scholarly journals WITHDRAWN: Science or Art? Reproducibility of Health Preference Research

2020 ◽  
Author(s):  
Axel C. Mühlbacher
Keyword(s):  
Respiration ◽  
2021 ◽  
Vol 100 (4) ◽  
pp. 328-338
Author(s):  
Fabienne L. Huber ◽  
Michael Furian ◽  
Malcolm Kohler ◽  
Tsogyal D. Latshang ◽  
Yvonne Nussbaumer-Ochsner ◽  
...  

<b><i>Background:</i></b> In patients with obstructive sleep apnea syndrome (OSAS), the preference-based, health-related quality of life in terms of utility has not been extensively studied. <b><i>Objective:</i></b> To address this point, we compared the performance of different instruments assessing utility in patients with OSAS undergoing continuous positive airway pressure (CPAP) therapy. <b><i>Materials and Methods:</i></b> Data of 208 patients with OSAS (28 women, mean ± SE age 54.4 ± 0.7 years, apnea-hypopnea index (AHI) 51.9 ± 1.8/h, Epworth sleepiness score 13.4 ± 0.2) participating in a randomized trial of different CPAP modalities over 2 years were analyzed. Evaluations included sleep studies, Epworth sleepiness scale, and several utility instruments that measure subjective health preference on a scale ranging from 1 (most preferred and perfect health) to 0 (least preferred and very poor health). <b><i>Results:</i></b> After 2 years of CPAP therapy, the mean ± SE AHI was 6.7 ± 1.5/h and Epworth score 7.9 ± 0.4, both <i>p</i> &#x3c; 0.001 versus baseline. Baseline utilities and changes (95% confidence interval) after 2 years of CPAP therapy were EuroQol 5-dimensions 0.79 ± 0.01, 0.02 (0.00–0.05, <i>p</i> = 0.064); short-form 6-dimension medical outcome questionnaire 0.72 ± 0.01, 0.06 (0.04–0.08, <i>p</i> &#x3c; 0.001); Euro-thermometer visual analog scale 0.70 ± 0.01, 0.09 (0.07–0.12, <i>p</i> &#x3c; 0.001); time trade-off 0.82 ± 0.01, 0.03 (0.01–0.06, <i>p</i> = 0.002); and standard gamble 0.82 ± 0.01, −0.01 (−0.03 to 0.02, <i>p</i> = 0.712). <b><i>Conclusion:</i></b> The short-form 6-dimensions questionnaire, the Euro-thermometer, and the time trade-off instruments reflected the major clinical improvements in OSAS, while the EuroQoL 5-dimensions and standard gamble tests were not sensitive to CPAP effects. These results indicate that the evaluation of utility of a treatment for OSAS depends critically on the instrument used, which is important from an individual and societal perspective.


2014 ◽  
Vol 22 (2) ◽  
pp. 102-105 ◽  
Author(s):  
Carlos Delano Mundim Araújo ◽  
Daniela Francescato Veiga ◽  
Bernardo Hochman ◽  
Luiz Eduardo Felipe Abla ◽  
Neil Ferreira Novo ◽  
...  

2020 ◽  
Vol 23 ◽  
pp. S319-S320
Author(s):  
K. Myers ◽  
K. Klein ◽  
C. Mansfield ◽  
C. Poulos
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document