Development and validation of reversed phase high performance liquid chromatographic method for determination of moxonidine in the presence of its impurities

2012 ◽  
Vol 59 ◽  
pp. 151-156 ◽  
Author(s):  
Svetlana Milovanović ◽  
Biljana Otašević ◽  
Mira Zečević ◽  
Ljiljana Živanović ◽  
Ana Protić
2018 ◽  
Vol 2018 ◽  
pp. 1-5
Author(s):  
Boovizhikannan Thangabalan ◽  
Getu Kahsay ◽  
Tadele Eticha

A precise and reliable reversed-phase high-performance liquid chromatographic method with ultraviolet detection was developed and validated to determine cinitapride in human plasma. After liquid-liquid extraction, chromatographic separation was achieved on a Nucleosil C18 (25 cm × 4.6 mm, 5 µm) column with an isocratic elution consisting of 10 mM ammonium acetate (pH 5.2), methanol, and acetonitrile, 40 : 50 : 10, v/v/v. The developed method was validated as per US FDA guidelines for its linearity, selectivity, sensitivity, precision, accuracy, and stability. Satisfactory findings were obtained from the validation studies. The linearity range of the method was 1 to 35 ng/mL while the extraction recovery of cinitapride in human plasma was more than 86%. The percent coefficient of variation of both intraday and interday precision was ≤7.1%.


INDIAN DRUGS ◽  
2019 ◽  
Vol 56 (07) ◽  
pp. 43-49
Author(s):  
B.P. Manjula ◽  
V. G Joshi ◽  
Siddamsetty Ramachandra Setty ◽  
M Geetha ◽  

Tea tree oil, an active ingredient of skin, hair and nail care cosmeceuticals, has claims for topical antimicrobial, analgesic and anti-inflammatory activity. Its complex composition is governed by ISO 4730:2017. Terpinene-4-ol is the principal constituent of the oil (35% - 48%) followed by γ-terpinene (14% -28%), α-terpinene (6%-12%) and 1,8-cineole (≤15%). A reversed-phase, isocratic high performance liquid chromatographic method has been developed and validated for routine determination of tea tree oil based on1,8-cineole content in bulk and commercially available cosmeceuticals using C18 column, methanol-water (70:30 v/v) as mobile phase and flow rate of 1mL/min. UV detection was done at 200 nm. Linearity of the method was established for 20-100μL/mL (R2 = 0.9992) with LOD, LOQ values of 0.5594 μL/mL and 5.5941μL/mL respectively. The % RSD values for robustness and precision were <1% and recovery ranged between 99.09-102.96%. The method was successfully applied for determination of 1,8-cineole content in cosmeceuticals.


2008 ◽  
Vol 91 (5) ◽  
pp. 1025-1036 ◽  
Author(s):  
Mohammed Shahid Ali ◽  
Syed Rafiuddin ◽  
Muhammad Imran Munir ◽  
Mohsin Ghori ◽  
Aamer Roshanali Khatri

Abstract A reversed-phase high-performance liquid chromatographic method was developed for the simultaneous determination of benzoyl peroxide and the related compounds benzoic acid (BA), methylparaben, benzaldehyde, propylparaben, and ethyl benzoate. The compounds are separated on a column containing octadecyl silane chemically bonded to porous silica particles. The mobile phase is acetonitrilebuffer (45 + 55, v/v). Solutions are injected into the chromatographic system under isocratic conditions at a constant flow rate of 1.5 mL/min with UV detection at 235 nm. Analysis of stability samples showed rapid accumulation of BA by thermal degradation. A rationale has been established for the acceptable limit of BA in the formulation, which already contains BA (0.2) as a preservative. The proposed method is efficient and determines the active compound and 5 related compounds in a run time of 20 min. The method was validated according to the guidelines of the International Conference on Harmonization and demonstrated good agreement with the validation requirements.