scholarly journals Tracking system for magnetic foreign bodies localization using a portable device

2021 ◽  
Vol 18 ◽  
pp. 100275
Author(s):  
Marcos Rogozinski ◽  
Carlos Roberto Hall Barbosa ◽  
Elisabeth Costa Monteiro
1998 ◽  
Vol 35 (4) ◽  
pp. 271-378 ◽  
Author(s):  
D JOHNSON ◽  
V CONDON

2013 ◽  
Vol 83 (2) ◽  
pp. 122-128 ◽  
Author(s):  
Cécile Renaud ◽  
Jacques Berger ◽  
Arnaud Laillou ◽  
Sylvie Avallone

Vitamin A deficiency is still one of the major public health problems in least developed countries. Fortification of vegetable oils is a strategy implemented worldwide to prevent this deficiency. For a fortification program to be effective, regular monitoring is necessary to control food quality in the producing units. The reference methods for vitamin A quantification are expensive and time-consuming. A rapid method should be useful for regular assessment of vitamin A in the oil industry. A portable device was compared to high-performance liquid chromatography (HPLC) for three plant oils (rapeseed, groundnut, and soya). The device presented a good linearity from 3 to 30 mg retinol equivalents per kg (mg RE.kg- 1). Its limits of detection and quantification were 3 mg RE.kg- 1 for groundnut and rapeseed oils and 4 mg RE.kg- 1 for soya oil. The intra-assay precision ranged from 1.48 % to 3.98 %, considered satisfactory. Accuracy estimated by the root mean squares error ranged from 3.99 to 5.49 and revealed a lower precision than HPLC (0.4 to 2.25). Although it offers less precision than HPLC, the device estimates quickly the vitamin A content of the tested oils from 3 or 4 to 15 mg RE.kg- 1.


Swiss Surgery ◽  
2001 ◽  
Vol 7 (3) ◽  
pp. 139-140 ◽  
Author(s):  
Halkic ◽  
Wisard ◽  
Abdelmoumene ◽  
Vuilleumier

All manner of foreign bodies have been extracted from the bladder. Introduction into the bladder may be through self-insertion, iatrogenic means or migration from adjacent organs. Extraction should be tailored according to the nature of the foreign body and should minimise bladder and urethral trauma. We report a case of a bullet injury to the bladder, which finally presented as a gross hematuria after remaining asymptomatic for four years. We present here an alternative to suprapubic cystostomy with a large bladder foreign body treated via a combined transurethral unroofing followed by removal using a grasper passed through a suprapubic laparoscopic port.


Author(s):  
Paul A. Wetzel ◽  
Gretchen Krueger-Anderson ◽  
Christine Poprik ◽  
Peter Bascom

1993 ◽  
Vol 9 (2) ◽  
pp. 96-100 ◽  
Author(s):  
Thomas Payne ◽  
Susan Kanvik ◽  
Richard Seward ◽  
Doug Beeman ◽  
Angela Salazar ◽  
...  

2018 ◽  
Vol 2 (1) ◽  
Author(s):  
Fatima Ameen ◽  
Ziad Mohammed ◽  
Abdulrahman Siddiq

Tracking systems of moving objects provide a useful means to better control, manage and secure them. Tracking systems are used in different scales of applications such as indoors, outdoors and even used to track vehicles, ships and air planes moving over the globe. This paper presents the design and implementation of a system for tracking objects moving over a wide geographical area. The system depends on the Global Positioning System (GPS) and Global System for Mobile Communications (GSM) technologies without requiring the Internet service. The implemented system uses the freely available GPS service to determine the position of the moving objects. The tests of the implemented system in different regions and conditions show that the maximum uncertainty in the obtained positions is a circle with radius of about 16 m, which is an acceptable result for tracking the movement of objects in wide and open environments.


Sign in / Sign up

Export Citation Format

Share Document