An approach for the determination of response factors of the impurities where impurity standard is physically not available was developed and verified using different approaches. One such method was developed and verified by RP-HPLC using Cosmosil C18 MS-II column at UV 238 nm. Two different approaches were employed and the verification of correctness of approach was done using a known related substance of known response factor.


Author(s):  
Наум Аронович Эпштейн

Представлены формулы для расчета коэффициентов относительной чувствительности RRF (relative response factors) и поправочных коэффициентов F (correction factors) примесей, а также формулы, необходимые для понимания сущности коэффициентов RRF и F. Рассмотрены основные способы определения поправочных коэффициентов и их ограничения (условия, выполнение которых необходимо для корректного определения RRF и F). Эти ограничения не отражены в Европейской фармакопее и в Фармакопее США, но от их учета зависит правильность определения значений поправочных коэффициентов. Приведены примеры и даны рекомендации для надежного определения и правильного использования поправочных коэффициентов.


Sign in / Sign up

Export Citation Format

Share Document