scholarly journals Microvascular blood flow monitoring with laser speckle contrast imaging using the generalized differences algorithm

2015 ◽  
Vol 98 ◽  
pp. 54-61 ◽  
Author(s):  
Anne Humeau-Heurtier ◽  
Guillaume Mahé ◽  
Pierre Abraham
2016 ◽  
Vol 56 (3-4) ◽  
pp. 87-96 ◽  
Author(s):  
Rikard Ambrus ◽  
Rune B. Strandby ◽  
Lars Bo Svendsen ◽  
Michael P. Achiam ◽  
John F. Steffensen ◽  
...  

Background/Aims: Microvascular blood flow is essential for healing and predicts surgical outcome. The aim of the current study was to investigate the relation between fluxes measured with the laser speckle contrast imaging (LSCI) technique and changes in absolute blood flow. In addition, we studied the reproducibility of the LSCI technique when assessing the intra-abdominal microcirculation of the pig. Methods: During trial 1, a fish gill arch was mechanically perfused with heparinized fish blood under controlled stepwise-altered flow rates alongside mechanically induced movement artefacts. The microcirculation of the fish gill was simultaneously assessed with the LSCI technique. In trial 2, microcirculation was measured in the stomach, liver, and small intestine of 10 pigs by two observers. Results: A linear correlation was observed between flux and volumetric flow. During conditions of no volumetric flow, the high recording speed with the LSCI technique registered the movement artefacts as flow signals. The LSCI measurements showed good correlation and agreement between the two observers when assessing microcirculation in the stomach, liver, and small intestine (r2 = 0.857, 0.956, and 0.946; coefficients of variation = 6.0, 3.2, and 6.4%, respectively). Conclusion: Due to the non-contact and real-time assessment over large areas, LSCI is a promising technique for the intraoperative assessment of intra-abdominal microcirculation. A linear correlation between flux and volumetric flow was found, in accordance with previous experimental studies. However, movement artefacts affect flux measurements, and the choice of the sampling speed must be made with care, depending on the given setting.


Burns ◽  
2016 ◽  
Vol 42 (3) ◽  
pp. 648-654 ◽  
Author(s):  
Robin Mirdell ◽  
Fredrik Iredahl ◽  
Folke Sjöberg ◽  
Simon Farnebo ◽  
Erik Tesselaar

2021 ◽  
Vol 10 (1) ◽  
Author(s):  
Dong-Yu Li ◽  
Qing Xia ◽  
Ting-Ting Yu ◽  
Jing-Tan Zhu ◽  
Dan Zhu

AbstractLaser speckle contrast imaging (LSCI) is a powerful tool to monitor blood flow distribution and has been widely used in studies of microcirculation, both for animal and clinical applications. Conventionally, LSCI usually works on reflective-detected mode. However, it could provide promising temporal and spatial resolution for in vivo applications only with the assistance of various tissue windows, otherwise, the overlarge superficial static speckle would extremely limit its contrast and resolution. Here, we systematically investigated the capability of transmissive-detected LSCI (TR-LSCI) for blood flow monitoring in thick tissue. Using Monte Carlo simulation, we theoretically compared the performance of transmissive and reflective detection. It was found that the reflective-detected mode was better when the target layer was at the very surface, but the imaging quality would rapidly decrease with imaging depth, while the transmissive-detected mode could obtain a much stronger signal-to-background ratio (SBR) for thick tissue. We further proved by tissue phantom, animal, and human experiments that in a certain thickness of tissue, TR-LSCI showed remarkably better performance for thick-tissue imaging, and the imaging quality would be further improved if the use of longer wavelengths of near-infrared light. Therefore, both theoretical and experimental results demonstrate that TR-LSCI is capable of obtaining thick-tissue blood flow information and holds great potential in the field of microcirculation research.


2011 ◽  
Vol 300 (2) ◽  
pp. F319-F329 ◽  
Author(s):  
Niels-Henrik Holstein-Rathlou ◽  
Olga V. Sosnovtseva ◽  
Alexey N. Pavlov ◽  
William A. Cupples ◽  
Charlotte Mehlin Sorensen ◽  
...  

Tubuloglomerular feedback (TGF) has an important role in autoregulation of renal blood flow and glomerular filtration rate (GFR). Because of the characteristics of signal transmission in the feedback loop, the TGF undergoes self-sustained oscillations in single-nephron blood flow, GFR, and tubular pressure and flow. Nephrons interact by exchanging electrical signals conducted electrotonically through cells of the vascular wall, leading to synchronization of the TGF-mediated oscillations. Experimental studies of these interactions have been limited to observations on two or at most three nephrons simultaneously. The interacting nephron fields are likely to be more extensive. We have turned to laser speckle contrast imaging to measure the blood flow dynamics of 50–100 nephrons simultaneously on the renal surface of anesthetized rats. We report the application of this method and describe analytic techniques for extracting the desired data and for examining them for evidence of nephron synchronization. Synchronized TGF oscillations were detected in pairs or triplets of nephrons. The amplitude and the frequency of the oscillations changed with time, as did the patterns of synchronization. Synchronization may take place among nephrons not immediately adjacent on the surface of the kidney.


2018 ◽  
Vol 12 (1) ◽  
pp. e201800100 ◽  
Author(s):  
Wenzhi Lv ◽  
Yang Wang ◽  
Xiao Chen ◽  
Xiaoxi Fu ◽  
Jinling Lu ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document