scholarly journals Cost-Effectiveness Analyses of an Absorbable Antibacterial Envelope for Use in Patients at Increased Risk of Cardiac Implantable Electronic Device Infection in Germany, Italy, and England

2021 ◽  
Author(s):  
Giuseppe Boriani ◽  
Charles Kennergren ◽  
Khaldoun G. Tarakji ◽  
David J. Wright ◽  
Fozia Z. Ahmed ◽  
...  
Author(s):  
Bruce L. Wilkoff ◽  
Giuseppe Boriani ◽  
Suneet Mittal ◽  
Jeanne E. Poole ◽  
Charles Kennergren ◽  
...  

Background: In the WRAP-IT trial (Worldwide Randomized Antibiotic Envelope Infection Prevention), adjunctive use of an absorbable antibacterial envelope resulted in a 40% reduction of major cardiac implantable electronic device infection without increased risk of complication in 6983 patients undergoing cardiac implantable electronic device revision, replacement, upgrade, or initial cardiac resynchronization therapy defibrillator implant. There is limited information on the cost-effectiveness of this strategy. As a prespecified objective, we evaluated antibacterial envelope cost-effectiveness compared with standard-of-care infection prevention strategies in the US healthcare system. Methods: A decision tree model was used to compare costs and outcomes of antibacterial envelope (TYRX) use adjunctive to standard-of-care infection prevention versus standard-of-care alone over a lifelong time horizon. The analysis was performed from an integrated payer-provider network perspective. Infection rates, antibacterial envelope effectiveness, infection treatment costs and patterns, infection-related mortality, and utility estimates were obtained from the WRAP-IT trial. Life expectancy and long-term costs associated with device replacement, follow-up, and healthcare utilization were sourced from the literature. Costs and quality-adjusted life years were discounted at 3%. An upper willingness-to-pay threshold of $150 000 per quality-adjusted life year was used to determine cost-effectiveness, in alignment with the American College of Cardiology/American Heart Association practice guidelines and as supported by the World Health Organization and contemporary literature. Results: The base case incremental cost-effectiveness ratio of the antibacterial envelope compared with standard-of-care was $112 603/quality-adjusted life year. The incremental cost-effectiveness ratio remained lower than the willingness-to-pay threshold in 74% of iterations in the probabilistic sensitivity analysis and was most sensitive to the following model inputs: infection-related mortality, life expectancy, and infection cost. Conclusions: The absorbable antibacterial envelope was associated with a cost-effectiveness ratio below contemporary benchmarks in the WRAP-IT patient population, suggesting that the envelope provides value for the US healthcare system by reducing the incidence of cardiac implantable electronic device infection. Registration: URL: https://www.clinicaltrials.gov . Unique identifier: NCT02277990.


2021 ◽  
Author(s):  
Jakrin Kewcharoen ◽  
Chanavuth Kanitsoraphan ◽  
Sittinun Thangjui ◽  
Thiratest Leesutipornchai ◽  
Sakditad Saowapa ◽  
...  

2021 ◽  
pp. 102568
Author(s):  
Fatehi Elzein ◽  
Eid Alsufyani ◽  
Yahya Al Hebaishi ◽  
Mohammed Mosaad ◽  
Moayad Alqurashi ◽  
...  

Circulation ◽  
2020 ◽  
Vol 142 (Suppl_3) ◽  
Author(s):  
Jakrin Kewcharoen ◽  
Chanavuth Kanitsoraphan ◽  
Sittinun Thangjui ◽  
Thiratest Leesutipornchai ◽  
Leenhapong Navaravong

Introduction: Several studies have shown inconsistent relationship between post-implantation hematoma (PH) and cardiac implantable electronic device (CIED) infection. In this study, we performed a systematic review and meta-analysis to explore the effect of PH and the risk of CIED infection. Hypothesis: PH increases the risk of CIED infection. Methods: We searched the databases of MEDLINE and EMBASE from inception to March 2020. Included studies were cohort studies, case-control studies, cross-sectional studies and randomized controlled trials that reported incidence of PH and CIED infection during the follow-up period. CIED infection was defined as either a device-related local or systemic infection. Data from each study were combined using the random-effects, generic inverse variance method of Der Simonian and Laird to calculate odds ratios (OR) and 95% confidence intervals (CI). Results: Fourteen studies from 2006 to 2018 were included, involving a total of 28,319 participants. There were 6 cohort studies, 7 case-control studies and 1 randomized controlled trial. In random-effect model, we found that PH significantly increases the risk of overall CIED infection (OR = 6.30, 95%CI: 3.87-10.24, I2=49.3%) (Figure 1). There was no publication bias observed in the funnel plot as well as no small-study effect observed in Egger’s test. Conclusions: Our meta-analysis demonstrated that PH significantly increases the risk of CIED infection. Precaution should be taken to during device implantation to reduce PH and subsequent CIED infection.


2017 ◽  
Vol 84 (12 suppl 3) ◽  
pp. 47-53 ◽  
Author(s):  
Cameron T. Lambert ◽  
Khaldoun G. Tarakji

2020 ◽  
Vol 111 ◽  
pp. 65-79
Author(s):  
Shantanu P. Nikam ◽  
Karissa Nettleton ◽  
Jeffrey I. Everitt ◽  
Hazel A. Barton ◽  
Matthew L. Becker

Sign in / Sign up

Export Citation Format

Share Document