scholarly journals Risk factors for early pulmonary valve replacement after valve disruption in congenital pulmonary stenosis and tetralogy of Fallot

2009 ◽  
Vol 138 (1) ◽  
pp. 103-108 ◽  
Author(s):  
Brian Kogon ◽  
Courtney Plattner ◽  
Paul Kirshbom ◽  
Kirk Kanter ◽  
Traci Leong ◽  
...  
Author(s):  
Simone Ghiselli ◽  
Cristina Carro ◽  
Nicola Uricchio ◽  
Giuseppe Annoni ◽  
Stefano M Marianeschi

Abstract OBJECTIVES Chronic pulmonary valve (PV) regurgitation is a common late sequela after repair of congenital heart diseases like tetralogy of Fallot or pulmonary stenosis, leading to right ventricular dilatation and failure and increased late morbidity and mortality. Timely reoperation may lead to a complete right ventricular recovery. An injectable PV allows pulmonary valve replacement, with or without cardiopulmonary bypass, under direct observation, thereby minimizing the impact of surgery on cardiac function. The aim of this study was to evaluate the feasibility and mid- to long-term clinical outcomes with this device. METHODS From April 2007 to October 2019, a total of 85 symptomatic patients with severe pulmonary regurgitation or pulmonary stenosis underwent pulmonary valve replacement with an injectable stented pulmonary prosthesis. Data were collected from the international proctoring registry. Mean patient age was 26.7 years. The underlying diagnosis was repaired tetralogy of Fallot in 69.4% patients; moderate or severe pulmonary regurgitation was present in 72.9%. All patients had echocardiographic scans before the operation and during the follow-up period. A total of 54.1% patients also had preoperative/postoperative cardiac magnetic resonance imaging (MRI) or catheterization; 25.9% had off-pump implants. In 53% patients, pulmonary valve replacement was associated with the repair of other cardiac defects. RESULTS Minor postoperative complications were observed in 10.8% patients. The overall mortality rate was 2.3%; mortality after valve replacement was linked to a severe cardiac insufficiency and it was not related to a prosthesis failure; 1 prosthesis was explanted from 1 patient because of endocarditis, and 6% of patients developed PV stenosis; minor complications occurred in 4.8%. The mean follow-up period was 4.8 years (2 months–12.7 years); 42% of the patients were followed for more than 5 years. Follow-up echocardiography and cardiac MRI showed a significant reduction in RV size and low gradients across the PV. CONCLUSIONS An injectable PV may be implanted without cardiopulmonary bypass and in a hybrid operating theatre with minimal surgical impact. The bioprosthesis, available up to large sizes, has a low profile, laminar flow and no risk of coronary artery compression. Incidence of endocarditis is rare. The lack of a suture ring permits the implant of a relatively larger prosthesis, thereby avoiding a right ventricular outflow tract obstruction. This device permits future percutaneous valve-in-valve procedures, if needed. Results concerning durability are encouraging, and mid- to long-term haemodynamic performance is excellent.


2012 ◽  
Vol 94 (6) ◽  
pp. 2077-2082 ◽  
Author(s):  
Annelies E. van der Hulst ◽  
Marije G. Hylkema ◽  
Hubert W. Vliegen ◽  
Victoria Delgado ◽  
Mark G. Hazekamp ◽  
...  

2016 ◽  
Vol 67 (9) ◽  
pp. 1123-1124 ◽  
Author(s):  
Jouke P. Bokma ◽  
Michiel M. Winter ◽  
Thomas Oosterhof ◽  
Hubert W. Vliegen ◽  
Arie P. van Dijk ◽  
...  

Author(s):  
Benedetta Leonardi ◽  
Camilla Calvieri ◽  
Marco Alfonso Perrone ◽  
Arianna Di Rocco ◽  
Adriano Carotti ◽  
...  

Aim: This study evaluates the risk factors associated with right ventricular (RV) dilation and dysfunction leading to pulmonary valve replacement (PVR) or adverse cardiac events in repaired Tetralogy of Fallot (rToF) patients. Methods: Data from all rToF patients who underwent magnetic resonance imaging (MRI) evaluation at our hospital between February 2007 and September 2020 were collected. Results: Three hundred and forty-two patients (60% males, 42% older than 18 years), with a median age of 16 years (IQR 13–24) at the time of MRI, were included. All patients underwent complete repair at a median age of 8 months (IQR 5–16), while palliation was performed in 56 patients (16%). One hundred and forty-four patients (42%) subsequently received pulmonary valve replacement (PVR). At the multivariate analysis, male gender was an independent predictor for significant RV dilation, RV and left ventricular (LV) dysfunction. Transventricular ventricular septal defect (VSD) closure and previous palliation significantly affected LV function and RV size, respectively. Male gender and the transventricular VSD closure were independent predictors for PVR. Conclusions: Male gender and surgical history (palliation, VSD closure approach) significantly affected the long-term outcomes in rToF patients and should be taken into consideration in the follow-up management and in PVR timing in this patient population.


2019 ◽  
Vol 10 (5) ◽  
pp. 543-551 ◽  
Author(s):  
Pasangi Madhuka Wijayarathne ◽  
Peter Skillington ◽  
Samuel Menahem ◽  
Amalan Thuraisingam ◽  
Marco Larobina ◽  
...  

Background: Following corrective surgery in infancy/childhood for tetralogy of Fallot (TOF) or its variants, patients may eventually require pulmonary valve replacement (PVR). Debate remains over which valve is best. We compared outcomes of the Medtronic Freestyle valve with that of the pulmonary allograft valve following PVR. Methods: A retrospective study was undertaken from a single surgical practice of adult patients undergoing elective PVR between April 1993 and March 2017. The choice of valve was at the surgeon’s discretion. There was a trend toward the almost exclusive use of the more readily available Medtronic Freestyle valve since 2008. Results: One hundred fifty consecutive patients undergoing 152 elective PVRs were reviewed. Their mean age was 33.8 years. Ninety-four patients had a Medtronic Freestyle valve, while 58 had a pulmonary allograft valve. There were no operative or 30-day mortality. The freedom from reintervention at 5 and 10 years was 98% and 98% for the pulmonary allograft and 99% and 89% for the Medtronic Freestyle. There was no significant difference in the rate of reintervention, though this was colored by higher pulmonary gradients across the Medtronic Freestyle despite its shorter follow-up. Conclusions: Pulmonary valve replacement following previous surgical repair of TOF or its variants was found to be safe with no significant differences in mortality or reintervention between either valve. Although the Medtronic Freestyle valve had a greater tendency toward pulmonary stenosis, additional follow-up is needed to further document its long-term outcomes.


Sign in / Sign up

Export Citation Format

Share Document