Behaviour of fibre reinforced cementitious matrix strengthened concrete columns under eccentric compression loading

2014 ◽  
Vol 54 ◽  
pp. 947-954 ◽  
Author(s):  
Tomasz Trapko
2020 ◽  
Vol 23 (10) ◽  
pp. 2018-2029
Author(s):  
Hongbing Li ◽  
Fangbo Wu ◽  
Liangtao Bu ◽  
Yong Liu ◽  
Jiang Yao

In this study, the mechanical properties and failure characteristics of steel reactive powder concrete columns with different strength grades were investigated through compression testing. Six steel reactive powder concrete columns were tested; three columns underwent axial compression testing and three columns underwent eccentric compression testing. The results of the axial compression testing showed that steel and reactive powder concrete could work cooperatively at the initial stage, and the final column failure mode was primarily splitting failure at the end of the column, with the formation of a main crack in the longitudinal direction extending to the middle of the column. The results of the eccentric compression testing showed that the eccentrically loaded steel reactive powder concrete columns had comparatively strong deformability. The columns presented ductile failure mode under the eccentric load with 0.2 eccentricity. The final failure of the column involved a sudden increase in the horizontal crack width on the tension side, the steel flange on the tension side reached the yield state, the reactive powder concrete in the middle of the compressive side was crushed, and the reactive powder concrete surface layer burst open and partially spalled off. According to the test results and with reference to the relevant standards, equations for calculating the approximate ultimate bearing capacities of axially and eccentrically compressed reactive powder concrete columns were proposed.


2011 ◽  
Vol 71-78 ◽  
pp. 4203-4206
Author(s):  
Le Zhou ◽  
Hong Tao Liu

For the further study of bearing compressive capacity of GFRP tube filled with SHC(steel-reinforced high-strength concrete)columns subjected to eccentric compression, and analysis its whole bearing compressive process under eccentric compression. Based on the flat section assumption finite strip method, the calculating program of bearing eccentric compressive capacity of GFRP tube filled with SHC columns is proposed according to existing retrofit theory and related technical procedures. The relation curves of load-deformation is gotten using this calculating program, at the same time it can get the effect curves of concrete strength, slenderness ratio, eccentricity and containing bone rate to load-deformation. Calculations show that the ultimate bearing compressive capacity of composite column decreases with the increase of slenderness ratio, and elastic stage of component curve gradually shortens and stiffness gradually loses; The ultimate bearing compressive capacity of composite columns decreases with the increase of eccentricity; component ductility improves; the ultimate bearing compressive capacity of composite columns increases with the increase of concrete strength. The calculated results agree well with the experimental results and this study provides a basis for practical design.


Sign in / Sign up

Export Citation Format

Share Document