Free vibrations of rigidly fixed electro-magneto non-local generalized thermoelastic cylinder with voids material

Author(s):  
Sita Ram Sharma ◽  
Jai Chand Mehalwal ◽  
Dinesh Kumar Sharma
Author(s):  
Mehdi Masoumi ◽  
Masoud Masoumi

In this article, the effects of some parameters, including rotary inertia, non-local parameter, and length-to-thickness ratio, on natural frequencies are studied for both classical and non-local theories. For Timoshenko beam, the equations of motion and the boundary conditions are derived from Hamilton’s principle and then non-local constitutive equations of Eringen are employed to altogether formulate the problem. Afterward, obtained governing equations are used to study the free vibrations of a Timoshenko’s simply supported nano-beam. And finally, the effects of above-mentioned parameters on estimated frequencies in classical and non-local elasticity theories are investigated. Results show that the discrepancy between the frequencies of higher-order vibration modes obtained from two theories increases and also significant reductions in natural frequencies occur when the rotary inertia is considered in the computations.


Author(s):  
Zhifeng Shao

Recently, low voltage (≤5kV) scanning electron microscopes have become popular because of their unprecedented advantages, such as minimized charging effects and smaller specimen damage, etc. Perhaps the most important advantage of LVSEM is that they may be able to provide ultrahigh resolution since the interaction volume decreases when electron energy is reduced. It is obvious that no matter how low the operating voltage is, the resolution is always poorer than the probe radius. To achieve 10Å resolution at 5kV (including non-local effects), we would require a probe radius of 5∽6 Å. At low voltages, we can no longer ignore the effects of chromatic aberration because of the increased ratio δV/V. The 3rd order spherical aberration is another major limiting factor. The optimized aperture should be calculated as


Author(s):  
Zhifeng Shao ◽  
A.V. Crewe

For scanning electron microscopes, it is plausible that by lowering the primary electron energy, one can decrease the volume of interaction and improve resolution. As shown by Crewe /1/, at V0 =5kV a 10Å resolution (including non-local effects) is possible. To achieve this, we would need a probe size about 5Å. However, at low voltages, the chromatic aberration becomes the major concern even for field emission sources. In this case, δV/V = 0.1 V/5kV = 2x10-5. As a rough estimate, it has been shown that /2/ the chromatic aberration δC should be less than ⅓ of δ0 the probe size determined by diffraction and spherical aberration in order to neglect its effect. But this did not take into account the distribution of electron energy. We will show that by using a wave optical treatment, the tolerance on the chromatic aberration is much larger than we expected.


1998 ◽  
Vol 08 (PR8) ◽  
pp. Pr8-309-Pr8-316 ◽  
Author(s):  
Y. Z. Povstenko
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document