Functional polymorphism in Z-DNA–forming motif of promoter of SLC11A1 gene and type 1 diabetes in Japanese subjects: Association study and meta-analysis

Metabolism ◽  
2005 ◽  
Vol 54 (5) ◽  
pp. 628-633 ◽  
Author(s):  
Masanori Nishino ◽  
Hiroshi Ikegami ◽  
Tomomi Fujisawa ◽  
Yoshihiko Kawaguchi ◽  
Yumiko Kawabata ◽  
...  
2009 ◽  
Vol 41 (6) ◽  
pp. 703-707 ◽  
Author(s):  
Jeffrey C Barrett ◽  
◽  
David G Clayton ◽  
Patrick Concannon ◽  
Beena Akolkar ◽  
...  

2008 ◽  
Vol 40 (12) ◽  
pp. 1399-1401 ◽  
Author(s):  
Jason D Cooper ◽  
Deborah J Smyth ◽  
Adam M Smiles ◽  
Vincent Plagnol ◽  
Neil M Walker ◽  
...  

2020 ◽  
Author(s):  
Anthony Pease ◽  
Clement Lo ◽  
Arul Earnest ◽  
Velislava Kiriakova ◽  
Danny Liew ◽  
...  

<b>Background: </b>Time-in-range is a key glycaemic metric, and comparisons of management technologies for this outcome are critical to guide device selection. <p><b> </b></p> <p><b>Purpose: </b>We conducted a systematic review and network meta-analysis to compare and rank technologies for time in glycaemic ranges.</p> <p> </p> <p><b>Data sources: </b>We searched All Evidenced Based Medicine Reviews, CINAHL, EMBASE, MEDLINE, MEDLINE In-Process and other non-indexed citations, PROSPERO, PsycINFO, PubMed, and Web of Science until 24 April, 2019.</p> <p> </p> <p><b>Study selection: </b>We included randomised controlled trials <u>></u>2 weeks duration comparing technologies for management of type 1 diabetes in adults (<u>></u>18 years of age), excluding pregnant women. </p> <p> </p> <p><b>Data extraction: </b>Data were extracted using a predefined template. Outcomes were percent time with sensor glucose levels 3.9–10.0mmol/l (70–180mg/dL), >10.0mmol/L (180mg/dL), and <3.9mmol/L (70mg/dL). </p> <p><b> </b></p> <p><b>Data synthesis: </b>We identified 16,772 publications, of which 14 eligible studies compared eight technologies comprising 1,043 participants. Closed loop systems lead to greater percent time-in-range than any other management strategy and was 17.85 (95% predictive interval [PrI] 7.56–28.14) higher than usual care of multiple daily injections with capillary glucose testing. Closed loop systems ranked best for percent time-in-range or above range utilising surface under the cumulative ranking curve (SUCRA–98.5 and 93.5 respectively). Closed loop systems also ranked highly for time below range (SUCRA–62.2). </p> <p><b> </b></p> <p><b>Limitations: </b>Overall risk of bias ratings were moderate for all outcomes. Certainty of evidence was very low.</p> <p><b> </b></p> <p><b>Conclusions: </b>In the first integrated comparison of multiple management strategies considering time-in-range, we found that the efficacy of closed loop systems appeared better than all other approaches. </p>


Sign in / Sign up

Export Citation Format

Share Document